Model Encoding / Order Information
Description
Factory control or automation apparatus
Test and measurement instrument
Laser related machine
Burn-in facility
RF application
Features Applications
24RSP - -500
Universal AC input / Full range
Built-in active PFC function
High efficiency up to 90.5%
Forced air cooling by built-in DC fan (Note.5)
Built-in remote ON-OFF control / remote sense / DC OK signal
Protections: Short circuit / Overload / Over voltage
/ Over temperature
3 years warranty
500W Single Output with PFC Function RSP-500 series
Series name
Output wattage
Output voltage (3.3V/4V/5V/12V/15V/24V/27V/48V)
RSP-500 is a 500W single output enclosed type AC/DC power supply. This series operates for 85~264VAC
input voltage and offers the models with the DC output mostly demanded from the industry. Each model is
cooled by the built-in fan with fan speed control, working for the temperature up to 70 . Moreover, RSP-500
provides vast design flexibility by equipping various built-in functions such as remote ON-OFF control,
remote sense,DC OK signal, etc.
5
Dimension
L
230
9.06
W
127
H
40.5(1U)
(1U)
mm
inch1.59
*
*
*
*
*
*
R33100
RoHS
CNS14336-1 UL62368-1 GB4943.1 TPTC004 IEC62368-1EN62368-1
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
File Name:RSP-500-SPEC 2020-04-13
SPECIFICATION
RSP-500-15
RSP-500-12 RSP-500-24 RSP-500-27 RSP-500-48RSP-500-5RSP-500-4RSP-500-3.3
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
Note.2
OUTPUT VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note.4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
REMOTE CONTROL
REMOTE SENSE
FAN CONTROL (Typ.)
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
PROTECTION
FUNCTION
15V12V 24V 27V 48V5V4V3.3V
33.4A41.7A 21A 18.6A 10.5A90A90A90A
0 ~ 33.4A0 ~ 41.7A 0 ~ 21A 0 ~ 18.6A 0 ~ 10.5A0 ~ 90A0 ~ 90A0 ~ 90A
501W500.4W 504W 502.2W 504W450W360W297W
150mVp-p150mVp-p 150mVp-p 150mVp-p 150mVp-p150mVp-p120mVp-p120mVp-p
4.5 ~ 5.5V3.6 ~ 4.3V2.8 ~ 3.6V 13.5 ~ 18V10 ~ 13.2V 20 ~ 26.4V 26 ~ 30V 41 ~ 56V
±1.0%±1.0% ±1.0% ±1.0% ±1.0%±2.0%±2.0%±2.0%
±0.3%±0.3% ±0.2% ±0.2% ±0.2%±0.5%±0.5%±0.5%
±0.5%±0.5% ±0.5% ±0.5% ±0.5%
±1.0%±1.0%±1.0%
1500ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load
18ms/230VAC 14ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.95/230VAC PF>0.98/115VAC at full load
88% 88% 89% 89.5% 90.5%
84%
83%81%
20A/115VAC 40A/230VAC
<2mA / 240VAC
105 ~ 130% rated output power
13.8 ~ 16.2V 18.8 ~ 21.8V 27.6 ~ 32.4V 32.9 ~ 38.3V 58.4 ~ 68V
5.75 ~ 6.75V4.5 ~ 5.3V3.8 ~ 4.5V
Protection type : , recovers automatically after fault condition is removedConstant current limiting
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
UL62368-1, TUV EN62368-1 EAC TP TC 004 , CCC GB4943.1 BSMI CNS14336-1approved
,
,
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020,GB/T 9254, CNS13438 Class B
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3 heavy industry level, criteria A, EAC TP TC 020
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
-30 ~ +70 (Refer to "Derating Curve")
POWER ON:open or 0~0.8VDC between RC+(Pin 4)&RC-(Pin3) on CN100
Compensate voltage drop on the load wiring up to 0.3V
RTH2 50 10 Fan on ; RTH2 40 10 Fan off (Fan always on for 3.3~5V,Fan ON/OFF control for 12~48V)≧℃±℃ ≦℃±℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
±℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
187.7K hrs min. MIL-HDBK-217F (25 )
230*127*40.5mm (L*W*H)
1.3Kg; 9pcs/12.7Kg/0.7CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. Fan always on for 3.3~5V,Fan ON/OFF control for 12~48V.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it
still meets EMC directives.For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than ℃℃
2000m(6500ft).
