TM TM ChartScan/1400 & NetScan /1500 (R) Voltage and Temperature Recorders the smart approach to instrumentationTM ChartScan/1400TM * Serial-based paperless chart recorder * Connects to PC via RS-232/422 interface * Optional IEEE 488 interface available * Capable of stand-alone operation NetScanTM/1500 * Ethernet-based data logging and control instrument * Interface via 10BASE-T Ethernet or RS-232/422 * Can be controlled remotely via TCP/IP protocol Common Features Software (see p. 227) * ChartView TM or ChartViewNET TM Out-of-the-BoxTM scrolling strip-chart application for effortless setup, acquisition, & real-time display * DIAdem(R)-View for post-acquisition viewing of data files * ScanCalTM calibration software * LabVIEW (R) for Windows (R) virtual instrument (VI) example* * CIMScan (R) support for distributed applications * ScanServer TM support for popular SCADA/HMI applications NetScan/1500 provides measurement and control via Ethernet and the Internet Temperature & Voltage Scanning Instruments * Measure isolated temperature, DC volts, AC volts, & waveforms in one compact instrument * Convenient signal connectivity; recessed safety jack, BNC, subminiature plug, or screw-terminal connections * Expandable up to 128 channels * Measure 128 channels in less than one second * Single-channel burst mode for digitizing waveforms at rates up to 20 kHz * 32 alarm outputs & 8 digital inputs * Two programmable scan rates for: - pre- & post-trigger sampling - accelerated sampling on-event detection * 128 Kreadings of memory, expandable up to 4 Mreadings * Built-in real-time clock: - synchronizes acquisition to time of day - provides time & date stamping for trend monitoring * RS-232 interface standard The ChartScan/1400 and NetScan/1500 are compact voltage and temperature recorders that can be used as paperless chart recorders or as data logging and control instruments. Their convenient BNC, safety jack, subminiature plug, and screw-terminal connectors make signal connection easier than other data recorders or loggers. Both systems offer high speed, high channel counts, voltage isolation, and user-selectable signal conditioning. ChartScan/1400 The ChartScan/1400 is a next-generation recorder that combines the ease-ofuse common in paper-based strip-chart recorders with the advanced features of PC-based data acquisition systems. The ChartScan offers distinct advantages over typical chart recorders. For example, it is not prone to mechanical failure like conventional paper-based recorders with chart drives, paper feeds, moving pens, and knobs. The ChartScan/1400 portable recorder is ideal for making isolated temperature and voltage measurements (notebook PC not included) * Contact factory for NetScan Ethernet support in LabVIEW Q U I C K tel: 440-439-4091 fax: 440-439-4093 205 F I N D sales@iotech.com www.iotech.com TM TM ChartScan/1400 & NetScan /1500 (R) General Information the smart approach to instrumentationTM NetScan/1500's back panel provides an Ethernet and additional RS-232 port Unlike other hybrid recorders--which are often handicapped by difficult menu systems, low-visibility LCD displays, and inconvenient multi-purpose keypads-- the ChartScan/1400 features Windows (R)based ChartView software for easy setup, acquisition, and real-time display, right Out-of-the-BoxTM. ChartView Out-of-the-BoxTM data logging software provides effortless real-time scrolling and data capture to disk Temperature & Voltage Scanning Instruments NetScan/1500 Now take measurements and output control signals wherever there is an Ethernet connection. The new NetScan/1500 offers 16 to 128 isolated channels of voltage and direct thermocouple measurements. In addition, 32 digital outputs can be programmed to automatically operate as alarm outputs, or can be individually controlled via the network. Eight digital inputs allow the network to read the status of digital signals. Since the NetScan/1500 system uses TCP/IP protocol, users