PhotoMOS RELAYS GU (General Use) Type [1-Channel (Form B) Type] , Cross section of the normally-closed type of power MOS 6.40.05 .252.002 8.80.05 .346.002 3.90.2 .154.008 Passivation membrane Intermediate Source electrode Gate electrode insulating membrane 6.40.05 .252.002 , , 8.80.05 .346.002 4. Low-level off state leakage current The SSR has an off state leakage current of several milliamperes, whereas the PhotoMOS relay has only 100 pA even with the rated load voltage of 400 V. 3.60.2 .142.008 N+ P+ N+ N+ P+ N+ Gate oxidation membrane N- Drain electrode mm inch FEATURES 1. Low on resistance for normallyclosed type This has been realized thanks to the builtin MOSFET processed by our proprietary method, DSD (Double-diffused and Selective Doping) method. N+ 2. Controls low-level analog signals PhotoMOS relays feature extremely low closed-circuit offset voltage to enable control of low-level analog signals without distortion. 3. High sensitivity, low ON resistance Can control a maximum 0.15 A load current with a 5 mA input current. TYPICAL APPLICATIONS * Telepone equipment (Dial pulse) * Measuring equipment TYPES Part No. Output rating* Type AC/DC type I/O isolation voltage 1,500 V AC Load voltage Load current 400 V 120 mA Through hole terminal Tape and reel packing style Picked from the Picked from the 1/2/3-pin side 4/5/6-pin side Tube packing style AQV414 Packing quantity Surface-mount terminal AQV414A AQV414AX AQV414AZ Tube Tape and reel 1 tube contains 50 pcs. 1 batch contains 500 pcs. 1,000 pcs. *Indicate the peak AC and DC values. Note: For space reasons, the package type indicator "X" and "Z" are omitted from the seal. RATING 1. Absolute maximum ratings (Ambient temperature: 25C 77F) Item Input Output LED forward current LED reverse voltage Peak forwrd current Power dissipation Load voltage (peak AC) Continuous load current Peak load current Power dissipation Total power dissipation I/O isolation voltage Operating Temperature limits Storage Type of Symbol connection IF VR IFP Pin VL A IL B C Ipeak Pout PT Viso Topr Tstg AQV414(A) 50 mA 3V 1A 75 mW 400 V 0.12 A 0.13 A 0.15 A 0.3 A 500 mW 550 mW 1,500 V AC -40C to +85C -40F to +185F -40C to +100C -40F to +212F Remarks f = 100 Hz, Duty factor = 0.1% A connection: Peak AC, DC B,C connection: DC A connection: 100 ms (1 shot), VL = DC Non-condensing at low temperatures 483 AQV414 2. Electrical characteristics (Ambient temperature: 25C 77F) Type of Symbol connection Item Typical Maximum Minimum LED reverse (ON) current Typical Typical LED dropout voltage Maximum Typical LED operate (OFF) current Input Maximum AQV414(A) 1.0 mA 3.0 mA 0.4 mA 0.95 mA 1.14 V (1.25 V at IF= 50 mA) 1.5 V 26 IFoff -- IFon -- VF -- Ron A 50 Ron B 25 Maximum Output Ron C 12.5 ILeak -- 1 A Maximum Switching speed Transfer characteristics Maximum Typical Maximum Typical Maximum Typical Maximum Operate (OFF) time* Toff -- Reverse (ON) time* Ton -- I/O capacitance Ciso -- Initial I/O isolation resistance Riso -- IL= 120 mA IF= 5 mA IF = 0 mA IL= 120 mA Within 1 s on time IF= 0 mA IL= 120 mA Within 1 s on time IF= 0 mA IL= 120 mA Within 1 s on time IF= 5 mA VL = 400 V 10 Typical Off state leakage current IL= 120 mA 20 Typical On resistance Condition Minimum 0.47 ms 1.0 ms 0.28 ms 1.0 ms 0.8 pF 1.5 pF IF = 0 mA 5 mA IL = 120 