Mechanical Characteristics
Durability (mating cycles) ≥ 200
Insertion force 30 N typ.
Disengagement 20 N typ.
Material: outer conductor CuZn39Pb3
Material: inner conductor CuZn39Pb3
Material: spring contacts CuBe2
Material: spring basket
Material: insulators PTFE PTFE
Material: crimp ferrule Cu/CuZn39Pb3
Finish: Inner conductor Cu1Ni2Au0.8
Finish: Outer conductor NiP-Au / CuSnZn3 (Telealloy)
Finish: Other metal parts CuSnZn3 (Telealloy), stainless steel
Climatic Characteristics
Climatic category acc. to IEC 60068 - 1 40/85/21
Electrical Characteristics
Contact resistance inner conductor ≤ 3 mΩ
Contact resistance outer conductor ≤ 2.5 mΩ
Insulation resistance ≥ 5 GΩ
Voltage proof 1 kVeff/50 Hz
Impedance 50 Ω
Working voltage ≤ 500 Veff/50 Hz
Frequency range up to 6 GHz (18 GHz)
Note
QLS® is a registered trademark of the partners of the QLS® alliance.
2 / 2
© 2011 Telegärtner Karl Gärtner GmbH. Technische Änderungen vorbehalten. Technical changes reserved. www.telegaertner.com
Lerchenstr. 35, D-71144 Steinenbronn, Tel. +49 (0) 7157 125 100, Fax +49 (0) 7157 125 120, E-Mail: info@telegaertner.com