can also communicate with distant NetScan devices via an Internet-accessible Ethernet address. ChartViewTM Software The ChartScan/1400 includes ChartView, one of IOtech's Out-of-the-BoxTM, Windowsbased setup and acquisition applications (see p. 228). ChartView provides a graphical spreadsheet-style user interface that lets you easily configure your hardware, acquisition, and display parameters. ChartView features a no-programming approach that enables data collection and display within minutes of taking the ChartScan/1400 Out-of-the-BoxTM. Optional ChartView PlusTM adds expanded display and recording capabilities. ChartViewNETTM Software The NetScan/1500 includes ChartViewNET software (see p. 228), the Ethernet version of IOtech's popular ChartView software. The easy-to-use graphical application allows the NetScan to be accessed from any PC on the network. Accessing one NetScan at a time, ChartViewNET's chart recorderlike interface provides real-time, smoothscrolling waveforms plus logging to disk. It also offers a variety of real-time indicators, such as bar graphs, dials, and digital display. Optional ChartViewNET PlusTM adds expanded display and recording capabilities to ChartViewNET software. For applications that require concurrent access to multiple NetScan devices, use CIMScan or ScanServer software. Optional CIMScan(R) software (see p. 235) is a low-cost SCADA/HMI application for distributed acquisition and control applications, where a single CIMScan screen can Q U I C K tel: 440-439-4091 fax: 440-439-4093 206 display data from, and control outputs of, multiple NetScan devices distributed throughout a network. Custom applications that access thousands of channels from distributed NetScans can easily be created without programming. Optional ScanServerTM software (see p. 240) permits access to any number of NetScans from all popular SCADA/HMI applications, such as those from Wonderware(R) and Intellution(R). ScanServer supports all OPC/ DDE-compliant environments, including Microsoft(R) Excel. Common Architecture The ChartScan/1400 and NetScan/1500 share an advanced architecture that offers an unrivaled low-cost per channel. Both instruments scan at 147 readings/s and can stream data direct-to-disk (your PC's hard drive) in real time. For stand-alone operation, the systems come standard with 128 Kreadings (256 Kbytes) deep memory that is expandable to 4 Mreadings (8 Mbytes). F I N D sales@iotech.com www.iotech.com TM TM ChartScan/1400 & NetScan /1500 (R) General Information the smart approach to instrumentationTM Feature The ChartScan/1400 and NetScan/1500 are ideal for temperature and voltage measurements that require channel-to-channel isolation. The systems provide 500V isolation for high-voltage applications using the CSN14/HV/S module and 200V isolation when the thermocouple and other voltage modules are used. The systems achieve this high isolation by using individual relays on each channel, yet still maintain a very fast 147 channels/s scan rate. Expansion Options The ChartScan/1400 and NetScan/1500 chassis can accommodate up to four plug-in option modules for a total of 64 channels. For larger systems, the CSN/Exp expansion chassis connects directly to the main unit to allow four additional plug-in modules, expanding the system from 64 to 128 channel capacity. Power is derived directly from the main unit so no additional power supplies or cables are required. Faster Scanning The ChartScan/1400 and NetScan/1500 offer faster scanning than a typical stripchart recorder, and exceed the typical two Hz rate found on most strip-chart, multi-point, or hybrid recorders. The units provide an array of scanning capabilities to meet your application requirements. Because data-logging and chart recording applications frequently require logging at fixed time intervals, the systems use the standard hours-minutesseconds (hh:mm:ss.s) format to specify the time interval between channel scans. Users can