JBX Push Pull Pull JBX Push Pull High reliability where quick, simple coupling mechanism is required Secure, quick confirmed mating Blind mate capability Tactile, Audible, Visual Mechanically keyed - prevents accidental engagement of wrong connector A versatile product Space Saving * Small footprint, allows access in tight applications * High density layouts 2 - 30 pins Economical Multiple cable collets / single part number www.souriau.com Rugged * Ergonomic design, fast and easy to use * Modular design * 5 shell sizes * Solder, crimp, PCB, R/A PCB contact terminations Metal shielding housing, high vibration and shock environments Push Pull Connectors Push Pull Connectors Part number system Contacts layouts JBX Basic series Shell type-Receptacle ER-EA-SR-PC-ED-EP-EZ-SA Shell type - Plug FD-FC-FF-FM-FN Shell size 00 - 0 - 1 - 2 - 3 Keying G-J-A-B Contact layout 02 ---------- 30 Contact type M : pin Contact termination FD 1 G 05 M C S D S M R Shell size 2 04 03 02 05 06 07 08 Male Insulator Wire Side Solder S S S S S S S C: crimp; S: solder; P*: straight PCB tails ; Q*: Right Angle PCB tails Crimp C C C C C C C Surface plating S : Outer shell brass alloy chrome over nickel plating PCB Straight Tails* XX XX P P P P P Q Q Q Q Q Obligatory Suffix Contact Size D : For all part numbers 1.3 1.3 1.3 0.9 Cable Backnut Option M : Connector with backnut for protective boot - Protective boot to order separately page 13 Key Identifier R : Red dot on shell for ED, ER, EZ, PC, SR, FC, FD, FF, FM & FN only F : socket N : Outer shell in brass alloy with black plating (consult Souriau USA) S : All contact diameters except .05 mm P : 0.5 mm contact dimensions only * For receptacles with female contacts only. Shell Types PCB Right Angle* Contact Diameter mm 1.3 1.3 1.3 10 12 16 S** Shell size 2 Male Insulator Wire Side 18 19 Technical characteristics ER : Front panel mount, fixed receptacle front flange FD : Straight plug EA : Front or rear panel mount with double nuts fixed receptacle Environmental Solder S S** * * * * Crimp C C C C C PCB Straight Tails* P P P P P PCB Right Angle* Q Q Q Contact Diameter mm 0.9 0.7 0.7 0.7 0.7 03 04 IP40 & IP 67/68 Temperature range: IP40 -40 - +125C Temperature range: IP67/68 -40 - +80C Shielding effectivity: 55dB up to 100MHg Mechanical EP : fixed receptacle, back panel mounting, fixed rear panel flange (appropriate with 90 contacts for PCB) FC : Right angle plug ED : Front mount protruding shell panel mount receptacle * * * * * * * * * Shell: Brass alloy Shell plating: Chrome over nickel Insulator: Peek Contact: Brass Contact plating: Gold Up to 8 key options 7 Color code options 5 Shell sizes >1,000 Mating cycles S** S** Shell size 3 07 08 10 14 18 22 30 S** Male Insulator Wire Side FN : Straight plug with lanyard Electrical SR : Front panel mount cable receptacle. fixed front flange PC : Inline cable receptacle FM : Right angle plug with lanyard EZ : PCB straight receptacle FF : Straight plug, no latch * Contact temination: Solder, Crimp PCB, R/A PCB * Contact rating: 0.5mm 2.0-2.5 Amp 0.7mm 5.0-7.0 Amp 0.9mm 7.0-10.0 Amp 1.3mm 11.0-15.0 Amp 1.6mm 15.0-17.0 Amp 2.0mm 25.0-30.0 Amp Solder S** S** S S S S S S** Crimp C C C C C C C C XX XX XX P P P P 2 2 1.6 