70 Low Signal Relay G6A
■Characteristics
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
2. Values in parentheses are typical values unless otherwise stated.
3.
The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those for checking the dielectric strength
(except between the set and reset coil).
4. The above values are initial values.
■Approvals
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C
Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics
individually defined in this catalog.
2. In the general interest of product improvement, specifications are subject to change.
Type Non-latching Latching
Contact resistance (See note 1) 50 mΩ max.
Operate (set) time
(See note 2)
DPDT 5 ms max. (mean value approx. 3 ms) 5 ms max. (mean value approx. 2.50 ms)
Release (reset) time
(See note 2)
DPDT 3 ms max. (mean value approx. 1.20 ms) 5 ms max. (mean value approx. 2.50 ms)
Min. set/reset signal width DPDT 7 ms min.
Operating frequency Mechanical 36,000 operations/hour
Electrical 1,800 operations/hour (under rated load)
Insulation resistance (See note 3) 1,000 MΩ min. (at 500 VDC); except for set-reset
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
250 VAC, 50/60 Hz for 1 minute between set and reset coils
Surge withstand voltage 1,500 V (10 x 160 μs) (conforms to FCC Part 68)
Vibration Mechanical durability 10 to 55 Hz; 5 mm double amplitude
Malfunction durability 10 to 55 Hz; 3.3 mm double amplitude
Shock Mechanical durability 1,000 m/s2 (Approx. 100G
Malfunction durability DPDT: 500 m/s2 (Approx. 50 G)
Ambient temperature -40° to 70°C with no icing
Humidity 5% to 85% RH
Service life Mechanical 100 million operations min. (at 36,000 operations/hour)
Electrical 500,000 operations min. (at 1,800 operations/hr) See “Characteristic Data”
Weight DPDT Approx. 3.5 g
4PDT Approx. 6.0 g
Type Contact form Coil rating Contact ratings Number of test operations
G6A( )-274P-ST( )-US DPDT 1.5 to 48 VDC 1 A at 125 VAC (General Purpose)
2 A at 30 VDC (General Purpose)
0.6 A at 110 VDC (General Purpose)
6,000