configure the unit to begin and end data logging on a specified event such as a TTL signal, temperature level, IEEE GET, alarm condition, absolute time of day, or upon completion of a specified number of readings. Measurement Parameters A/D resolution Accuracy (w/J thermocouple) Thermocouples supported Voltage input Channel-to-channel isolation Channel-to-system isolation Scanning Parameters Switching technology Max scan rate Max single-channel scan rate Min channel configuration Max channel configuration Data Handling Built-in memory Max memory with expansion IEEE 488 interface RS-232 interface Ethernet Time & date stamping Triggering Digital trigger input Analog trigger input Trigger on time of day Pre-trigger scan rate Post-trigger scan rate Digital Inputs Programmable Alarm Outputs Software ChartView ChartView Plus ChartViewNET ChartViewNET Plus LabVIEW CIMScan ScanServer Hardware Options 16-ch isolated TC/voltage scanning module 16-ch isolated low voltage scanning module 16-ch isolated high voltage scanning module 4-slot expansion chassis 16-ch digital output relay card fax: 440-439-4093 NetScan/1500 16 bit w/oversampling 0.5C J,K,T,E,R,S,B,N 100 mV to 250V up to 500V 500V 16 bit w/oversampling 0.5C J,K,T,E,R,S,B,N 100 mV to 250V up to 500V 500V mechanical relays 147 channels/s 20 kHz 16 channels 128 channels mechanical relays 147 channels/s 20 kHz 16 channels 128 channels 128 Kreadings 4 Mreadings optional 128 Kreadings 4 Mreadings optional optional programmable programmable 8 32 programmable programmable 8 32 included optional -- -- included optional optional included optional included optional -- optional optional CSN/Exp Expansion Chassis ChartScan/1400 or NetScan/1500 Programmable Scan Rates. The ChartScan/1400 and NetScan/1500 offer programmable scan rates for applications requiring acceleration of the measurement rate on a specified event, such as an alarm condition. For example, you Q U I C K tel: 440-439-4091 ChartScan/1400 207 can program the instrument to scan once per minute and then, upon the occurrence of a specified alarm condition, switch to scanning once per second. Upon cessation of the alarm condition, the unit resumes scanning at the rate of once per minute. F I N D sales@iotech.com www.iotech.com Temperature & Voltage Scanning Instruments Isolated Inputs TM TM ChartScan/1400 & NetScan /1500 General Information (R) the smart approach to instrumentationTM Scanning Techniques Typical Expansion Module Block Diagram The ChartScan/1400 and NetScan/1500 offer three measuring modes for application flexibility. These include a line-cycle integration mode, a high-speed multichannel scanning mode, and a single-channel burst mode. A discussion of the particular attributes of each measuring mode follows. Open T/C detection sources Cold-junction compensation sensors Line-Cycle Integration. The ability to sample and average 32 measurements per line cycle over multiple line cycles, makes the systems useful for high-accuracy applications and thermocouple measurements in applications subject to high AC noise environments. When engaged in line-cycle averaging, the units provide AC or DC voltage, or linearized and compensated thermocouple-based temperature readings at up to 44 channels/s. The AC voltage measurement capability is ideal for power-line monitoring applications. For each measurement, the unit calculates the equivalent true RMS voltage based on 32 samples it acquires during each AC line cycle. Auto zero Ch 1 Analog Outputs IA PGA to A/D Isolation relays Gain/sequence decoding Processor controller Relay coil decoder/driver Ch 16 Line Cycle Integration Line DC Volts & AC Maximum Cycles Thermocouples Volts Channel per Reading 50 Hz 60 Hz 50 Hz 60 Hz Number 128 1 38.5* 44* 38.5* 44* 22* 128 19.2* -- -- 2 9.6* 128 -- -- 11* 4 8 4.8* 5.5* 122 -- -- Accuracy The ChartScan/1400 and NetScan/1500 have a number of features and capabilities that enable them to deliver the high accuracy demanded