PC3SF11YVZA/PC3SF11YVZB PC3SF11YVZA/ PC3SF11YVZB Reinforced Insulation Type Phototriac Coupler for Triggering Features Outline Dimensions 1. Isolation voltage between input and output (Viso (rms):5kV) 2. High critical rate of rise of OFF-state voltage (dV/dt:MIN. 1 000V/s) 3. Internal isolation distance (0.4mm or more) 4. Recognized by UL (File No. E64380) Approved by VDE (VDE0884, File No.127413) Approved by BSI (BS415, File No.6690, BS7002, File No.7421) Approved by SEMKO (File No.0033029/01-04) Approved by DEMKO (File No.310107-01) Approved by FIMKO (File No.15795) PC3SF11YVZA, PC3SF11YVZB are for 200V line Anode mark 2 3 Absolute Maximum Ratings 2 3 Pin 5 Anode Cathode NC 2 3 7.620.3 2.5MIN. 3.50.3 1 1 4 0.60.2 1.20.3 0.50.1 for AC 200V line PC3SF11YVZA PC3SF11YVZB 5 NC 7.120.3 Model Line-up 6 6.50.3 3SF11 1 1. Home appliances 2. OA equipment, FA equipment 3. SSRs 10.160.5 4 5 6 Anode, Cathode No external connection Anode, Cathode is not allowed external connection (Ta=25C) Parameter Symbol Rating 50 Forward current IF Input Reverse voltage VR 6 *1 RMS ON-state current IT (rms) 0.1 Output Peak one cycle surge current Isurge 1.2 (50Hz sine wave) Repetitive peak OFF-state voltage VDRM 600 *2 Isolation voltage Viso (rms) 5 Operating temperature -30 to +100 Topr Storage temperature -55 to +125 Tstg Soldering temperature Tsol 260 (For 10s) *1 Internal connection diagram 2.540.25 Applications Minimum trigger current (IFT[MAX.]) 10mA 7mA (Unit : mm) Unit mA V A A V kV C C C *1 The derating factors of absolute maximum ratings due to ambient temperature are shown in Fig.1, 2 *2 AC for 1 min, 40 to 60%RH, f=60Hz Notice In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. Internet Internet address for Electronic Components Group http://sharp-world.com/ecg/ PC3SF11YVZA/PC3SF11YVZB Electro-optical Characteristics Parameter Symbol Forward voltage VF Reverse current IR Repetitive peak OFF-state current IDRM VT ON-state voltage IH Holding current Critical rate of rise of OFF-state voltage dV/dt Input Output PC3SF11YVZA PC3SF11YVZB Minimum trigger current Transfer characteristics Isolation resistance Turn-on time IFT VD=6V, RL=100 RISO ton DC=500V, 40 to 60%RH VD=6V, RL=100, IF=20mA Fig.1 RMS ON-state Current vs. Ambient Temperature 175 70 150 60 125 100 75 50 25 0 MIN. - - - - 0.1 1 000 - - 5x1010 - TYP. 1.2 - - - - 2 000 - - 1011 - MAX. 1.4 10-5 10-6 2.5 3.5 - 10 7 - 100 (Ta=25C) Unit V A A V mA V/s mA s Fig.2 Forward Current vs. Ambient Temperature Forward current IF (mA) RMS ON-state current Ir (rms) (mA) Conditions IF=20mA VR=3V VD=VDRM IT=0.1A VD=6V - VD=1/2 * VDRM 50 40 30 20 10 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Ambient temperature Ta (C) Ambient temperature Ta (C) Fig.3 Forward Current vs. Forward Voltage Fig.4 Minimum Trigger Current vs. Ambient Temperature 10 Minimum trigger current IFT (mA) Ta=75C Forward current IF (mA) VD=6V RL=100 9 100 50 50C 20 25C 0C 10 5 -25C 2 8 7 6 5 4 3 2 1 1 0.9 1 1.1 1.2 1.3 Forward voltage VF (V) 1.4 1.5 0 -40 -20 0 20 40 60 Ambient temperature Ta (C) 80 100 PC3SF11YVZA/PC3SF11YVZB Fig.5 ON-state Voltage vs. Ambient Temperature Fig.6 Holding Current vs. Ambient Temperature 10 IT=100mA 2.4 VD=6V Holding current IH (mA) ON-state voltage VT (V) 2.2 2 1.8 1.6 1.4 1 1.2 1 -40 -20 0 20 40 60 80 100 0.1 -40 120 -20 Fig.7 Repetitive Peak OFF-state Current vs. Ambient Temperature Relative repetitive peak OFF-state voltage VDRM (Tj=Ta) / VDRM (Tj=25C) Repetitive peak OFF-state current IDRM (A) 0.1 0.01 0.001 -20 0 20 40 60 80 100 Ambient temperature Ta (C) 60 80 100 1 000 VD=6V RL=100 Ta=25C 100 10 10 Forward current IF (mA) 1.2 1.1 1 0.9 0.8 0.7 -40 -20 0 20 40 60 Ambient temperature Ta (C) Fig.9 Turn-on Time vs. Forward Current Turn-on time tON (S) 40 1.3 VD=600V 1 20 Fig.8 Relative Repetitive Peak OFF-state Voltage vs. Ambient Temperature 1 0.0001 -40 0 Ambient temperature Ta (C) Ambient temperature Ta (C) 100 80 100 NOTICE The circuit application examples in this publication are provided to explain representative applications of SHARP devices and are not intended to guarantee any circuit design or license any intellectual property rights. SHARP takes no responsibility for any problems related to any intellectual property right of a third party resulting from the use of SHARP's devices. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. SHARP reserves the right to make changes in the specifications, characteristics, data, materials, structure, and other contents described herein at any time without notice in order to improve design or reliability. Manufacturing locations are also subject to change without notice. Observe the following points when using any devices in this publication. SHARP takes no responsibility for damage caused by improper use of the devices which does not meet the conditions and absolute maximum ratings to be used specified in the relevant specification sheet nor meet the following conditions: (i) The devices in this publication are designed for use in general electronic equipment designs such as: - - - Personal computers - -- Office automation equipment - -- Telecommunication equipment [terminal] - - - Test and measurement equipment - - - Industrial control - -- Audio visual equipment - -- Consumer electronics (ii) Measures such as fail-safe function and redundant design should be taken to ensure reliability and safety when SHARP devices are used for or in connection with equipment that requires higher reliability such as: - -- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.) - - - Traffic signals - - - Gas leakage sensor breakers - - - Alarm equipment - -- Various safety devices, etc. (iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely high level of reliability and safety such as: - - - Space applications - -- Telecommunication equipment [trunk lines] - -- Nuclear power control equipment - -- Medical and other life support equipment (e.g., scuba). Contact a SHARP representative in advance when intending to use SHARP devices for any "specific" applications other than those recommended by SHARP or when it is unclear which category mentioned above controls the intended use. If the SHARP devices listed in this publication fall within the scope of strategic products described in the Foreign Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export such SHARP devices. This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. Express written permission is also required before any use of this publication may be made by a third party. Contact and consult with a SHARP representative if there are any questions about the contents of this publication.