Du line Output Module for Rollerblind Motor Type G 8830 2149 230 (R) Fieldbus Installationbus * Up/down control of 1 rollerblind motor * Up/down interlocking for motor * AC power supply * Channel coding by GAP 1605 * Design for mounting in Euro box Ordering Key Product Description (R) Dupline output module for up/down control of one rollerblind motor. A built-in up/down interlocking function protects the motors. The motor requires two Dupline(R) channels, one for "UP" and one for "DOWN". For intelli- gent control of the rollerblind motors it is recommended to use the Master Generator G3800x01x which has this function built in. G 8830 2149 230 (R) Type: Dupline Housing Receiver No. of channels Output type Power supply Supply Specifications Type Selection Supply Ordering no. 2 channel 5 A/250 VAC 230 VAC G 8830 2149 230 Power supply AC types Rated operational voltage through wire L & N 230 Installations cat. III (IEC 60664) 230 VAC 15% (IEC 60038) Frequency Drop-out tolerance Power consumption Power dissipation Transient protection volt. 230 45 to 65 Hz 40 ms Typ. 3.3 VA 2W 4 kV Insulation voltage Supply - Dupline(R) Supply - Outputs Dupline(R) - Outputs 4 kVAC (rms) 4 kVAC (rms) 4 kVAC (rms) Output Specifications General Specifications Outputs Resistive loads Output OFF delay Upon loss of Dupline(R) carrier Power ON delay Power OFF delay Environment Pollution degree Operating temperature Storage temperature Humidity (non-condensing) Mechanical resistance Shock Vibration Dimensions (h x w x d) Material Weight Inductive loads Mechanical lifetime Electrical lifetime (at max load) Operating frequency Insulation voltage Outputs - Dupline(R) Response time AC 1 DC 1 or AC 15 DC 13 AC 1 1 SPST relay & 1 SPDT relay 5 A/250 VAC (1250 VA) 0.25 A/250 VDC (62 W) 2.5 A/230 VAC 5 A/24 VDC 30 x 106 operations 2.0 x 105 operations 7200 operations/h 4 kVAC (rms) 1 pulse train Specifications are subject to change without notice (14.01.05) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group 20 ms Typ. 2 s 1s 3 (IEC 60664) -20 to +50C (-4 to +122F) -50 to +85C (-58 to +185F) 20 to 80% 15 G (11 ms) 2 G (6 to 55 Hz) 50 x 50 x 30 ABS 100 g 1 Du line G 8830 2149 230 (R) Fieldbus Dimensions (mm) Mode of Operation As indicated on the wiring diagram, there are two relays in series to control the motor. O1 is used to switch the Motor ON/OFF and O2 is used to control the direction of the Motor UP/DOWN. In this way, it is made sure that the motors are not controlled UP and DOWN at the same time (interlocking). O1 and O2 may be coded individually by means of the code programmer GAP 1605. The de- Installationbus fault setting of the module is to switch all outputs off in case of loss of Dupline(R) carrier signal. The Master Generator G380X01X provides intelligent functions that makes it easy for the user to control the rollerblind motors individually or several at the same time (all UP or all DOWN). Programming Cable GAP-TPH-CAB Dot 50 30 50 Wiring Diagram Wiring Connections Bus: D+ D- Supply: Output: Black White Bus wires: Supply, Output: White = Black = Brown = Blue = Brown = Orange = Red = Dupline signal, D+ Dupline signal, DL N O1, Motor on/off O2, Motor up/down O2, Motor up/down 2 x 0,75 mm2 250V isolation, single core, 150 mm 5 x 1,5 mm2 250V isolation, single core, 150 mm Supply Brown Blue O2 O1 L N L Brown Orange N 1 Red M Accessories Programming cable to GAP 1650 2 GAP-TPH-CAB Specifications are subject to change without notice (14.01.05) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group