by many research applications. Temperature & Voltage Scanning Instruments * channels/s High-Speed Multichannel Scanning. When line-cycle averaging is disabled, the systems can average 1, 2, 4, 8, or 16 samples per channel. When the units are configured to take 1 sample per channel, they can scan 147 channels/s or all 128 channels in under one second. This is important when trying to timecorrelate a large number of channels. By contrast, data loggers and other temperature measuring instruments typically acquire readings at only 5 to 20 channels/s. Single-Channel Burst Mode. In single-channel burst mode, the systems can sample at up to 20 kHz on a single channel and store the data in memory, which can be expanded up to 4 Mreadings. When performing post-acquisition waveform analysis such as Fast Fourier Transforms (FFTs), the units can return each data point in a waveform to your program. Alternatively, the units can provide a true RMS value of the sampled voltage. High Resolution. The systems are equipped with a high-speed 16-bit A/D converter. This enables the systems to offer up to 0.1C and 3.05 V resolution with the CSN14/TC/P thermocouple/volt scanning module. Noise Filtering. The systems reduce noise by sampling and averaging 32 measurements per line cycle. The systems also offer the flexibility to average across multiples of 1, 2, 4, or 8 line cycles. High-Accuracy Cold Junction Compensation. The systems' CSN14/TC/P thermocouple/volt scanning module features multiple, strategically-located temperature sensors that provide high-accuracy, cold-junction compensation across all inputs. Accurate Linearization. The systems enable quick and accurate linearization by providing built-in lookup tables for popular thermocouple types, including J, K, T, E, R, S, B, and N. Q U I C K tel: 440-439-4091 fax: 440-439-4093 208 F I N D sales@iotech.com www.iotech.com TM TM ChartScan/1400 & NetScan /1500 (R) General Information the smart approach to instrumentationTM Alarms Detecting an alarm condition is a common requirement in logging applications and the ChartScan/1400 and NetScan/1500 offer a number of modes to facilitate alarm detection. With 32 digital TTL alarm outputs available on the 50-pin rear panel connector or 16 outputs via the high-current capacity CSN/Relay option*, multiple conditions can be set and monitored. Unlike some instruments which allow only one channel to be assigned to a single alarm output, the ChartScan/1400 or NetScan/1500 allow one or more channels to be logically "OR-ed" and connected to an alarm output. In this way, all 128 channels can participate in the alarm process. Channel settings for alarm limit and hysteresis are individually set with the alarm output remaining high for as long as the alarm condition is valid. CSN/Relay Card Block Diagram 2-coil latch relay Alarm 1 Pulse circuit Set Reset Buffer Disconnectable terminal block 2-coil latch relay Alarm 8 Pulse circuit Set Reset Buffer Edge connector 2-coil latch relay Alarm 9 Pulse circuit Set Reset Buffer Disconnectable terminal block 2-coil latch relay Alarm 16 Pulse circuit Set Reset CSN/Relay card supports 16 high-current alarm outputs The units' ability to automatically update alarm outputs in real time affords you greater control of your applications and reduces your programming burden by eliminating the need for constant per-channel monitoring by the controlling computer. memory, enabling later retrieval of this information for use in plotting and analyzing measurements. The instrument also time and date stamps each channel's high and low excursions, providing a precise time record of a channel's minimum and maximum values. Memory In addition, the units can update alarmed output channels in real time, at their programmed scan rates, and can alert the host computer of active alarm conditions via an IEEE 488 service request (SRQ). For high-speed and long-term data logging, the systems are equipped with 128 Kreadings of data