CD54AC74, CD74AC74
DUAL POSITIVE-EDGE-TRIGGERED D-TYPE FLIP-FLOPS
WITH CLEAR AND PRESET
SCHS231D – SEPTEMBER 1998 – REVISED DECEMBER 2002
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
D
AC Types Feature 1.5-V to 5.5-V Operation
and Balanced Noise Immunity at 30% of the
Supply
D
Speed of Bipolar F, AS, and S, With
Significantly Reduced Power Consumption
D
Balanced Propagation Delays
D
±24-mA Output Drive Current
– Fanout to 15 F Devices
D
SCR-Latchup-Resistant CMOS Process and
Circuit Design
D
Exceeds 2-kV ESD Protection Per
MIL-STD-883, Method 3015
description/ordering information
The ’AC74 dual positive-edge-triggered devices are D-type flip-flops.
A low level at the preset (PRE) or clear (CLR) inputs sets or resets the outputs, regardless of the levels of the
other inputs. When PRE and CLR are inactive (high), data at the data (D) input meeting the setup time
requirements is transferred to the outputs on the positive-going edge of the clock pulse. Clock triggering occurs
at a voltage level and is not related directly to the rise time of the clock pulse. Following the hold-time interval,
data at the D input can be changed without affecting the levels at the outputs.
ORDERING INFORMATION
TAPACKAGEORDERABLE
PART NUMBER TOP-SIDE
MARKING
PDIP – E Tube CD74AC74E CD74AC74E
55°Cto125°C
SOIC M
Tube CD74AC74M
AC74M
55°C
to
125°C
SOIC
M
Tape and reel CD74AC74M96
AC74M
CDIP – F Tube CD54AC74F3A CD54AC74F3A
Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines
are available at www.ti.com/sc/package.
FUNCTION TABLE
(each flip-flop)
INPUTS OUTPUTS
PRE CLR CLK D Q Q
L H X X H L
HLXXLH
LLXXH
H
H H HHL
H H LLH
H H L X Q0Q0
This configuration is nonstable; that is, it does not
persist when PRE or CLR returns to its inactive
(high) level.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
Copyright 2002, Texas Instruments Incorporated
1
2
3
4
5
6
7
14
13
12
11
10
9
8
1CLR
1D
1CLK
1PRE
1Q
1Q
GND
VCC
2CLR
2D
2CLK
2PRE
2Q
2Q
CD54AC74 ...F PACKAGE
CD74AC74 ...E OR M PACKAGE
(TOP VIEW)
On products compliant to MIL-PRF-38535, all parameters are tested
unless otherwise noted. On all other products, production
processing does not necessarily include testing of all parameters.
CD54AC74, CD74AC74
DUAL POSITIVE-EDGE-TRIGGERED D-TYPE FLIP-FLOPS
WITH CLEAR AND PRESET
SCHS231D SEPTEMBER 1998 REVISED DECEMBER 2002
2POST OFFICE BOX 655303 DALLAS, TEXAS 75265
logic diagram, each flip-flop (positive logic)
TG
C
C
TG
C
C
TG
C
C
C
TG
C
C
PRE
CLK
D
CLR
Q
Q
C
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, VCC 0.5 V to 6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, IIK (VI < 0 or VI > VCC) (see Note 1) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, IOK (VO < 0 or VO > VCC) (see Note 1) ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, IO (VO = 0 to VCC) ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous current through VCC or GND ±100 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θJA (see Note 2): E package 80°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M package 86°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, Tstg 65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only , and
functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may af fect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
CD54AC74, CD74AC74
DUAL POSITIVE-EDGE-TRIGGERED D-TYPE FLIP-FLOPS
WITH CLEAR AND PRESET
SCHS231D SEPTEMBER 1998 REVISED DECEMBER 2002
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
recommended operating conditions (see Note 3)
TA = 25°C55°C to
125°C40°C to
85°CUNIT
MIN MAX MIN MAX MIN MAX
VCC Supply voltage 1.5 5.5 1.5 5.5 1.5 5.5 V
VCC = 1.5 V 1.2 1.2 1.2
VIH High-level input voltage VCC = 3 V 2.1 2.1 2.1 V
VCC = 5.5 V 3.85 3.85 3.85
VCC = 1.5 V 0.3 0.3 0.3
VIL Low-level input voltage VCC = 3 V 0.9 0.9 0.9 V
VCC = 5.5 V 1.65 1.65 1.65
VIInput voltage 0 VCC 0 VCC 0 VCC V
VOOutput voltage 0 VCC 0 VCC 0 VCC V
IOH High-level output current VCC = 4.5 V to 5.5 V 24 24 24 mA
IOL Low-level output current VCC = 4.5 V to 5.5 V 24 24 24 mA
t/v
In
p
ut transition rise or fall rate
VCC = 1.5 V to 3 V 50 50 50
ns/V
t/v
Input
transition
rise
or
fall
rate
VCC = 3.6 V to 5.5 V 20 20 20
ns/V
NOTE 3: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER TEST CONDITIONS V
CC
TA = 25°C55°C to
125°C40°C to
85°CUNIT
CC
MIN MAX MIN MAX MIN MAX
1.5 V 1.4 1.4 1.4
IOH = 50 µA3 V 2.9 2.9 2.9
4.5 V 4.4 4.4 4.4
VOH VI = VIH or VIL IOH = 4 mA 3 V 2.58 2.4 2.48 V
IOH = 24 mA 4.5 V 3.94 3.7 3.8
IOH = 50 mA5.5 V 3.85
IOH = 75 mA5.5 V 3.85
1.5 V 0.1 0.1 0.1
IOL = 50 µA3 V 0.1 0.1 0.1
4.5 V 0.1 0.1 0.1
