8
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics (OPTION 060 ONLY)*
Description Symbol 8 Pin DIP SO-8 Unit
Installation classication per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 Vrms I – IV I – IV
for rated mains voltage ≤ 300 Vrms I – IV I – IV
for rated mains voltage ≤ 600 Vrms I – IV I – III
Climatic Classication 0/70/21 0/70/21
Pollution Degree (DIN VDE 0110/39) 2 2
Maximum Working Insulation Voltage VIORM 630 567 Vpeak
Input to Output Test Voltage, Method b*
VIORM × 1.875 = VPR, 100% Production Test with tm=1 sec, Partial discharge < 5 pC
VPR 1181 1063 Vpeak
Input to Output Test Voltage, Method a*
VIORM × 1.6 = VPR, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC
VPR 1008 907 Vpeak
Highest Allowable Overvoltage* (Transient Overvoltage tini = 60 sec) VIOTM 8000 6000 Vpeak
Safety-limiting values – maximum values allowed in the event of a failure
Case Temperature TS175 150 °C
Input Current IS, INPUT 230 150 mA
Output Power PS, OUTPUT 600 600 mW
Insulation Resistance at TS, VIO = 500 V RS≥ 109≥ 109Ω
* Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics (HCNW135/6 OPTION 060 ONLY)*
Description Symbol Characteristic Unit
Installation classication per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 Vrms I – IV
for rated mains voltage ≤ 300 Vrms I – IV
for rated mains voltage ≤ 600 Vrms I – IV
for rated mains voltage ≤ 1000 Vrms I – III
Climatic Classication 0/70/21
Pollution Degree (DIN VDE 0110/39) 2
Maximum Working Insulation Voltage VIORM 1414 Vpeak
Input to Output Test Voltage, Method b*
VIORM × 1.875 = VPR, 100% Production Test with tm=1 sec, Partial discharge < 5 pC
VPR 2651 Vpeak
Input to Output Test Voltage, Method a*
VIORM × 1.6 = VPR, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC
VPR 2262 Vpeak
Highest Allowable Overvoltage* (Transient Overvoltage tini = 60 sec) VIOTM 8000 Vpeak
Safety-limiting values – maximum values allowed in the event of a failure
Case Temperature TS150 °C
Input Current IS, INPUT 400 mA
Output Power PS, OUTPUT 700 mW
Insulation Resistance at TS, VIO = 500 V RS≥ 109Ω
* Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.