mA IF= 5 mA 0 mA IL = 120 mA f = 1 MHz VB = 0 1,000 M Note: Recommendable LED forward current IF= 5 mA. *Operate/Reverse time 500 V DC For type of connection, see Page 445. Input Output 10% 90% Toff Ton For Dimensions, see Page 440. For Schematic and Wiring Diagrams, see Page 445. For Cautions for Use, see Page 449. REFERENCE DATA 2. On resistance vs. ambient temperature characteristics 3. Operate (OFF) time vs. ambient temperature characteristics Allowable ambient temperature: -40C to +85C -40F to +185F Type of connection: A Measured portion: between terminals 4 and 6; LED current: 0 mA; Continuous load current: 120 mA (DC) LED current: 5mA; Load voltage: 400 V (DC); Continuous load current: 120 mA (DC) 60 120 50 100 80 60 30 -20 0 20 40 60 8085 100 Ambient temperature, C 0 1.0 0.8 0.6 0.4 0.2 10 20 484 40 20 40 0 -40 1.2 Operate (OFF) time, ms 140 On resistance, Load current, mA 1. Load current vs. ambient temperature characteristics -40 -20 0 20 40 60 8085 Ambient temperature, C 0 -40 -20 0 20 40 60 8085 Ambient temperature, C AQV414 4. Reverse (ON) time vs. ambient temperature characteristics 5. LED operate (OFF) current vs. ambient temperature characteristics 6. LED reverse (ON) current vs. ambient temperature characteristics LED current: 5 mA; Load voltage: 400 V (DC); Continuous load current: 120 mA (DC) Load voltage: 400 V (DC); Continuous load current: 120 mA (DC) Load voltage: 400 V (DC); Continuous load current: 120 mA (DC) 1.0 0.8 0.6 0.4 5 4 3 2 1 0.2 -40 -20 0 0 20 40 60 8085 Ambient temperature, C -40 -20 8. Voltage vs. current characteristics of output at MOS portion LED current: 5 to 50 mA Measured portion: between terminals 4 and 6; Ambient temperature: 25C 77F 2 -40 -20 0 20 40 60 8085 Ambient temperature, C 9. Off state leakage current Measured portion: between terminals 4 and 6; LED current: 5 mA; Ambient temperature: 25C 77F 120 Current, mA 1.5 LED dropout voltage, V 3 0 0 20 40 60 8085 Ambient temperature, C 7. LED dropout voltage vs. ambient temperature characteristics 1.4 50mA 30mA 1.3 20mA 10mA 5mA 1.2 100 80 60 40 20 -6 -5 -4 -3 -2 -1 1 2 3 4 5 6 -20 Voltage, V -40 1.1 -60 10-3 10-6 10-9 -80 1.0 10 -12 -100 0 4 1 Off state leakage current, A 0 5 LED reverse (ON) current, mA LED operate (OFF) curremt, mA Reverse (ON) time, ms 1.2 -40 -20 -120 0 20 40 60 8085 100 Ambient temperature, C 0 20 40 60 80 Load voltage, V 100 11. LED forward current vs. reverse (ON) time characteristics 12. Applied voltage vs. output capacitance characteristics Measured portion: between terminals 4 and 6; Load voltage: 400 V (DC); Continuous load current: 120 mA (DC); Ambient temperature: 25C 77F Measured portion: between terminals 4 and 6; Load voltage: 400 V (DC); Continuous load current: 120 mA (DC); Ambient temperature: 25C 77F Measured portion: between terminals 4 and 6; Frequency: 1 MHz; Ambient temperature: 25C 77F 1.2 2.5 1.0 2.0 1.5 1.0 9/1/2000 100 0.8 0.6 0.4 0.2 0.5 0 120 Output capacitance, pF 3.0 Reverse (ON) time, ms Operate (OFF) time, ms 10. LED forward current vs. operate (OFF) time characteristics 10 20 30 40 50 LED forward current, mA 60 0 80 60 40 20 10 20 30 40 50 LED forward current, mA 60 0 10 20 30 40 50 Applied voltage, V 60 All Rights Reserved, (c) Copyright Matsushita Electric Works, 485 Ltd. Go To Online Catalog