storage, which can be field expanded to 4 Mreadings. Since each application requires different measurements, the units make each channel's high, low, and last readings available throughout acquisition. Real-Time Clock ChartScan Communication The ChartScan/1400 and NetScan/1500 feature a real-time clock that allows you to synchronize acquisition to a specific time of day. During acquisition, the system stores the time and date of every data scan in Connecting your computer to the ChartScan/1400 is simple via the standard RS-232/422 interface. In addition, an optional IEEE 488 interface can be added via a simple plug-in module. ChartScan supports any Hayes-compatible modem. IEEE 488. The CSN/COM/488 option fully supports the IEEE 488.2 standard and can transfer data up to 300 Kbytes/s. This interface plugs directly into the communications port on the back of the unit and lets you set up, control, and log data from the instrument directly to the computer. IEEE 488 is most commonly used in multiinstrument applications where one computer is used with many instruments. NetScan Communication Connecting a Local Area Network (LAN) or Wide Area Network (WAN) to the NetScan/1500 is simple via the standard 10BASE-T Ethernet interface. This allows any PC on the network to access the NetScan. In addition, a second port is available for RS-232/422 communication with a local PC. A serial-based device may be attached to this port and accessed through the NetScan/1500**. Internet. If the LAN or WAN has a gateway to the Internet, then a network PC can communicate with remotely located NetScans via TCP/IP protocol. * CSN/Relay Card occupies one slot in the mainframe reducing total channels to 48, expandable to 112 ** This feature is not supported by ChartViewNET Q U I C K tel: 440-439-4091 fax: 440-439-4093 209 F I N D sales@iotech.com www.iotech.com Temperature & Voltage Scanning Instruments Buffer TM TM ChartScan/1400 & NetScan /1500 (R) Scanning Modules the smart approach to instrumentationTM Temperature & Voltage Modules Input modules are ideal for making isolated temperature and voltage measurements. Each features 16 isolated inputs and plugs directly in the ChartScan/1400 or NetScan/1500. Depending upon the module and signal input, each card uses either standard BNC, safety jack, removable screw-terminal block or thermocouple plugs for quick and easy input connections. The modules slide into a shielded metal enclosure within the ChartScan/1400 or NetScan/1500, keeping noise to a minimum and maintaining a stable internal temperature for accurate Cold Junction Compensation (CJC) reading. All scanning modules feature isolated, differential input capabilities that can make accurate measurements in high common-mode voltage applications. Each relay-isolated channel can be scanned at up to 147 channels/s. In that time, all channels are logged to memory, high/low/last registers are updated, alarms are reported, and thermocouple inputs are cold junction compensated and linearized. Modules can be mixed to match your application. ChartScan/1400 & NetScan/1500 Modules Model CSN14/TC/P Temperature & Voltage Scanning Instruments CSN14/LV/B CSN14/LV/T CSN14/LV/S CSN14/HV/S Type Input Connector Type T/C and Voltage Low Voltage Low Voltage Low Voltage High Voltage J, K, T, E, R, S, B, N, 10V, 5V, 1V, and 100 mV 10V, 5V, 1V and 100 mV 10V, 5V, 1V and 100 mV 10V, 5V, 1V and 100 mV 250V, 25V, and 2.5V Subminiature Plug BNC Screw Terminal Safety Jack Safety Jack Temperature Scanning Voltage Scanning The ChartScan/1400 and NetScan/1500 scan the most popular thermocouple types and voltages up to 10V using the CSN14/TC/P 16-channel thermocouple and voltage module. Convenient subminiature plugs are used for signal input. To meet your application needs, the low-voltage scanning modules support the most popular connectors used today. The low-voltage options (up to 10V) are available with either BNC, removable screw-terminal, or safety-jack