VOL VI = VIH or VIL IOL = 12 mA 3 V 0.36 0.5 0.44 V
IOL = 24 mA 4.5 V 0.36 0.5 0.44
IOL = 50 mA5.5 V 1.65
IOL = 75 mA5.5 V 1.65
IIVI = VCC or GND 5.5 V ±0.1 ±1±1µA
ICC VI = VCC or GND, IO = 0 5.5 V 4 80 40 µA
Ci10 10 10 pF
T est one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 50- transmission-line drive capability at 85°C and 75- transmission-line drive capability at 125°C.
CD54AC74, CD74AC74
DUAL POSITIVE-EDGE-TRIGGERED D-TYPE FLIP-FLOPS
WITH CLEAR AND PRESET
SCHS231D SEPTEMBER 1998 REVISED DECEMBER 2002
4POST OFFICE BOX 655303 DALLAS, TEXAS 75265
timing requirements over recommended operating free-air temperature range, VCC = 1.5 V (unless
otherwise noted)
55°C to
125°C40°C to
85°CUNIT
MIN MAX MIN MAX
fclock Clock frequency 9 10 MHz
t
Pulse duration
PRE or CLR low 50 44
ns
t
w
Pulse
duration
CLK 56 49
ns
t
Setup time
Data 44 39 ns
t
su
S
e
t
up
ti
me PRE or CLR inactive ns
thHold time Data after CLK0 0 ns
trec Recovery time, before CLKCLRor PRE34 30 ns
timing requirements over recommended operating free-air temperature range, VCC = 3.3 V ± 0.3 V
(unless otherwise noted) (see Figure 1)
55°C to
125°C40°C to
85°CUNIT
MIN MAX MIN MAX
fclock Clock frequency 79 90 MHz
t
Pulse duration
PRE or CLR low 5.6 4.9
ns
t
w
Pulse
duration
CLK 6.3 5.5
ns
t
Setup time
Data 4.9 4.3 ns
t
su
S
e
t
up
ti
me PRE or CLR inactive ns
thHold time Data after CLK0 0 ns
trec Recovery time, before CLKCLRor PRE4.7 4.1 ns
timing requirements over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V
(unless otherwise noted) (see Figure 1)
55°C to
125°C40°C to
85°CUNIT
MIN MAX MIN MAX
fclock Clock frequency 110 125 MHz
t
Pulse duration
PRE or CLR low 4 3.5
ns
t
w
Pulse
duration
CLK 4.5 3.9
ns
t
Setup time
Data 3.5 3.1 ns
t
su
S
e
t
up
ti
me PRE or CLR inactive ns
thHold time Data after CLK0 0 ns
trec Recovery time, before CLKCLRor PRE2.7 2.4 ns
CD54AC74, CD74AC74
DUAL POSITIVE-EDGE-TRIGGERED D-TYPE FLIP-FLOPS
WITH CLEAR AND PRESET
SCHS231D SEPTEMBER 1998 REVISED DECEMBER 2002
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
VCC = 1.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER FROM
(INPUT)
TO
(OUTPUT)
55°C to
125°C40°C to
85°CUNIT
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
fmax 9 10 MHz
tPLH
CLK
QQ
125 114
ns
tPHL
CLK
Q
or
Q
125 114
ns
tPLH
PRE or CLR
QorQ
132 120
ns
tPHL
PRE
or
CLR
Q
or
Q
144 131
ns
switching characteristics over recommended operating free-air temperature range,
VCC = 3.3 V ±0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER FROM
(INPUT)
TO
(OUTPUT)
55°C to
125°C40°C to
85°CUNIT
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
fmax 79 90 MHz
tPLH
CLK
QQ
3.5 14 3.6 12.7
ns
tPHL
CLK
Q
or
Q
3.5 14 3.6 12.7
ns
tPLH
PRE or CLR
QorQ
3.7 14.7 3.8 13.4
ns
tPHL
PRE
or
CLR
Q
or
Q
4 16.1 4.1 14.6
ns
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ±0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER FROM
(INPUT)
TO
(OUTPUT)
55°C to
125°C40°C to
85°CUNIT
(INPUT)
(OUTPUT)
MIN MAX MIN MAX
fmax 110 125 MHz
tPLH
CLK
QQ
2.5 10 2.6 9.1
ns
tPHL
CLK
Q
or
Q
2.5 10 2.6 9.1
ns
tPLH
PRE or CLR
QorQ
2.6 10.5 2.7 9.5
ns
tPHL
PRE
or
CLR
Q
or
Q
2.9 11.5 3 10.4
ns
operating characteristics, TA = 25°C
PARAMETER TYP UNIT
Cpd Power dissipation capacitance 55 pF
CD54AC74, CD74AC74
DUAL POSITIVE-EDGE-TRIGGERED D-TYPE FLIP-FLOPS
WITH CLEAR AND PRESET
SCHS231D SEPTEMBER 1998 REVISED DECEMBER 2002
6POST OFFICE BOX 655303 DALLAS, TEXAS 75265
PARAMETER MEASUREMENT INFORMATION
VOLTAGE WAVEFORMS
SETUP AND HOLD AND INPUT RISE AND FALL TIMES
th
tsu
50% VCC
50% VCC
50% 10%10% 90% 90%
VCC
VCC
0 V
0 V
trtf
Reference
Input
Data
Input
VOLTAGE WAVEFORMS
PROPAGATION DELAY AND OUTPUT TRANSITION TIMES
50% VCC
50% VCC
50% 10%10% 90% 90%
VCC
VOH
VOL
0 V
trtf
Input
In-Phase
Output
50% VCC
tPLH tPHL
50% VCC 50%
10% 10% 90%90% VOH
VOL
tr
tf
tPHL tPLH
Out-of-Phase
Output
NOTES: A. CL includes probe and test-fixture capacitance.
B. W aveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
W aveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR 1 MHz, ZO = 50 , tr = 3 ns, tf = 3 ns.
Phase relationships between waveforms are arbitrary.
D. For clock inputs, fmax is measured with the input duty cycle at 50%.
E. The outputs are measured one at a time with one input transition per measurement.
F. tPLH and tPHL are the same as tpd.
G. tPZL and tPZH are the same as ten.
H. tPLZ and tPHZ are the same as tdis.
From Output
Under Test
CL = 50 pF
(see Note A)
LOAD CIRCUIT
S1 2 × VCC
R1 = 500Open
GND
0 V
tw
VOLTAGE WAVEFORMS
PULSE DURATION
Input 50% VCC
50% VCC
VCC
tPLH/tPHL
tPLZ/tPZL
tPHZ/tPZH
Open
2 × VCC
GND
TEST S1
Output
Control
Output
