PowerPlus DC * Optically Isolated MOSFET output * Ratings from 10A to 100A @ 72 VDC * AC and DC control * Relays are easily paralleled for higher-current applications * LED Status Indicator * Optional IP20 Cover * UL Recognized, CE and RoHS Compliant * PWM to 1K Hz PRODUCT SELECTION Control Voltage 4-32 VDC 90-140 VAC 10A 20A 40A 60A 80A 100A DC100D10 DC100A10 DC100D20 DC100A20 DC100D40 DC100A40 DC100D60 DC100A60 DC100D80 DC100D100 AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1) Description Operating Voltage [Vdc] (2) Blocking Voltage Rated Load Current [Adc] (3) Minimum Load Current [mA] (4) Maximum Surge Current [Adc] (10ms) Maximum On-State Voltage Drop @ Rated Current [Vdc] Maximum Off-State Leakage Current @ Rated Voltage [mA] Thermal Resistance Junction to Case (Rjc) [C/W] Maximum On-State Resistance @ Rated Current [RDS-ON][mOhms] Maximum PWM [Hz] (5) 10A 20A 40A 60A 80A 100A 1-72 VDC 100 10 2.5 66 0.32 0.15 1.44 32 1K 1-72 VDC 100 20 2.5 91 0.34 0.15 0.85 17 1K 1-72 VDC 100 40 2.5 136 0.6 0.15 0.78 15 900 1-72 VDC 100 60 2.5 167 00.6 0.15 0.58 10 900 7-72 VDC 100 80 2.5 215 0.72 0.15 0.55 9 700 7-72 VDC 100 100 2.5 272 0.56 0.15 0.42 5.6 700 INPUT SPECIFICATIONS (1) Description Control Voltage Range Minimum Input Current @ min Control Voltage [mA] Maximum Input Current @ max Control Voltage [mA] Nominal Input Impedance Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] DCxxxDxx DCxxxAxx 4-32 VDC 11 12 Current Regulated 0.075 0.32 90-140 VAC 11 13 Current Regulated 10 10 GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 V DC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range (6) Ambient Storage Temperature Range Housing Material Weight (typical) (7) Encapsulation (8) Terminal Finish Recommended Terminal Screw Torque (6-32) [in lbs/Nm] Recommended Terminal Screw Torque (8-32) [in lbs/Nm] GENERAL NOTES 1) All parameters at 40C and per section unless otherwise specified. 2) Maximum voltage is 100VDC 3) Heat sinking required, see derating curves. 4) Low current loads and high ambient temperature can affect turn-on time. 5) @ a minimum of 8VDC control. See PWM Derating Information page 3. 6) Maximum Ambient Operating Temperature for the AC control relays is 65C. 7) Typical weight for the AC control relays is 2.99 oz/85g. 8) AC controlled relays contain thermal conductive epoxy. MECHANICAL SPECIFICATIONS Parameters 2500 Vrms 109 Ohm 10 pF -30 to 80C -40 to 125 C Valox 420 SEO Black, UL 94 V-0 2.65 oz (75g) Epoxy Free Electroless Nickel 10/1.1 20/2.2 WIRING DIAGRAM PWM DERATE INFORMATION AGENCY APPROVALS IEC 61000-4-2 Electrostatic Discharge Level 3, Criteria A IEC 61000-4-4 Electrically Fast Transients Level 3, Criteria A IEC 61000-4-5 Electrical Surges Level 3, Criteria A E116950 072312 THERMAL DERATE INFORMATION ANNEX - ENVIROMENTAL INFORMATION