Thermal Overcurrent Circuit Breaker 1180-...
www.e-t-a.com06/07
1-
41
1
Current Internal Current Internal
rating (A) resistance () rating (A) resistance ()
0.1 81 2 0.25
0.2 22 2.5 0.18
0.25 14 3 0.11
0.3 8.7 3.5 0.08
0.4 5.5 4 0.07
0.5 3.4 5 0.05
0.6 2.5 6 0.05
0.7 1.7 7 0.05
0.8 1.5 8 0.05
1 0.9 10 0.05
1.5 0.4
Description
Typical applications
Ordering information
Approvals
Technical data
Miniaturised single pole thermal circuit breaker with switching function
optional (push-push actuation). Reliable snap-acting and trip-free
mechanism. Approved to CBE standard EN/IEC 60934. S-type, TO.
Blade terminals fitting into sockets for rail mounting.
Protection of loads in power distribution systems in control cabinets and
process control.
1180-...
Voltage rating AC 250 V; DC 65 V
(UL, UL Canada: AC 250 V; DC 72 V)
Current ratings 0.1...10 A
Typical life 6,000 operations at 1 x IN(low-inductance)
3,000 operations at 1 x IN(inductive)
500 operations at 2 x IN(inductive)
Ambient temperature -20...+60 °C (T 60) -4...+140 °F
Insulation co-ordination rated impulse pollution
(IEC 60664 and 60664 A) withstand voltage degree
2.5 kV 2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area AC 3,000 V
installation area AC 1,500 V
Insulation resistance > 100 M(DC 500 V)
Interrupting capacity Icn 0.1...5 A 6 x IN
6...10 A 8 x IN
Interrupting capacity AC 250 V: 2,000 A
(UL 1077) DC 65 V: 200 A
Degree of protection operating area IP40
(IEC 60529/DIN 40050) terminal area IP00
Vibration 5 g (57-500 Hz) ±0.38mm (10-57 Hz)
without terminal block to IEC 60068-2-6, test Fc,
10 frequency cycles/axis and to EN 50155
Shock 25 g (11 ms)
without terminal block to IEC 60068-2-27, test Ea
Corrosion 96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity 240 hours at 95 % RH
to IEC 60068-2-3, test Ca
Mass approx. 15 g
Authority Voltage rating Current ratings
VDE AC 250 V; DC 65 V 0.1...10 A
UL AC 250 V; DC 72 V 0.1...10 A
UL, Canada AC 250 V; DC 72 V 0.1...10 A
Standard current ratings and typical internal resistance values
Type No.
1180 single pole thermal circuit breaker, plug-in mounting
Versions
01 with switching function, without label
02 reset function only, without label
Current rating range
0.1...10 A
1180 - 01 - 1 A ordering example
www.e-t-a.com 06/07
1-
42
Thermal Overcurrent Circuit Breaker 1180-...
1
12468102040
Trip time in seconds
… times rated current
0.1 - 5 A
6 - 10 A
10000
1000
100
10
1
0.1
Dimensions Typical time/current characteristics at +23°C7+73.4°F
8.2
2.3°
.717
19,8
18.2
16.6
14.5
5.2
6.4
8.6
8.2
1.9
1.5
48.6 ON
48.8
52.3 OFF
24.4
1.1
3.6
3.1
0.6
.961
.323
.339
.252
.205
.780
.654
.571
.323
.122
.142
.075
.059
1.91
1.92
2.06
.043
.024
slot for fitting labels
(see accessory 1)
Note: When several devices are mounted together, each device should
only carry 80 % of its rating or it must be overrated accordingly.
The time/current characteristic curve depends on the ambient temperature
prevailing. In order to eliminate nuisance tripping, please multiply the circuit
breaker current ratings by the derating factor shown below. See also
section 9 – Technical information.
