AP1117/AP1117I
Document number: DS31009 Rev. 22 - 2 3 of 13
www.diodes.com July 2012
© Diodes Incorporated
AP1117/AP1117I
Absolute Maximum Ratings (@TA = +25°C, unless otherwise specified.)
Symbol Parameter Rating Unit
VIN DC Supply Voltage -0.3 to +18 V
TMJ Maximum Junction Temperature +150 °C
PD
Power Dissipation
SOT89-3
SOT223
TO220-3
TO252
TO263
Internally limited by maximum junction
temperature of +150°C (Note 4)
mW
TST Storage Temperature -65 to +150 °C
Notes: 4. AP1117 contains an internal thermal limiting circuit that is designed to protect the regulator in the event that the maximum junction temperature
exceeded. When activated, typically at +150°C, the regulator output switches off and then back on as the die cools.
Recommended Operating Conditions (@TA = +25°C, unless otherwise specified.)
Symbol Parameter Min Max Unit
TOP Operating Junction Temperature Range AP1117 0 +125
°C
AP1117I -40 +125
Electrical Characteristics (@TA = +25°C, unless otherwise specified.)
Parameter Conditions Min Typ Max Unit
Reference Voltage AP1117-ADJ TA = +25°C, (VIN-OUT) = 1.5V
IO = 10mA 1.225 1.250 1.275 V
Output Voltage
AP1117-1.5 IOUT = 10mA, TA = +25°C,
3V VIN 12V 1.470 1.500 1.530 V
AP1117-1.8 IOUT = 10mA, TA = +25°C,
3.3V VIN 12V 1.764 1.800 1.836 V
AP1117-2.5 IOUT = 10mA, TA = +25°C,
4V VIN 12V 2.450 2.500 2.550 V
AP1117-3.3 IOUT = 10mA, TA = +25°C,
4.8V VIN 12V 3.235 3.300 3.365 V
AP1117-5.0 IOUT = 10mA, TA = +25°C,
6.5V VIN 12V 4.900 5.000 5.100 V
Line Regulation AP1117-XXX IO = 10mA,VOUT +1.5V < VIN < 12V,
TA = 25°C — — 0.2 %
Load Regulation
AP1117-ADJ VIN = 3.3V,VADJ = 0, 0mA < IO < 1A,
TA = +25°C (Notes 5, 6) — — 1 %
AP1117-1.5 VIN = 3V, 0mA < IO < 1A,
TA = +25°C (Notes 5, 6) — 12 15 mV
AP1117-1.8 VIN = 3.3V, 0mA < IO < 1A,
TA = +25°C (Notes 5, 6) — 15 18 mV
AP1117-2.5 VIN = 4V, 0mA < IO < 1A,
TA = +25°C (Notes 5, 6) — 20 25 mV
Notes: 5. See thermal regulation specifications for changes in output voltage due to heating effects. Line and load regulation are measured at a constant junction
temperature by low duty cycle pulse testing. Load regulation is measured at the output lead = 1/18” from the package.
6. Line and load regulation are guaranteed up to the maximum power dissipation of 15W. Power dissipation is determined by the difference between input
and output differential and the output current. Guaranteed maximum power dissipation will not be available over the full input/output range.