General Description
The MAX700/MAX701/MAX702 are supervisory circuits
used to monitor the power supplies in microprocessor
(µP) and digital systems. The RESET/RESET outputs of
the MAX700/MAX701/MAX702 are guaranteed to be in
the correct state for VCC voltages down to +1V (Figure 4).
They provide excellent circuit reliability and low cost by
eliminating external components and adjustments when
used with +5V-powered circuits.
The MAX702 is the simplest part in the family. When
VCC falls to 4.65V, RESET goes low. The MAX702 also
provides a debounced manual reset input. The
MAX701 performs the same functions but has both
RESET and RESET outputs. Their primary function is to
provide a system reset. Accordingly, an active reset
signal is supplied for low supply voltages and for at
least 200ms after the supply voltage reaches its operat-
ing value.
In addition to the features of the MAX701 and MAX702,
the MAX700 provides preset or adjustable voltage
detection so thresholds other than 4.65V can be select-
ed, and adjustable hysteresis. All parts are supplied in
8-pin PDIP and Narrow SO packages in commercial
and extended temperature ranges.
Applications
Computers
Controllers
Intelligent Instruments
Automotive Systems
Critical µP Power Monitoring
Features
Min 200ms RESET Pulse on Power-Up, Power-
Down, and During Low-Voltage Conditions
Reset Threshold Factory Trimmed for +5V
Systems
No External Components or Adjustments with
+5V-Powered Circuits
Debounced Manual Reset Input
Preset or Adjustable Voltage Detection (MAX700)
Adjustable Hysteresis (MAX700)
8-Pin PDIP and Narrow SO Packages
MAX700/MAX701/MAX702
Power-Supply Monitor with Reset
________________________________________________________________
Maxim Integrated Products
1
19-2690; Rev 2; 12/07
For pricing delivery, and ordering information please contact Maxim Direct at 1-888-629-4642,
or visit Maxim’s website at www.maxim-ic.com.
RESET
RESETGND
1
2
8
7
VCC
CTLSENSE
HYST
MR
DIP/SO
TOP VIEW
3
4
6
5
MAX700
RESET
RESET
GND
1
2
8
7
VCC
N.C.N.C.
N.C.
MR
DIP/SO
3
4
6
5
MAX701
N.C.
N.C.
RESET
GND
1
2
8
7
N.C.
VCC
N.C.
MR
DIP/SO
3
4
6
5
MAX702
Pin Configurations
Ordering Information
PART* TEMP RANGE PIN-PACKAGE
MAX700C/D 0°C to +70°C Dice
MAX700CPA 0°C to +70°C 8 PDIP
MAX700CSA 0°C to +70°C 8 Narrow SO
MAX700EPA -40°C to +85°C 8 PDIP
MAX700ESA -40°C to +85°C 8 Narrow SO
MAX701C/D 0°C to +70°C Dice
MAX701CPA 0°C to +70°C 8 PDIP
MAX701CSA 0°C to +70°C 8 Narrow SO
MAX701EPA -40°C to +85°C 8 PDIP
MAX701ESA -40°C to +85°C 8 Narrow SO
MAX702C/D 0°C to +70°C Dice
MAX702CPA 0°C to +70°C 8 PDIP
MAX702CSA 0°C to +70°C 8 Narrow SO
MAX702EPA -40°C to +85°C 8 PDIP
MAX702ESA -40°C to +85°C 8 Narrow SO
*
Devices in PDIP and SO packages are available in both lead-
ed and lead-free packaging. Specify lead free by adding the +
symbol at the end of the part number when ordering.
MAX700/MAX701/MAX702
Power-Supply Monitor with Reset
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
VCC ......................................................................-0.3V to +15.5V
Voltage (with respect to GND) at RESET, RESET,
HYST, CTL, SENSE ............................................-0.3V to VCC
Operating Temperature Range
C Suffix .............................................................0°C to +70°C
E Suffix...........................................................-40°C to +85°C
Rate of Rise, VCC ............................................................100V/µs
Power Dissipation, Any Package .....................................380mW
Storage Temperature Range .............................-55°C to +150°C
Lead Temperature (soldering, 10s)..................................+300°C
ELECTRICAL CHARACTERISTICS
(VCC = +5V, CTL = GND on MAX700, TA= +25°C, unless otherwise noted.)