1.3 1.3 0.9 PCB Straight Tails* P P 0.7 0.7 PCB Right Angle* Contact Diameter mm Please contact Souriau for additional technical information SA : Front or rear mount cable receptacle with double nuts, panel mount C 0.9 Push Pull Connectors Contacts layouts Push Pull Connectors KEYING * Voltage Test Procedure 04 in normal climatic conditions. The value is about 75% of the electrical breakdown voltage. The testing voltage level can be reached several times in connectors life, but never applied for a continuous duration. S - The working voltage corresponds to the maximum voltage the connector is able to withstand continuously during its life time, in real environmental conditions, even with high temperature. The value is around 1/3 of the testing voltage. Male Insulator Wire Side Solder J - The testing voltage corresponds to the maximum voltage the connector is able to withstand Shell size 00 Key Keying angle PCB Right Angle* Remark : If the current is applied on only one contact of the layout, then an increased current value can be achieved over a long duration. 0.5 Options * Protective boot 04 03 02 05 06 07 With each JBX connector, one protective boot can accept diverse cable diameters thus the end-user can manage various cable diameters without bothering with multiple part numbers. 08 Male Insulator Wire Side Solder S S S** S** Crimp C C C C PCB Straight Tails* P P P P PCB Right Angle* Q Q Q Q Contact Diameter mm 0.9 0.9 0.7 S** P S** 45 37.5 0 P 02 03 04 05 0.5 06 Solder S S S S S** Crimp C C C C PCB Straight Tails* P P P Q 1.3 PCB Right Angle* 1.3 Part number B* 30 60 0.5 07 08 S** S** C C C P P P P Q Q Q Q Q 0.9 0.9 0.7 0.7 0.7 **Inserts with fixed non removable contacts * For receptacles with female contacts. Note : Contact numbering mating faces receptacle view: counterclockwise from key at position 1 Contact numbering mating faces plug view: clockwise from key at position 1 Dimensions Shell size OA O Cable L min max JBX 00 MPN 00 1.5 15 1 3.5 JBX 0 MP* 0 2.2 20 1.5 5.5 JBX 1 MP* 1 2.6 25 2 7.5 JBX 2 MP* 2 4 30 3.5 9.7 JBX 3 MP* 3 5 35 4.9 12 * Color code - See chart below / In size 00, available only in black P Color code 0.7 A S** 0.5 Shell size 1 Contact Diameter mm sizes 2 - 3 Receptacle Shell size 0 Male Insulator Wire Side sizes 0 - 1 - This indicated maximum current rating corresponds to the maximum current that can be applied simultaneously on each line of the connector mated pair, continuously during its life time, in normal climatic conditions. PCB Straight Tails Contact Diameter mm G Plug * Maximum current rating Crimp Dual Key Way 10 S** 12 0.5 A blue Material : ELASTOLLAN (PUR) B white Working temperature : G grey - 40C ; + 80C J yellow - 40F ; + 176F M brown N black R red V green O orange Parts that require a protective boot need to be ordered with an M suffix. Protective boots are ordered separately. S** * Caps : an efficient protection against dust P Colors P 0.5 Receptacle Caps Part number Shell Size Plug Caps Part number Shell Size JBX BF00 00 JBX BR0 0 JBX BF0 0 JBX BR1 1 JBX BF1 1 JBX BR2 2 JBX BF2 2 JBX BR3 3 JBX BF3 3 Push Pull Connectors Push Pull Connectors Dimensions - Receptacles EA : Double nut ER : Front mount EP : Rear mount Dimensions - Plugs FM : Right angle with lanyard FC : Straight Plug with Lanyard Size 00 0 1 2 3 Size A 14 19 21 24 28 A B 6 8 10 10 12 B C 0.8 1.2 1.5 1.8 2.0 C 2.5 OD 8 10 14 18 22 OD 0 1 2 19 21 6.7 8.3 3.2 12 3 Size 24 28 8 9.5 3.8 4.5 16 20 24 ED : Front mount, protruding SA : Double nut panel mount receptacle 0 1 A 19 21 24 B 4.5 6 6.5 C 2.5 3.2 3.8 OD 12 2 16 20 SR : Front mount cable clamp Size 0 1 2 3 Size 0 1 2 3 Size 0 1 2 3 A 30.5 36.5 42.5 50.5 A 30.5 36.5 42.5 50.5 A 30.5 36.5 42.5 50.5 B 20.5 25.5 30.5 35.5 B 20.5 25.5 30.5 35.5 B 20.5 25.5 30.5 35.5 C 29.5 33.5 36.5 45 C 29.5 33.5 36.5 45 C 29.5 33.5 36.5 45 OD 10 12 15 18 OD 10 12 15 18 OD 10 12 15 18 0 1 2 3 A 38 43 50 59 A 19 B - - 6.5 - B 3 C 2.5 3.2 3.8 - C 1.2 OD 12 16 20 24 OD 10 Size 0 2 Size 0 1 2 3 21 24 A 38 43 50 59 4.5 6.3 B 8 10 10 12 1.5 1.8 C 1.2 1.5 1.8 2 14 18 OD 10 14 18 22 1 PC : In line receptacle EZ : PCB Size 00 0 1 2 FD : Straight FC : Right angle FN : Straight plug with lanyard Size FF : Straight, no latch 3 A 31 39 45 52 62 B 23 29 34 40 47 OC 8 1 13 16 19 Size 0 1 2 3 A 30.5 36.5 42.5 50.5 B 20.5 25.5 30.5 35.5 C 29.5 33.5 36.5 OD 10 12 15 Size 00 0 1 2 3 A 31 39 45 52 62 45 B 23 29 34 40 47 18 OC 7 10 12 15 18 Range of cable diameters With the plastic collet set supplied with the standard product, a wide range of cable diameters is allowed. Find below the maximum and the minimum for each size of shell (for information only because it can change with the cable characteristics). Size 0 1 10 19 4 12 21 4 7.62 1.1 7.62 1.1 Size 0 1 2 3 A 38 43 50 59 OA B C D OB 10 13 16 19.5 OE Size 00 0 1 2 3 O A min 1.1 1.5 2.0 3.5 4.9 O A Max 3.5 5.5 7.5 9.7 12.0 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Souriau: JBXBR0 JBXFD1G06MCSDSR JBXFD1G05MCSDSR JBXFD1G03MCSDSR JBXED0G03FSSDSR JBXFD1G04MCSDSR JBXFD1G07MCSDSR JBXEA1G05FCSDS JBX2MPR JBXFD1G04MSSDSR JBXFD1G07MSSDSR JBXFD1G06MSSDSR JBXFD1G05MSSDSR JBXFD1G03MSSDSR JBXEA3A10FCSDS JBXER2G19FSSDSR JBXER1G04FCSDSR JBXER1G06FCSDSR JBXER1G07FCSDSR JBXER1G03FCSDSR JBXER1G05FCSDSR JBXOUTDC07 JBXOUTDC09 JBXOUTDC13 JBXPC2G10FSSDSR JBXER0G04FCSDSR JBXER0G05FCSDSR JBXER0G02FCSDSR JBXER0G03FCSDSR JBXFD1G08MSSDSR JBXFD1G08MCSDSR JBXER1G08FSSDSR JBXFD2G07MCSDSR JBXFD2G10MCSDSR JBXFD2G05MCSDSR JBXFD2G12MCSDSR JBXFD0G05MSSDSR JBXFD0G02MSSDSR JBXFD0G04MSSDSR JBXFD0G03MSSDSR JBXFD2G19MSSDSR JBX1MPG JBX1MPN JBXER1G05FSSDSR JBXER1G04FSSDSR JBXER1G03FSSDSR JBXER1G07FSSDSR JBXER1G06FSSDSR JBX1OUTLP09 JBX1OUTLP07 JBX0OUTLP09 JBX2OUTLP09 JBX2OUTLP07 JBXER1G08FCSDSR JBX0OUTLP07 JBX1OUTLP13 JBX2OUTLP13 JBXFD2G10MSSDSR JBXFD2G16MSSDSR JBXFD2G05MSSDSR JBXFD2G12MSSDSR JBXFD2G07MSSDSR JBXER2G05FCSDSR JBXER2G10FCSDSR JBXER2G12FCSDSR JBXER2G07FCSDSR JBXER0G05FSSDSR JBXER0G04FSSDSR JBXER0G02FSSDSR JBXER0G03FSSDSR JBXER2G10FSSDSR JBXER2G05FSSDSR JBXER2G16FSSDSR JBXER2G12FSSDSR JBXER2G07FSSDSR JBXFD0G05MCSDSR JBXFD0G02MCSDSR JBXFD0G04MCSDSR JBXFD0G03MCSDSR JBXEA1G05FSSDS JBXFD2G06MSSDSMR JBXEA1G02FCSDS JBXEA1G02FPSDS JBXEA1G08FPSDS JBXEA2G10FCSDS JBXEA2G10FQSDS JBXEA2G10FSSDS JBXEA2J06FCSDS JBXED1G07FSSDSR JBXEP1G02FSSDS JBXER1G07FSSDS JBXER2G02FSSDSR JBXER2G06FSSDSR JBXEZ1G05FPSDSR JBXFC2G16MCSDSMR JBXFD0G02MSSDSMR JBXFD1G02MCSDSMR JBXFD2G02MSSDSMR JBXFD2G10FCSDSMR JBXFD2G10MCSDSMR