inputs. The high-voltage (up to 250V) scanning module features safety-jack inputs only. CSN14/TC/P 16-channel thermocouple and voltage scanning module CSN14/LV/B 16-channel low-voltage scanning module with BNC input CSN14/LV/S 16-channel low-voltage scanning module with safety-jack input CSN14/LV/T 16-channel low-voltage scanning module with removable screwterminal input CSN14/HV/S 16-channel high-voltage scanning module with safety-jack input Q U I C K tel: 440-439-4091 fax: 440-439-4093 210 F I N D sales@iotech.com www.iotech.com TM TM ChartScan/1400 & NetScan /1500 (R) Specifications the smart approach to instrumentationTM Specifications Ethernet Interface (NetScan) Number of Slots: 4 (expandable to 8 with CSN/Exp option discussed below) Number of Channels: Up to 64 differential thermocouple or voltage inputs; accepts CSN14/TC/P, CSN14/LV/T, CSN14/LV/B, CSN14/LV/S, and CSN14/HV/S scanning modules (expands to 128 channels; see CSN/Exp below) Channel Attributes: High and low set points; hysteresis value for high & low set points A/D Resolution: 16 bits Scan Sequence: Any combination of temperature and voltage channels may be scanned in ascending numerical order Scan Interval: Relative time between channel scans; minimum = 6.8 ms; maximum = 99:59:59.9 (hh:mm:ss.s) Calibration Scanning Rates Protocol: TCP/IP Media: 10BASE-T Interface: RJ-45 shielded connector Indicators: Enabled, link, activity Calibration Cycle: One year Calibration Constants: Chassis constants stored in nonvolatile memory; card constants stored in EEPROM; each unit includes ScanCal, example software for automating its calibration procedure; calibration is enabled via software password and by hardware enable switch General Programmable Triggering Trigger Criteria: Temperature or voltage above or below a level, absolute time of day, alarm condition (on or off), IEEE GET, IEEE TALK, external TTL trigger (level high or level low), specified number of readings Level Trigger: Programmable value for any one channel* TTL Trigger: Programmable for high or low level Pre-Trigger Count: Programmable (< memory size - 1) Post-Trigger Count: Programmable Indicators: LEDs for alarm, scanning, error, send, receive, power, and trigger status Power: 105 to 125 or 210 to 250 VAC, 50/60 Hz; 20 VA max Warm-Up: One hour to rated accuracy Environment: 0 to 50C; 0 to 95% RH, non-condensing to 35C; linearly derate 3% RH/C from 35C to 50C Digital I/O and Alarms: Female DB50 (32 alarms, 8 digital inputs, 10 ground pins) Trigger Input: BNC TTL Output: BNC Dimensions: 330 mm W x 241 mm D x 152 mm H (13" x 9.5" x 6") Weight: 4.3 kg (9.6 lbs) Optional Communication Interface - ChartScan/1400 only Alarms & Digital I/O CSN/COM/488--IEEE 488 Interface Number of Digital Alarm Outputs: 32 TTL-level compatible and 16 high-current outputs using the optional CSN/Relay module Number of Digital Inputs: 8 bits, TTL compatible Connector: 50-pin D-connector; mating connector supplied Alarm Conditions: Can be detected by SRQ or software query CSN/Exp Expansion Chassis Data Storage & Format Storage: 128 Kreadings standard; optional 500 Kreadings, 2 Mreadings, and 4 Mreadings user-installable Data Formats: ASCII or binary; binary format returns a 16-bit compensated and linearized temperature value (0.1C/bit); user programmable for hi byte/lo byte or lo byte/hi byte Note: High-speed DMA transfers use binary format only Statistical Parameters: High, low, and last available per channel Time Stamp: Available for each scan group and for each channel's high, low, and last parameters* Time Format 1. Absolute date and time (mm/dd/yy hh:mm:ss.sss) 2. Relative time (hh:mm:ss.sss,DDDDDDD) Implementation: SH1, AH1, T6, TE4, L4, LE4, SR1, PP0, RL0, DC1, DT1, C0, & E1 Programmable Parameters: Alarm set points, thermocouple types, temperature units, IEEE 488 connector with metric studs Number of Slots: 4 Number of Channels: Up to 64 in any combination of CSN14 modules for the ChartScan/1400 