Ambient temperature °F -22 -4 +14 +32 +73.4 +104 +122 +140
°C -30 -20 -10 0 +23 +40 +50 +60
Derating factor 0.8 0.76 0.84 0.92 1 1.08 1.16 1.24
This is a metric design and millimeter dimensions take precedence ( mm )
inch
Internal connection diagram
1
2
Shock directions
1
2
4
3
6
5
current rating
1.0
A
label
Y 307 374 01
Thermal Overcurrent Circuit Breaker 1180-...
www.e-t-a.com06/07
1-
43
1
Accessories - Terminal block with screw terminals
8
42.7
33.8
36.4
64.3
Dimensions X 222 233 02
LED
1.33
1.43
1.68
2.53
.315
1
2
5
4
3
6
1Label for circuit breaker 1180, surface for marking 4.5 x 5 mm
(packaging quantity 120 pcs)
Y 307 374 01
2Terminal block for DIN rail mounting, with screw terminals
up to 6 mm2conductor, width 8.2 mm,
dimensions 64 x 42.5 x 8.2 mm,
headroom over the upper rail edge with circuit breaker fitted
(OFF position) 84 mm.
Approvals: UL 300 V / 30 A / AWG 26-8
X 222 233 01
3Terminal block for DIN rail mounting see item 2,
but with LED DC 24 V (lighted after tripping);
current rating LED 2 mA
X 222 233 02
4Bus connection for potential bridging of several terminal blocks
see item 2 and 3 (10-pole, separable, mounting hardware
included), max. current rating 34 A
X 222 232 01
5Insulation barriers for insertion between two circuits
(packaging quantity 10 pcs)
Y 307 373 01
6Label for terminal block, see item 2 and 3,
surface for marking 8 x 10 mm
(packaging quantity 10 pcs)
Y 307 375 01
Vibration with terminal block X 222 233 01
and X 222 233 02
5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
and EN 50155
Shock with terminal block X 222 233 01
and X 222 233 02
25 g (11 ms)
to IEC 60068-2-27, test Ea
This is a metric design and millimeter dimensions take precedence ( mm )
inch
This is a metric design and millimeter dimensions take precedence ( mm )
inch
www.e-t-a.com 06/07
1-
44
Thermal Overcurrent Circuit Breaker 1180-...
1
1
9
13
7
8
11
12
Accessories - Terminal block with spring-loaded terminals
42.2
8.2
86.5
Dimensions X 222 316 01
1.66
.323
3.41
1Label for circuit breaker 1180, surface for marking 4.5 x 5 mm
(packaging quantity 120 pcs)
Y 307 374 01
7Terminal block for DIN rail mounting, with spring-loaded
terminals up to 4 mm2conductor, width 8.2 mm, dimensions
68.5 x 36.5 x 8.2 mm, headroom over the upper rail edge
with circuit breaker fitted (OFF position) 82 mm.
UL approval pending.
X 222 316 01
8Terminal block for DIN rail mounting see item 7, but with
LED DC 24 V (lighted after tripping); current rating LED 2 mA
X 222 315 02
9Jumper 2pole, max. current rating 32 A for terminal blocks
items 7 and 8 and feed supply terminal item 11.
X 222 318 01
10 Jumper 3pole, max. current rating 32 A for terminal blocks
items 7 and 8 and feed supply terminal item 11.
X 222 318 02
11 Feed supply terminal with spring-loaded terminals
up to 6 mm2 conductor, width 8.2 mm, suitable for use with
jumpers items 9 and 10 (power distribution).
X 222 317 01
12 Cover for feed supply terminal item 11 for closing the open
side at the end of an assembly.
Y 307 507 01
13 Label for terminal block items 7 and 8,
and feed supply terminal item 11,
surface for marking 7.5 x 5 mm
(packaging quantity 50 pcs)
Y 307 508 01
Vibration with terminal blocks X 222 316 01
and X 222 315 02
vibration axis 3-4:
3 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
other axes:
5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
and EN 50155
Shock with terminal blocks X 222 316 01
and X 222 315 02
25 g (11 ms)
to IEC 60068-2-27, test Ea
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.