Features DIN Rail Series * Universal AC input (85-264VAC) * Long 7 year warranty * Protections: SCP, OVP, OCP, OTP * 100% full load burn-in test * DC OK indicator LED with relay contacts * cooling by free air convection, 5000m operation * UL, CSA & CE certified with CB report Description This DIN-rail mounted power supply uses high reliability components to give a long, trouble-free life The power supply can be end mounted to save space or side mounted for use in low-profile cabinets. Relay contacts simplify DC OK monitoring and the units can deliver 80W start-up power. The REDIN series is fully certified for industrial use and carries a 7-year warranty. AC/DC Converter REDIN60 60 Watt DIN-Rail Power Supply Selection Guide Part Input Output Output Rated Efficiency Max. Number Voltage Range Voltage Trimming Voltage Current typ. Capacitive Load [VAC] [VDC] [VDC] [A][%] [F] REDIN60-1285-264 12 12-15 5.0 85 18800 REDIN60-2485-264 24 24-28 2.5 86 4700 Specifications (measured at Ta= 25C, 230VAC, full load and after warm up) BASIC CHARACTERISTICS Parameter Condition Min. Input Voltage Range all operating conditions 85VAC max. Input Voltage max. 1 second Output Voltage Adjustment (Factory Setting) (1) Typ. Max. 264VAC 300VAC 375VDC REDIN60-12 REDIN60-24 12-15VDC (12V5%) 24-28VDC (24V5%) Input Current full load, 115VAC full load, 230VAC 1.8A 1.0A Inrush Current cold start at 25C, 115VAC cold start at 25C, 230VAC 40A 60A standard (with Relay) /NR option (no Relay) <1000mW <500mW No Load Power Consumption Start up time cold start, 230VAC 500ms Rise time cold start, 230VAC 20ms Hold-up time full load, 115VAC full load, 230VAC 20ms 50ms Input Frequency Range 47Hz Operating Frequency Range Output Ripple and Noise (2) Over Load Capability 1000ms E224736 CB-Report UL60950-1 certified IEC/EN60950-1 certified CSA C22.2 No. 60950-1-07 certified UL508 certified CAN/CSA-C22.2 No. 107.1-01 certified EN55024 certified EN55032 certified 63Hz 65kHz REDIN60-12 REDIN60-24 all operating conditions 60mVp-p 75mVp-p 140% for 5 seconds max. Notes: Note1: For more details refer to "Vadj. Derating" graph Note2: Ripple and Noise are measured at 20MHz bandwidth by using a 12" twisted pair-wire terminated with 0.1F & 47F parallel capacitor continued on next page www.recom-power.com REV.: 9/2019 PDR-1 REDIN60 AC/DC Converter Series Specifications (measured at Ta= 25C, 230VAC, full load and after warm up) Efficiency vs. Load REDIN60-12 REDIN60-24 90 90 80 80 70 70 Efficiency [%] 100 Efficiency [%] 100 60 50 40 30 10 0 0 10 20 30 40 50 60 70 80 50 40 30 85VAC 115VAC 230VAC 264VAC 20 60 85VAC 115VAC 230VAC 264VAC 20 10 90 100 0 0 10 20 Vadj. Derating Output Current [%] Output Load [%] 30 40 50 60 70 80 90 100 Output Load [%] 100 80 60W max. 12 (24) Vadj. 15 (28) Output Voltage [VDC] REGULATION Parameter Condition Value Line Regulation 0.1% typ. / 1% max. Load Regulation Transient Response (3) 0.1% typ. / 1% max. REDIN60-12 (step load change: 2.5A - 5.0A) REDIN60-24 (step load change: 1.25A - 2.5A) 5% typ. 5% typ. 100Hz & 1kHz 50% duty 0.5A / s Dwell Time Slew Rate Notes: Note3: Transient Response + E-CAP loading 3300F. Other specs with resistive load only PROTECTION Parameter Condition Value Input Fuse T2.5A, slow blow type auto-recovery after fault condition, Hiccup Mode Short Circuit Protection (SCP) Over Voltage Protection (OVP) REDIN60-12 REDIN60-24 18VDC max., shut-down latch-off o/p voltage, re-power on to recover 35VDC max., shut-down latch-off o/p voltage, re-power on to recover Over Voltage Category OVCII Over Current Protection (OCP) Over Temperature Protection (OTP) Isolation Voltage Isolation Resistance Leakage Current Power OK LED www.recom-power.com 150% typ., auto-recovery after fault condition is removed detect on inside ambient I/P to O/P I/P to FG O/P to FG 500VDC, 70% RH, I/P to O/P; I/P to FG; O/P to FG tested for 1 minute 240VAC 105C5%, shut-down latch-off o/p voltage, re-power on to recover 3.75kVAC 1.88kVAC 0.5kVAC 100MW min. >1mA Relay Contacts LED/Relay 1A, 30VDC / 120VAC ON if Vout = 11-16V (12V) / 22-30V (24V) REV.: 9/2019 PDR-2 REDIN60 AC/DC Converter Series Specifications (measured at Ta= 25C, 230VAC, full load and after warm up) ENVIRONMENTAL Parameter Operating Temperature Range Operating Humidity Condition Value with derating -20C to +70C (see graph) non-condensing 20% - 90%RH Vibration 10-500Hz 2G, 60min. Shock 3 times each axis 10G / 11ms, along X, Y and Z axis