TT
TT
Tel:el:
el:el:
el: 01978 262255 01978 262255
01978 262255 01978 262255
01978 262255 Fax: 01978 262233Fax: 01978 262233
Fax: 01978 262233Fax: 01978 262233
Fax: 01978 262233
PRPR
PRPR
PROO
OO
OTRANTRAN
TRANTRAN
TRAN PR3200 DIFFERENTIAL PRESSURE TRANSMITTERPR3200 DIFFERENTIAL PRESSURE TRANSMITTER
PR3200 DIFFERENTIAL PRESSURE TRANSMITTERPR3200 DIFFERENTIAL PRESSURE TRANSMITTER
PR3200 DIFFERENTIAL PRESSURE TRANSMITTER
©
ACCURATE AT VERY WIDE DP RANGEACCURATE AT VERY WIDE DP RANGE
ACCURATE AT VERY WIDE DP RANGEACCURATE AT VERY WIDE DP RANGE
ACCURATE AT VERY WIDE DP RANGE
HIGH STABILITY and REPEATABILITYHIGH STABILITY and REPEATABILITY
HIGH STABILITY and REPEATABILITYHIGH STABILITY and REPEATABILITY
HIGH STABILITY and REPEATABILITY
WET / WET OPERATIONWET / WET OPERATION
WET / WET OPERATIONWET / WET OPERATION
WET / WET OPERATION
4-20mA TWO-WIRE OUTPUT4-20mA TWO-WIRE OUTPUT
4-20mA TWO-WIRE OUTPUT4-20mA TWO-WIRE OUTPUT
4-20mA TWO-WIRE OUTPUT
ZERO + SPAN ADJUSTMENT ON-SITEZERO + SPAN ADJUSTMENT ON-SITE
ZERO + SPAN ADJUSTMENT ON-SITEZERO + SPAN ADJUSTMENT ON-SITE
ZERO + SPAN ADJUSTMENT ON-SITE
RANGES 250mbarDP to 200barDPRANGES 250mbarDP to 200barDP
RANGES 250mbarDP to 200barDPRANGES 250mbarDP to 200barDP
RANGES 250mbarDP to 200barDP
UNI + BI-DIRECTIONAL OPERATIONUNI + BI-DIRECTIONAL OPERATION
UNI + BI-DIRECTIONAL OPERATIONUNI + BI-DIRECTIONAL OPERATION
UNI + BI-DIRECTIONAL OPERATION
DESCRIPTIONDESCRIPTION
DESCRIPTIONDESCRIPTION
DESCRIPTION
The PR3200 Differential Pressure Transmitter uses two matched ceramic pressure diaphragms, offering high
stability and performance with true wet/wet operation, suitable for use with all liquids and gasses compatible with
stainless steel and alumina. Flush diaphragm models are available with integral or remote pressure diaphragms for
hygienic applications.
Applications include flow measurement with pitot tubes, orifice plates and mass flow meters, plus static differential
pressure measurement and control in combustion chambers and clean rooms, also condition monitoring and filter
monitoring in high pressure hydraulic systems or any application on liquid or gas requiring reliable differential
pressure measurement.
Electrical connection is DIN plug and socket, access to zero and span adjustment is made by removing top plate
for easy on-site adjustment.
Pressure connection as standard is via two ¼"BSP female connections.
Mounting Plate available for stand-pipe or bulk-head mounting.
Ranges available from 0-250mbarDP to 0-200barDP.
TT
TT
Tel:el:
el:el:
el: 01978 262255 01978 262255
01978 262255 01978 262255
01978 262255 Fax: 01978 262233Fax: 01978 262233
Fax: 01978 262233Fax: 01978 262233
Fax: 01978 262233
ellison sensors internationalellison sensors international
ellison sensors internationalellison sensors international
ellison sensors international
Sensor House, Wrexham Technology Park, Wrexham, LL 13 7YP, Wales, U.K.
