Housing Nbr of signal Contact Contact termination Contact termination Contact termination
type contacts arrang.
shost post W.W. one wrap rear plug up
24+8 24 8609.324.HP.94.7x5.000.E3 8609.324.HP.91.7x5.000.E3 8609.324.HP.96.7x5.000.A
24+8 16 8609.416.HP.94.7x5.000.E3 8609.416.HP.91.7x5.000.E3 8609.416.HP.96.7x5.000.A
42+6 42 8609.342.FP.94.7x5.000.E3 8609.342.FP.91.7x5.000.E3 8609.342.FP.96.7x5.000.A
42+6 28 8609.428.FP.94.7x5.000.E3 8609.428.FP.91.7x5.000.E3 8609.428.FP.96.7x5.000.A
60+4 60 8609.360.DP.94.7x5.000.E3 8609.360.DP.91.7x5.000.E3 8609.360.DP.96.7x5.000.A
60+4 40 8609.440.DP.94.7x5.000.E3 8609.440.DP.91.7x5.000.E3 8609.440.DP.96.7x5.000.A
78+2 78 8609.378.BP.94.7x5.000.E3 8609.378.BP.91.7x5.000.E3 8609.378.BP.96.7x5.000.A
78+2 52 8609.452.BP.94.7x5.000.E3 8609.452.BP.91.7x5.000.E3 8609.452.BP.96.7x5.000.A
Performance class / plating:
•DIN 41612 class III: replace x by 4 in part number.
• DIN 41612 class II: replace x by 5 in part number.
• DIN 41612 class I: replace x by 6 in part number.
Contact plating: selective gold over nickel on contact area, tin-lead on termination.
Technical characteristics of the power contacts:
Current rating: 40 A at 20°C
Contact resistance: ≤1m Ωunder 10 A
Performance class: DIN41612 class 1,500 operations
Insertion / withdrawal force: ≤10N
Press in force: ≤120N
Push out force: ≥40N
Application tooling: see pages 99-101.
Plated thru hole requirements for signal contacts: Plated thru hole requirements for power contacts:
drilled hole: 1,15±0,025 (.0453±.0010) drilled hole: 3,20±0,03 (.125±.0010)
finished hole: 0,94 (.037) min. finished hole: 3,02 (.118) min.
1,09 (.043) Max. 3,20 (.125) Max.
Cu plating: 0,025 (.00098) min. Cu plating: 0,025 (.00098) min.
0,050 (.00196) Max. 0,050 (.00196) Max.
SnPb: 0,008 (.0003) min. SnPb: 0,008 (.0003) min.
0,015 (.0006) Max. 0,015 (.0006) Max.
Catalogue numbers - standard items