PARAMETER CONDITIONS MIN TYP MAX UNITS
V
CC
Monitor Voltage Range
(MAX700 Only) T
A
= T
MIN
to T
MAX
, CTL = V
CC
315V
Min V
CC
for Valid Reset Output,
Declining Supply T
A
= T
MIN
to T
MAX
, RESET 0.4V when sinking 1mA 1.5 1 V
Supply Current 100 200 µA
Power-up 4.50 4.65 4.75
Reset Threshold T
A
= T
MIN
to T
MAX
Power-down 4.50 4.62 4.75 V
Internal Hysteresis HYST not connected 30 mV
Reset Output Pulse Width 200 350 500 ms
RESET Fall Time MAX700/MAX701 only, C
LOAD
= 100pF 200 ns
No reset 10 1
V
CC
Pulse Duration Guaranteeing 5V to 4V V
CC
pulse Reset 100 10 µs
MR Input Threshold 0.7 V
MR Pullup Current -5 -30 µA
MAX700
I
SINK
= 3.2mA, V
CC
= 5V 0.4
RESET Output Low I
SINK
= 1.6mA, V
CC
= 3V 0.4 V
I
SOURCE
= 3.2mA, V
CC
= 4.25V V
CC
-
0.4
I
SOURCE
= 1.6mA, V
CC
= 3V V
CC
-
0.4
RESET Output High
I
SOURCE
= 0.5mA, V
CC
= 1.5V V
CC
-
0.4
V
I
SINK
= 16mA, V
CC
= 4.25V 0.4
I
SINK
= 1.6mA, V
CC
= 3V 0.4RESET Output Low
I
SINK
= 0.4mA, V
CC
= 1.5V 0.4
V
I
SOURCE
= 3.2mA, V
CC
= 5V V
CC
-
0.4
RESET Output High
I
SOURCE
= 1.6mA, V
CC
= 3V V
CC
-
0.4
V
MAX700/MAX701/MAX702
Power-Supply Monitor with Reset
_______________________________________________________________________________________ 3
PARAMETER CONDITIONS MIN TYP MAX UNITS
MAX701
RESET Output Low ISINK = 16mA, VCC = 5V 0.4 V
ISOURCE = 3.2mA, VCC = 4.25V VCC -
0.4
ISOURCE = 1.6mA, VCC = 3V VCC -
0.4
RESET Output High
ISOURCE = 0.5mA, VCC = 1.5V VCC -
0.4
V
ISINK = 3.2mA, VCC = 4.25V 0.4
ISINK = 1.6mA, VCC = 3V 0.4RESET Output Low
ISINK = 0.4mA, VCC = 1.5V 0.4
V
RESET Output High ISOURCE = 3.2mA, VCC = 5V VCC -
0.4 V
MAX702
ISINK = 3.2mA, VCC = 4.25V 0.4
ISINK = 1.6mA, VCC = 3V 0.4
RESET Output Low
ISINK = 0.4mA, VCC = 1.5V 0.4
V
RESET Output High ISOURCE = 3.2mA, VCC = 5V VCC -
0.4 V
MAX700 ONLY (CTL = VCC, unless otherwise noted)
SENSE Input Threshold TA = TMIN to TMAX 1.25 1.29 1.35 V
SENSE Input Current 0.1 nA
HYST Input On-Resistance 0.5 k
CTL Input Threshold 2V
CTL Pulldown Current 30 100 µA
ELECTRICAL CHARACTERISTICS (continued)
(VCC = +5V, CTL = GND on MAX700, TA= +25°C, unless otherwise noted.)
MAX700/MAX701/MAX702
Power-Supply Monitor with Reset
4 _______________________________________________________________________________________
Pin Description
PIN
MAX700 MAX701 MAX702 NAME FUNCTION
111MR
Input for Manual Pushbutton Reset. Has internal 5µA pullup. Low input activates the
RESET/RESET outputs.
2 SENSE
The voltage-sense input when CTL = VCC. Its threshold is 1.29V. SENSE always
remains connected to the internal comparator. So, when VCC is being monitored
internally (CTL = GND), SENSE should be left open circuit.
3 HYST
Normally NOT used when voltage is monitored through VCC (CTL = GND). When
monitoring through SENSE (CTL = VCC), HYST allows hysteresis to be added,
reducing noise and spurious reset activity (Figure 3). HYST turns on 5µs before the
RESET/RESET outputs are activated, and its on-resistance to GND is typically 1k.
4 4 3 GND Ground
567RESET Goes low when VCC falls below 4.65V, or when CTL = VCC on the MAX700 goes low
when SENSE falls below 1.29V.
6 5 RESET Inverted Version of RESET
7 CTL When C TL = GN D , V
C C
i s m oni tor ed b y the r eset ci r cui t. When C TL = V
C C
, V
C C
i s i g nor ed
and S E N S E i s m oni tor ed , al l ow i ng the thr eshol d to b e set w i th exter nal r esi stor s.
882V
CC Chip Power and +5V Sensing Input (When CTL = GND on MAX700)
2, 3, 7 4, 5, 6, 8 N.C. No Connection
MAX700/MAX701/MAX702
Power-Supply Monitor with Reset
_______________________________________________________________________________________ 5
Figure 1. MAX700 Block Diagram
RESET
1M
1.29V REF
OSC
RC
R
R
COMPARATOR
RESET
GND
1
2
8
7
VCC
CTL
SENSE
HYST
150k
MR
3
4
6
5
MAX700
GND
1
2
8
7
SENSE
MANUAL
RESET
BUTTON
HYST
MR
3
4
6N.C.
N.C.
TO µP
+5V
5
MAX700
RESET
RESET
VCC
CTL
GND
1
2
8
7
SENSE
MANUAL
RESET
BUTTON
HYST
MR
3
4
6N.C.
R1
R3R2
VIN
TO µP
VIN 3V TO 15V
VL = LOWER VOLTAGE THRESHOLDR1 = R2( VL - 1)
1.29
R3 = VTR1
VU - VLVU = UPPER VOLTAGE THRESHOLD
HYSTERESIS = VU - VL
5
MAX700
RESET
RESET
VCC
CTL RESET
0V
0V
2V/div
2V/div
1s/div
VCC
Figure 4. Typical MAX700/MAX701/MAX702 RESET Output vs. VCC
Figure 2. MAX700 Typical Connection Diagram
Figure 3. MAX700 Connected for External Senses and
Hysteresis
Figure 4 shows the RESET output of the MAX700/
MAX701/MAX702 in the correct state for VCC voltages
down to 0V. Note the effect of the built-in hysteresis on
the trigger lever of RESET.
Package Information
For the latest package outline information, go to
www.maxim-ic.com/packages.
MAX700/MAX701/MAX702
Power-Supply Monitor with Reset
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
6
_____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600
© 2008 Maxim Integrated Products is a registered trademark of Maxim Integrated Products, Inc.
Revision History
REVISION
NUMBER
REVISION
DATE DESCRIPTION PAGES
CHANGED
0 3/90 Initial release
1 11/05 Added lead-free information to the Ordering Information table. 1
2 12/07 Updated Pin Description table. 4