Altitude see derating graph 5000m MTBF (+25C) according to MIL-HDBK-217F, 115VAC, 60Hz, 75% load 200 x 10 hours Design Lifetime (+40C) 87.6 x 10 hours Derating Graph Vin >100VAC 100 100 90 90 80 80 70 70 65 60 Output Load [%] Output Load [%] Vin 100VAC 60 50 45 40 24VDC 12VDC 30 50 40 20 20 10 10 0 -40 -30 -20 -10 0 24VDC 12VDC 30 10 20 30 40 50 60 55 70 0 -40 -30 -20 -10 80 Ambient Temperature [C] 0 10 20 30 40 50 60 55 70 80 Ambient Temperature [C] Typical Characteristics REDIN60-24 100 100 90 90 80 80 70 70 Output Load [%] Output Load [%] REDIN60-12 60 50 35C 50C (60W) 40 30 60 50 40 30 20 20 10 10 0 0 1000 2000 3000 4000 5000 6000 Operating Altitude [m] www.recom-power.com 35C 55C (60W) 0 0 1000 2000 3000 4000 5000 6000 Operating Altitude [m] REV.: 9/2019 PDR-3 REDIN60 AC/DC Converter Series Specifications (measured at Ta= 25C, 230VAC, full load and after warm up) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Information Technology Equipment - General Requirments for Safety Industrial Control Equipment UL60950-1 2nd Edition 2011 CAN/CSA-C22.2 No. 60950-1-07 2nd Edition 2011 E224736-A23 CAN/CSA-C22.2 No. 107.1-01, 3rd Edition 2011 UL508, 17th Edition 2013 E470721 Information Technology Equipment - General Requirments for Safety EAC Standard EN60950-1:2006 + A2:2013 IEC60950-1:2005 2nd Edition + A1:2009 E224736-A23 RU-AT.37.02367 TP TC 004/2011 RoHS2 RoHs 2011/65/EU EMC Compliance Report / Condition Standard / Criterion Electromagnetic compatibility of multimedia equipment - Emission Requirements EN55032:2015 Information technology equipment- Immunity characteristicsLimits and methods of measurement ESD Electrostatic discharge immunity test EN55024:2010 + A1:2015 Air +/-2, 4, 8kV, Contact +/-2, 4kV Radiated, radio-frequency, electromagnetic field immunity test Fast Transient and Burst Immunity Surge Immunity Immunity to conducted disturbances, induced by radio-frequency fields 3V/m IEC61000-4-2:2008; Criteria A IEC61000-4-3:2006 + A1:2007 + A2:2010; Criteria A AC Power Port: +/-1.0kV IEC61000-4-4:2012; Criteria A AC Power Port: L-N +/-0.5, 1, 2kV L-PE, N-PE +/-0.5, 1, 2, 4kV IEC61000-4-5:2014; Criteria A AC Power Port 3V IEC61000-4-6:2013; Criteria A Power Magnetic Field Immunity 50Hz, 1A/m IEC61000-4-8:2009; Criteria A Voltage Dips and Interruptions Voltage Dips >95% Voltage Dips 30% Voltage Interruptions > 95% IEC61000-4-11:2004; Criteria A IEC61000-4-11:2004; Criteria A IEC61000-4-11:2004; Criteria B Limits of Harmonic Current Emissions EN61000-3-2:2014, Class A Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013 Limitations on the amount of electromagnetic intererence allowed from digital and electronic devices 47 CFR FCC Part 15 Subpart B 2010-01-07, Class B DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Material case Value plastic, (UL94V-0) Dimension (WxHxD) 45.1 x 92.0 x 101.2mm Weight 332g Dimension Drawing (mm) 101.2 +V -V DC OK DC OK 92.0 TRIM Front Side FG N L 45.1 continued on next page www.recom-power.com REV.: 9/2019 DIN-RAIL mounting bracket PDR-4 92 +V -V REDIN60 DC OK Front Side DC OK FG N L 92.0 TRIM AC/DC Converter Series 45.1 Front Side 230VAC, full load and after warm up) Specifications (measured at Ta= 25C, FG N L Dimension Drawing (mm) 45.1 DIN-RAIL mounting bracket (75mm) included 7.50.2 DIN-RAIL mounting750.3 bracket (75mm) included 6.30.2 750.3 350.1 7.50.2 25.0 6.30.2 350.1 25.0 180.2 10.05 180.2 25.0 10.05 25.0 INSTALLATION END MOUNTING SIDE MOUNTING END MOUNTING +V +V -V -V SIDE MOUNTING DC DCOKOK Front Side Front Side FG N L FG N L End Latch Release Mounting Instruction Side Latch Release End Latch Release Tolerance: 0.5mm Side Latch Release Tolerance: 0.5mm Releasing Mounting 1 Front Side Front Side FG N L FG N L 2 2 Click" 1 continued on next page www.recom-power.com REV.: 9/2019 PDR-5 REDIN60 AC/DC Converter Series Specifications (measured at Ta= 25C, 230VAC, full load and after warm up) Mounting Multiple Power Supplies FG N L FG N L 0mm FG N L 0mm no spacers between supplies required BLOCK DIAGRAM L N T2.5A Input Filter Power Stage E +V Output Filter -V DC Relay OTP ShutDown Protection OCP Limit OVP ShutDown OK LED Output Voltage Regulation Vadj. PACKAGING INFORMATION Parameter Packaging Dimension (LxWxH) Type cardboard box Packaging Quantity Value 116.0 x 97.0 x 54.0mm 1pcs Storage Temperature Range -30C to +85C Storage Humidity 10% - 90% RH The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 9/2019 PDR-6