UNISONIC TECHNOLOGIES CO., LTD
MBR0530 DIODE
www.unisonic.com.tw 1 of 3
Copyright © 2011 Unisonic Technologies Co., Ltd QW-R601-014,B
SCHOTTKY RECTIFIER
FEATURES
* For surface mounted applications
* Low forward voltage drop (VF=0.37V Typ. at 0.1A)
* Guard ring for transient and ESD protection
SOD-123
+
-
SOD-323
+
-
ORDERING INFORMATION
Ordering Number
Lead Free Halogen Free Package Packing
MBR0530L-CA2-R MBR0530G-CA2-R SOD-123 Tape Reel
MBR0530L-CB2-R MBR0530G-CB2-R SOD-323 Tape Reel
MARKING
MBR0530 DIODE
UNISONIC TECHNOLOGIES CO., LTD 2 of 3
www.unisonic.com.tw QW-R601-014,B
ABSOLUTE MAXIMUM RATINGS (Ta=25)
PARAMETER SYMBOL RATINGS UNIT
Maximum Repetitive Peak Reverse Voltage VRRM 30 V
Maximum DC Blocking Voltage VR 30 V
Working Peak Reverse Voltage VRWM 30 V
Maximum RMS Reverse Voltage VR(RMS) 21 V
Maximum Voltage Rate of Change (Rated VR) dv/dt 1000 V/μs
Average Rectified Forward Current IOUT 500 mA
Non-Repetitive Peak Forward Surge Current IFSM 5.5 A
Power Dissipation PD 410 mW
Storage Temperature TSTG -65 ~ +150
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
THERMAL DATA
PARAMETER SYMBOL RATINGS UNIT
Junction to Ambient θJA 244
/W
ELECTRICAL CHARACTERISTICS (TA=25, unless otherwise specified)
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNIT
Reverse Breakdown Voltage BVR I
R=130μA 30 V
VF1 I
F=0.1A 0.375
Forward Voltage Drop VF2 I
F=0.5A 0.430 V
IR1 V
R=15V 20
Reverse Leakage Current IR2 V
R=30V 130 μA
Total Capacitance CT V
R=1V, f=1MHz 170 pF
Typical Reverse Recovery Time tRR IF=IR=10mA, RL=100,
recover to 0.1 x IR 4 ns
MBR0530 DIODE
UNISONIC TECHNOLOGIES CO., LTD 3 of 3
www.unisonic.com.tw QW-R601-014,B
TYPICAL CHARACTERISTICS
Total Capacitance, CT (pF)
Instantaneous Forward Current, IF(A)
0
0
0.2
0.4
0.6
0.8
Average Rectified Forward Current, IOUT (A)
50 125 150
Lead Temperature, TL ()
25 75 100
Forward Current Derating Curve
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.