Power: Powered from the ChartScan/1400, no external connection needed Environment: 0 to 50C; 0 to 95% RH, non-condensing to 35C; linearly derate 3% RHC from 35 to 50C Dimensions: 330 mm W x 241 mm D x 152 mm H (13" x 9.5" x 6") Weight: 1.82 kg (4 lbs) Alarm Monitoring Module CSN/Relay Module** Relay Alarm Outputs: 16 Contact Rating: 8 amps @ 250V Maximum Current: 10 amps per bank of 8 RS-232/422 Interface (ChartScan & NetScan) Baud Rates: 300, 2400, 4800, 9600, 19200 Data Bits: 8 Stop Bits: 1 Parity: Even, odd, none Handshaking: RTS/CTS, XON/OFF Connector: Male DB-9 * Not available when using single-channel burst mode ** Occupies one slot in the mainframe; one card per system Q U I C K tel: 440-439-4091 fax: 440-439-4093 211 F I N D sales@iotech.com www.iotech.com Temperature & Voltage Scanning Instruments Multichannel: Rates up to 147 channels/s (50/60 Hz) 32 point averaging: 44 channels/s (60 Hz); 38.5 channels/s (50 Hz), Single Channel Burst: 20 Ksamples/s, single-channel burst mode TM TM ChartScan/1400 & NetScan /1500 (R) Specifications the smart approach to instrumentationTM Scanning Module Specifications CSN14/LV/T 16-Channel Isolated Low-Voltage Scanning Module CSN14/TC/P 16-Channel Thermocouple and Voltage Scanning Module Number of Inputs: 16 differential; programmable by channel for specific input range Input Connectors: Removable screw terminal block Range and Resolution Resolution Range6 100 mV 3.05 V/bit 1V 30.5 V/bit 5V 153 V/bit 10V 306 V/bit Accuracy: 0.02% of range7,10 Line Cycle Noise Rejection: Software enabled for the averaging of 1 through 255 samples over multiple AC line cycles Maximum Common Mode Voltage1,2: 200 VDC or AC peak Input Impedance: 1M Ohm Input Bias Current: 20 nA max Maximum Normal Mode Voltage: 10 VDC or AC peak Common Mode Rejection: 100 dB typ Maximum Allowable Input: 25 Vrms Channel-to-Power Ground Isolation: 200V peak Channel-to-Channel Isolation: 200V peak Temperature Coefficient: < (0.1 x rated accuracy)%/C Number of Channels: 16 differential; programmable by channel for specific thermocouple type or voltage input Inputs: J, K, T, E, R, S, B, N, 10V, 5V, 1V and 100 mV Input Connectors: Subminiature plug Maximum Allowable Input: 25V rms Input Impedance: 1M Ohm Input Bias Current: 20 nA max Maximum Common Mode Voltage1, 2: 200 VDC or AC peak Maximum Normal Mode Voltage: 10 VDC or AC peak Channel-to-Power Ground Isolation: 200 VDC or AC peak Channel-to-Channel Isolation: 200 VDC or AC peak Temperature Coefficient: <(0.1 x rated accuracy)%/C Line Cycle Noise Rejection: Software enabled for the averaging of 1 through 255 samples over multiple AC line cycles Temperature & Voltage Scanning Instruments Temperature Specifications Temperature Range and Accuracy3,4 Type Range Accuracy5,10 J -100 to +760C 0.5C -200 to -100C 0.8C K -100 to +1372C 0.6C -200 to -100C 0.8C T -100 to +400C 0.5C -200 to -100C 0.8C E -100 to +1000C 0.7C -200 to -100C 0.9C R 0.0 to +1780C 2.0C S 0.0 to +1780C 2.0C B +350 to +1820C 2.0C N -100 to +1300C 0.6C -200 to -100C 0.9C Units: C, F, K, R, mV & Volts Fault Detection: Open thermocouple can be detected by software query Cold Junction Sensors: One for every 4 input channels Linearization: Performed by lookup table CSN14/LV/B 16-Channel Isolated Low-Voltage Scanning Module Same specification as the CSN14/LV/T except with a BNC input connector CSN14/LV/S 16-Channel Isolated Low-Voltage Scanning Module Same specification as the CSN14/LV/T except with a safety jack input CSN14/HV/S 16-Channel Isolated High-Voltage Scanning Module Number of Inputs: 16 differential; programmable by channel for any input range Input Connectors: Safety jack Range and Resolution Range6 Resolution 2.5V 78.14 V/bit 25V 781.4 V/bit 250V 7.814 mV/bit Accuracy: 0.02% of range7,10 Line Cycle Noise Rejection: Software enabled for the averaging of 1 through 255 samples over multiple AC line cycles Maximum Allowable Input: 500 VDC or AC peak Input Impedance: 10M Ohm Input Bias Current: 20 pA max Maximum Common Mode Voltage1,8,9: 500 VDC or AC peak Maximum Normal Mode Voltage: 500 VDC or AC peak Common Mode Rejection: 100 dB typ Channel-to-Power Ground Isolation: 500 VDC or AC peak Channel-to-Channel Isolation: 500 VDC or AC peak9 Temperature Coefficient: <0.01%/C AC/DC Voltage Specifications Range and Resolution Range6 Resolution 100 mV 3.05 V/bit 1V 30.5 V/bit 5V 153 V/bit 10V 306 V/bit Accuracy: 0.02% of range7,10 1. 