PRPR
PRPR
PROO
OO
OTRANTRAN
TRANTRAN
TRAN
SPECIFICATIONSPECIFICATION
SPECIFICATIONSPECIFICATION
SPECIFICATION
DIMENSIONS / WIRING DETAILSDIMENSIONS / WIRING DETAILS
DIMENSIONS / WIRING DETAILSDIMENSIONS / WIRING DETAILS
DIMENSIONS / WIRING DETAILS
ORDERING INFORMATIONORDERING INFORMATION
ORDERING INFORMATIONORDERING INFORMATION
ORDERING INFORMATION
STATE MODEL NUMBER AND PRESSURE RANGE REQUIRED:-
ie: PR3200 0-10mbarDP
PR3200 DIFFERENTIAL PRESSURE TRANSMITTERPR3200 DIFFERENTIAL PRESSURE TRANSMITTER
PR3200 DIFFERENTIAL PRESSURE TRANSMITTERPR3200 DIFFERENTIAL PRESSURE TRANSMITTER
PR3200 DIFFERENTIAL PRESSURE TRANSMITTER
©
D.P. PRESSURE RANGESD.P. PRESSURE RANGES
D.P. PRESSURE RANGESD.P. PRESSURE RANGES
D.P. PRESSURE RANGES
0 - 250 mbar
0 - 500 mbar
0 - 750 mbar
0 - 1 bar
0 - 2 bar
0 - 4 bar
0 - 10 bar
0 - 20 bar
0 - 40 bar
0 - 100 bar
0 - 200 bar
TRANSMITTER WIRING DIAGRAMTRANSMITTER WIRING DIAGRAM
TRANSMITTER WIRING DIAGRAMTRANSMITTER WIRING DIAGRAM
TRANSMITTER WIRING DIAGRAM
LOAD DRIVING CHARTLOAD DRIVING CHART
LOAD DRIVING CHARTLOAD DRIVING CHART
LOAD DRIVING CHART
MODEL NO. DESCRIPTION
PR3200 DP Transmitter 0-250mbar to
0-200 bar
PR3200/MP Mounting Angle Plate
Reverse polarity.......................Protected
Load driving capability..............1150 @ 36Vdc
Output short circuit (to ground) No damage
Insulation resistance................ 100M @ 100Vdc elec conn to case
Response time (63%).............. 1.5mS
Adjustment............................... ±10%FSO Zero and Span
ENVIRONMENTALENVIRONMENTAL
ENVIRONMENTALENVIRONMENTAL
ENVIRONMENTAL
Pressure media....................... Compatible with alumina +304 S.S
Operating temperature range.. -20 to +85 °C
Storage temperature range......-40 to +90°C
Thermal effect Zero................. <±0.03% FSO/°C
Thermal sensistivity................. <±0.03% FSO/°C
Vibration tolerance................... 10g’s to 50Hz
Mechanical shock tolerance.... 15g@s (11mS)
Operating humidity................... 95% RH
PHYSICALPHYSICAL
PHYSICALPHYSICAL
PHYSICAL
Pressure connections..............¼" BSP female x 2
Electrical connection................ DIN plug + socket to DIN43650
Mounting...................................Via mounting plate (optional extra)
Enclosure rating....................... IP65
Natural frequency.................... 10 Khz (min)
Weight...................................... 780 grams
Materials...................................300 series stain’stl body/
connector alumina diaphragm
INPUTINPUT
INPUTINPUT
INPUT
Pressure ranges...................................0-250 mbarDP
to 0-200 barDP
Pressure reference...............................Differential
Operation mode.....................................Uni or Bi-directional
Static pressure max..............................4 x range (max)
Common mode pressure......................4 x range (max)
OUTPUTOUTPUT
OUTPUTOUTPUT
OUTPUT
Span......................................................4-20 mA
Type......................................................2 wire
ACCURACYACCURACY
ACCURACYACCURACY
ACCURACY
Zero offset.............................................<±1% FSO
Span tolerance......................................<±1% FSO
Combined non-linearity / hysteresis .... <±0.3% FSO
Repeatability..........................................<±0.1% FSO
Long term stability.................................<±0.2% FSO / 6 months
Common mode pressure error ............<±2% / 4 x DP range
ELECTRICALELECTRICAL
ELECTRICALELECTRICAL
ELECTRICAL
Supply voltage.......................................13-36Vdc
Supply voltage effects...........................3µA/V