EMC IMMUNITY
EMC EMISSION
5.3A/115VAC 2.65 A/230VAC
4.2A/115VAC 2.1 A/230VAC
AC CURRENT (Typ.)
POWER OFF: 4~10VDC between RC+(Pin 4)&RC-(Pin3) on CN100
500W Single Output with PFC Function RSP-500 series
File Name:RSP-500-SPEC 2020-04-13
USP-225 seriesUSP-225 seriesSP-320 series
Mechanical Specification Case No.226A Unit:mm
500W Single Output with PFC Function
Block Diagram
Derating Curve Static Characteristics
AMBIENT TEMPERATURE ( )INPUT VOLTAGE (VAC) 60Hz
9085 95 100 115 135 155 175 195 230 264
LOAD (%)
LOAD (%)
10 20 30 40 50 60 70
20
40
60
80
100
-30 0 (HORIZONTAL)
fosc : 70KHz
PWM & PFC
CIRCUIT
DETECTION
O.L.P.
O.T.P.
EMI
FILTER
POWER
SWITCHING FILTERPFC
&&
RECTIFIERSRECTIFIERS +V
RC+
-V
RC-
I/P
FG
CONTROL
O.T.P.
O.V.P.
INRUSH
CURRENT
ACTIVE
LIMITING
FANFAN
CONTROL
ON/OFF
-S
+S
Air flow
direction
LED
13
24
+V ADJ.
SVR1
CN100
1
2
3
4
5
6
1
2
3
TB1
TB2
230
88
40 170
4-M4(Both Sides) L=5mm
6.5 6.5
2.5
39.3 159.7
15
16
RSP-500 series
90
100
80
70
60
50
40
HRS DF11-04DP-2DS or equivalent
Connector Pin No. Assignment (CN100) :
Pin No.
4
3
2
1
Assignment
-S
Mating Housing
HRS DF11-4DS
or equivalent
Terminal
HRS DF11-**SC
or equivalent
RC+
+S
RC-
AC Input Terminal
Pin No. Assignment (TB1)
Pin No.
1
3
2
Assignment
FG
AC/N
AC/L
DC Output Terminal
Pin No. Assignment (TB2)
Pin No.
1~3
4~6
Assignment
DC OUTPUT -V
DC OUTPUT +V
147
11 9.2
9.5 8.2
19 89
69
127
5-M4 L=4mm
6.9
13.3
12.5 18
40.5
File Name:RSP-500-SPEC 2020-04-13
The PSU can be turned ON/OFF by using the
"Remote Control" function.
The remote sensing compensates voltage drop on the
load wiring up to 0.3V
Function Description of CN100
Function Manual
1.Remote Control
2.Remote Sense
Pin No. Function Description
1
4
-S
RC+
Turns the output on and off by electrical or dry contact between pin 4 ( RC+) and pin 3 (RC-). 0~0.8VDC or open: Power ON, 4~10VDC: Power OFF.
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.3V.
Between RC-(pin3) and RC+(pin4) on CN100
SW OFF (0 ~ 0.8VDC) or open
SW ON (4 ~ 10V)
PSU Status
ON
OFF
3 RC- Return for RC+ signal input.
2+S
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.3V.
+V -V
RC-
-S +S
34
12
RC+
RC-
-S +S
34
12
RC+
+V -V
USP-225 seriesUSP-225 seriesSP-320 series
500W Single Output with PFC Function
RSP-500 series
LED
13
24
+V ADJ.
SVR1
CN100
1
2
3
4
5
6
2
3
TB1
TB2
1
SW
LOAD
-
+
I=6~20mA
External Power
Source
LED
13
24
+V ADJ.
SVR1
CN100
1
2
3
4
5
6
2
3
TB1
TB2
1
LOAD
-
+
Sense lines should
be twisted in pairs
CN100
-S
(pin1)
+S
(pin2)
CN100
File Name:RSP-500-SPEC 2020-04-13