2. 3. 4. 5. 6. 7. Specified for coupling impedance > 30M Ohm and common mode frequency < 60 Hz 300 VDC or AC peak before equipment damage occurs 18 to 28C, 1 year; includes cold junction compensation Typical; excludes thermocouple errors Add 5C for common mode voltages greater than 25 VAC Maximum peak-to-peak signal for AC volts For AC voltages where the frequency of the input signal is an integer multiple of the AC line cycle 1% 8. 700 VDC or AC peak before equipment damage occurs 9. 325 VDC or AC peak if used in the same system with the CSN14/TC/P scanning module 10. With line cycle integration enabled Q U I C K tel: 440-439-4091 fax: 440-439-4093 212 F I N D sales@iotech.com www.iotech.com TM TM ChartScan/1400 & NetScan /1500 (R) Ordering Information the smart approach to instrumentationTM Cables Description Part No. High-speed isolated temperature and voltage measurement instrument, includes RS-232 interface; ChartViewTM & DIAdem(R)-View software; and DB50 digital I/O port mating connector ChartScan/1400* High-speed isolated temperature and voltage measurement instrument, includes Ethernet interface; ChartViewNETTM & DIAdem-View software; and DB50 digital I/O port mating connector NetScan/1500* 4-slot expansion chassis CSN/Exp 16-channel thermocouple/volt scanning module CSN14/TC/P 16-channel low-voltage scanning with removable screw-terminal input module CSN14/LV/T 16-channel low-voltage scanning with BNC input module CSN14/LV/B 16-channel low-voltage scanning with safety jack input module CSN14/LV/S 16-channel high-voltage scanning with safety jack input module CSN14/HV/S 16-channel alarm/relay module CSN/Relay Description RS-232 serial port cable (9- and 25-pin sub D) to (9-pin sub D) for the ChartScan/1400, 6 ft. Shielded IEEE 488 cable, 6 ft. Cables, probe and alligator clips for safety jack input ChartView PlusTM ChartViewNET PlusTM LabVIEW(R) VI example for the ChartScan/1400** CIMScan(R), SCADA/HMI application ScanServerTM, server for SCADA/HMI applications CN-144-JM CN-144-KM CN-144-TM CN-144-EM CN-144-RM CN-144-SM CN-144-BM CN-144-NM CN-144-UM CSN/MEM1 CSN/MEM4 CSN/MEM8 ChartView Plus ChartViewNET Plus LBV/DAI CIMScan ScanServer Note: The full range of software support is discussed on p. 227. Related Products Hardware Net232 Thermocouples p. 225 p. 301 Software DIAdem ChartView ChartViewNET CIMScan ScanServer p. p. p. p. p. 198 228 228 235 240 Note: Buy your thermocouples direct from IOtech. See p. 301 for an overview of the various thermocouple types offered. Memory Options 1 Mbyte memory option (500 Kreading) 4 Mbyte memory option (2 Mreading) 8 Mbyte memory option (4 Mreading) CA-47 CA-7-3 CA-161 Software Male Connectors for Subminiature T/C Jacks Type J for CSN14/TC/P Type K for CSN14/TC/P Type T for CSN14/TC/P Type E for CSN14/TC/P Type R for CSN14/TC/P Type S for CSN14/TC/P Type B for CSN14/TC/P Type N for CSN14/TC/P Copper to copper male connector Part No. Q U I C K F I N D For up-to-date information on products, and to order online, visit the IOtech Web site and enter the corresponding page number in the QUICK FIND field. Interface Options IEEE 488 interface option SHOP ON LINE CSN/COM/488 Rack Mount Kits Mainframe rack-mount kit Expansion chassis rack-mount kit CSN/Rack1 CSN/Rack2 * Scanning modules must be ordered separately ** IEEE-488 example only; contact factory for serial support Q U I C K tel: 440-439-4091 fax: 440-439-4093 213 F I N D sales@iotech.com www.iotech.com Temperature & Voltage Scanning Instruments Ordering Information