W aveform 1
S1 at 2 × VCC
(see Note B)
Output
W aveform 2
S1 at GND
(see Note B)
VOL
VOH
tPZL
tPZH
tPLZ
tPHZ
VCC
0 V
50% VCC 20% VCC
50% VCC 0 V
VOLTAGE WAVEFORMS
OUTPUT ENABLE AND DISABLE TIMES
50% VCC 50% VCC
80% VCC
VCC
R2 = 500
When VCC = 1.5 V, R1 = R2 = 1 k
VOLTAGE WAVEFORMS
RECOVER Y TIME
50% VCC VCC
0 V
CLR
Input
CLK 50% VCC VCC
trec
0 V
Figure 1. Load Circuit and Voltage Waveforms
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements,improvements, and other changes to its products and services at any time and to discontinue any product or service without notice.Customers should obtain the latest relevant information before placing orders and should verify that such information is current andcomplete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’sstandard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support thiswarranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarilyperformed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products andapplications using TI components. To minimize the risks associated with customer products and applications, customers shouldprovide adequate design and operating safeguards.TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, maskwork right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or servicesare used. Information published by TI regarding third-party products or services does not constitute a license from TI to use suchproducts or services or a warranty or endorsement thereof. Use of such information may require a license from a third party underthe patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI.Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and isaccompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is anunfair and deceptive business practice. TI is not responsible or liable for such altered documentation.Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or servicevoids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive businesspractice. TI is not responsible or liable for any such statements.TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product wouldreasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreementspecifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramificationsof their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-relatedrequirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding anyapplications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and itsrepresentatives against any damages arising out of the use of TI products in such safety-critical applications.TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products arespecifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet militaryspecifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade issolely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements inconnection with such use.TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI productsare designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use anynon-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements.Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products Applications
Amplifiers amplifier.ti.com Audio www.ti.com/audioData Converters dataconverter.ti.com Automotive www.ti.com/automotiveDSP dsp.ti.com Broadband www.ti.com/broadbandInterface interface.ti.com Digital Control www.ti.com/digitalcontrolLogic logic.ti.com Military www.ti.com/militaryPower Mgmt power.ti.com Optical Networking www.ti.com/opticalnetworkMicrocontrollers microcontroller.ti.com Security www.ti.com/securityLow Power www.ti.com/lpw Telephony www.ti.com/telephonyWireless
Video & Imaging www.ti.com/videoWireless www.ti.com/wireless
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265Copyright © 2007, Texas Instruments Incorporated
PACKAGING INFORMATION
Orderable Device Status (1) Package
Type Package
Drawing Pins Package
Qty Eco Plan (2) Lead/Ball Finish MSL Peak Temp (3)
CD54AC74F3A ACTIVE CDIP J 14 1 TBD A42 N / A for Pkg Type
CD74AC74E ACTIVE PDIP N 14 25 Pb-Free
(RoHS) CU NIPDAU N / A for Pkg Type
CD74AC74EE4 ACTIVE PDIP N 14 25 Pb-Free
(RoHS) CU NIPDAU N / A for Pkg Type
CD74AC74M ACTIVE SOIC D 14 50 Green (RoHS &
no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
CD74AC74M96 ACTIVE SOIC D 14 2500 Green (RoHS &
no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
CD74AC74M96E4 ACTIVE SOIC D 14 2500 Green (RoHS &
no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
CD74AC74M96G4 ACTIVE SOIC D 14 2500 Green (RoHS &
no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
CD74AC74ME4 ACTIVE SOIC D 14 50 Green (RoHS &
