ACA/ACB/ACC 14/3/03 1:55 pm Page 1 AC/DC Chassis Mount 15-25-50 Watts XPiQ inc. ACA/ACB/ACC Series Intelligent Design Quality Product * Efficiency to 85% * Adjustable Outputs * Internal EMI/RFI Filter * Isolated Outputs * Input/Output Protection * Compact Size/Light Weight Specification General Input Input Voltage Range Soft Start Input Filter Input Protection * 50 kHz Typical * * 75% Typical 50 Mohm (500 VDC) * ACA 250g, ACB 350g, ACC 470g See Table All Models Network Input Fuse * * 5% See Note 1 0.8% Environmental * 0.9% * 1% of VOUT & 50mV p-p Operating Temperature Storage Temperature * 0.03%/C * Zener Diode * Foldback Current Limit Output Voltage Adjustment Line Regulation (Full Input Range) Load Regulation (No Load-Full Load) Ripple & Noise (DC-100MHz) Temperature Coefficient Overvoltage Protection Short Circuit Protection Switching Frequency Efficiency Isolation (Input-Output-Case) * * * * Weight Hold Up Time * 10 ms Minimum Rise Time * 200 ms Maximum * 0C to 50C (no derating) * -20C to 85C * * 222 www.XP-iQ.com PH: 508 429.9883 FAX: 800 226.2100 Email: sales@xp-iq.com Holliston, MA 01746 USA ACA/ACB/ACC 14/3/03 1:55 pm Page 2 OUTPUT VOLTAGE & CURRENT RATINGS Series Output Code 01 02 03 04 Output Voltages 5 VDC 12 VDC 15 VDC 24 VDC +12 VDC -12 VDC +15 VDC -15 VDC 5 VDC +12 VDC -12 VDC 5 VDC +15 VDC -15 VDC 48 VDC 05 06 07 08 10 ACA/ACB/ACC 15/25/50 ACA Output Current(s) 3.00 A 1.20 A 1.00 A 0.62 A 0.75 A 0.50 A 0.50 A 0.50 A 1.80 A 0.15 A 0.15 A 1.80 A 0.15 A 0.15 A - ACB Output Current(s) 5.0 A 2.1 A 1.7 A 1.1 A 1.2 A 0.9 A 1.0 A 0.7 A 2.8 A 0.5 A 0.4 A 2.8 A 0.5 A 0.4 A 0.5 A ACC Output Current(s) 10.0 A 4.20 A 3.40 A 2.50 A 2.00 A (Pk 3.50 A) 1.70 A 1.70 A 1.30 A 5.00 A 0.83 A 0.83 A 5.00 A 0.65 A 0.65 A 1.00 A Single output models only, for optional 110/220 selectable inputs add suffix "S" to part number. Ordering Guide: Series/Input Code Example: ACC 102-50 Watt Series, 110 VAC Input, 12 Volt Output @ 4.2 AMPS Series Output Input Code Input Range Output Code ACA 15 Watts 25 Watts 90-132 VAC, 110-175 VDC (47-440 Hz) 180-264 VAC, 220-350 VDC (47-440 Hz) From Chart ACB 1 2 ACC 50 Watts Series Terminal 0 1 2 3 Single Output AC AC ACA Dual Output AC AC Case Gnd (FG) 4 - 5 6 7 - Triple Output Single Output Case Gnd (FG) Case Gnd (FG) AC AC Case Gnd (FG) AC AC -V3 -VOUT -V2 -VOUT Common +VOUT +VOUT - ACB Dual Output AC AC Filter Gnd (FG) Case Gnd (FG) Above ACC Dual Output Triple Output - Case Gnd (FG) AC AC AC AC AC AC Case Gnd (FG) -V3 +V2 V2,3 Common Triple Output Single Output Case Gnd (FG) Case Gnd (FG) AC AC -V3 - +V2 -V2,3 Common Filter Gnd (FG) Common - +V1 +V2 -VOUT -V2 +V2 -V1 -VOUT +V1 +V1 +VOUT +V1 +V1 - +VOUT -V1 -V1 - -V1 +V1 Mechanical Details Dimension A ACA ACB ACC 4.64 (118.0) 5.31 (135.0) 6.30 (160.0) B 3.15 (80.0) 3.35 (85.0) 3.78 (96.0) C 0.98 (25.0) 1.22 (31.0) 1.30 (33.0) D 2.76 (70.0) 2.76 (70.0) 3.94 (100.0) E 2.05 (52.0) 2.20 (56.0) 2.40 (61.0) F 1.30 (33.0) 1.28 (32.5) 1.18 (30.0) G 3.74 (95.0) 4.65 (118.0) H 0.28 (7.0) 0.39 (10.0) I 0.39 (10.0) 0.39 (10.0) 1. ACA Triple output - no adjustment ACB /ACC triple outputs - only 5 VDC adjustable www.XP-iQ.com PH: 508 429.9883 FAX: 800 226.2100 Email: sales@xp-iq.com Holliston, MA 01746 USA 112