no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
CD74AC74MG4 ACTIVE SOIC D 14 50 Green (RoHS &
no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
(1) The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check
http://www.ti.com/productcontent for the latest availability information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and
package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS
compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)
(3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder
temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited
information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI
to Customer on an annual basis.
PACKAGE OPTION ADDENDUM
www.ti.com 15-Oct-2009
Addendum-Page 1
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device Package
Type Package
Drawing Pins SPQ Reel
Diameter
(mm)
Reel
Width
W1 (mm)
A0 (mm) B0 (mm) K0 (mm) P1
(mm) W
(mm) Pin1
Quadrant
CD74AC74M96 SOIC D 14 2500 330.0 16.4 6.5 9.0 2.1 8.0 16.0 Q1
PACKAGE MATERIALS INFORMATION
www.ti.com 11-Mar-2008
Pack Materials-Page 1
*All dimensions are nominal
Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm)
CD74AC74M96 SOIC D 14 2500 346.0 346.0 33.0
PACKAGE MATERIALS INFORMATION
www.ti.com 11-Mar-2008
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,and other changes to its products and services at any time and to discontinue any product or service without notice. Customers shouldobtain the latest relevant information before placing orders and should verify that such information is current and complete. All products aresold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standardwarranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except wheremandated by government requirements, testing of all parameters of each product is not necessarily performed.TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products andapplications using TI components. To minimize the risks associated with customer products and applications, customers should provideadequate design and operating safeguards.TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Informationpublished by TI regarding third-party products or services does not constitute a license from TI to use such products or services or awarranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectualproperty of the third party, or a license from TI under the patents or other intellectual property of TI.Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompaniedby all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptivebusiness practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additionalrestrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids allexpress and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is notresponsible or liable for any such statements.TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonablybe expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governingsuch use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, andacknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their productsand any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may beprovided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products insuch safety-critical applications.TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products arespecifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet militaryspecifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely atthe Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products aredesignated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designatedproducts in automotive applications, TI will not be responsible for any failure to meet such requirements.Following are URLs where you can obtain information on other Texas Instruments products and application solutions:Products ApplicationsAmplifiers amplifier.ti.com Audio www.ti.com/audioData Converters dataconverter.ti.com Automotive www.ti.com/automotiveDLP® Products www.dlp.com Broadband www.ti.com/broadbandDSP dsp.ti.com Digital Control www.ti.com/digitalcontrolClocks and Timers www.ti.com/clocks Medical www.ti.com/medicalInterface interface.ti.com Military www.ti.com/militaryLogic logic.ti.com Optical Networking www.ti.com/opticalnetworkPower Mgmt power.ti.com Security www.ti.com/securityMicrocontrollers microcontroller.ti.com Telephony www.ti.com/telephonyRFID www.ti-rfid.com Video & Imaging www.ti.com/videoRF/IF and ZigBee® Solutions www.ti.com/lprf Wireless www.ti.com/wireless
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265Copyright © 2009, Texas Instruments Incorporated