–1– ASCTB23E 201806-T
ORDERING INFORMATION
TYPES
Standard packing: Carton 20 pcs., Case 500 pcs.
Slim type SSR for
1 A and 2 A control
AQ-G RELAYS
Type Load current Load voltage Control voltage Part No.
Zero-cross
1 A 75 to 264 Vrms
4 to 6 V DC AQG12105
9.6 to 14.4 V DC AQG12112
19.2 to 28.8 V DC AQG12124
2 A 75 to 264 Vrms
4 to 6 V DC AQG22105
9.6 to 14.4 V DC AQG22112
19.2 to 28.8 V DC AQG22124
Random
1 A 75 to 264 Vrms
4 to 6 V DC AQG12205
9.6 to 14.4 V DC AQG12212
19.2 to 28.8 V DC AQG12224
2 A 75 to 264 Vrms
4 to 6 V DC AQG22205
9.6 to 14.4 V DC AQG22212
19.2 to 28.8 V DC AQG22224
VDE
RoHS compliant
FEATURES
1. Space saving, Vertical size with a
maximum thickness of 4.5 mm.
Mounting space has been reduced to
30% (compared to conventional SSR’s)
while meeting high density PC board
mounting requirements.
2. Snubber circuit preventing
malfunction
3. Zero-cross type and Random type
available
4. High dielectric strength of 3,000
Vrms
(between input and output)
5. Snubber circuit integrated
The snubber circuit is integrated to
prevent malfunction caused by the rapid
rise of voltage on the output side, such as
inductive load and current.
TYPICAL APPLICATIONS
Household appliances such as air
conditioners, refrigerators and
humidifiers
Healthcare and medical equipment
Industrial machinery such as NC
machines, mounters, injection
molders, and robots
Microcomputer boards
Amusement and amenity related
equipment
Load current
1: 1 A
2: 2 A
AQG
Load voltage
2: 75 to 264 Vrms
Type
1: Zero-cross (3,000 V)
2: Random (3,000 V)
Control voltage
05: 4 to 6 V DC
12: 9.6 to 14.4 V DC
24: 19.2 to 28.8 V DC
AQ-G
–2– ASCTB23E 201806-T
RATING
1. Ratings (Ambient temperature: 20°C 68°F, Input voltage ripple: 1% or less)
1) Zero-cross type
2) Random type
Notes: *1. Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
*2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of Solid State Relays”.
2. Characteristics (Ambient temperature: 20°C 68°F, Input voltage ripple: 1% or less)
Item Type Part No. Remarks
AQG12105 AQG12112 AQG12124 AQG22105 AQG22112 AQG22124
Input
side
Rated voltage 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC
*1
Control voltage 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC
Input impedance Approx. 0.3 kΩApprox. 0.8 kΩApprox. 1.6 kΩApprox. 0.3 kΩApprox. 0.8 kΩApprox. 1.6 kΩ
Drop-out
voltage, min. 1 V
Reverse voltage 3 V
Load
side
Max. load current 1 A*22 A*2
1 A:
Ta = Max. 40°C 104°F
2 A:
Ta = Max. 25°C 77°F
Load voltage 75 to 264 Vrms
Frequency 45 to 65 Hz
Non-repetitive
surge current 8 A*330 A*3In one cycle at 60 Hz
Max. “OFF-state”
leakage current 1.5 mA at 60 Hz at 200 Vrms
Max. “ON-state”
voltage drop 1.6 V at Max. carrying
current
Min. load current 20 mA*4
Item Type Part No. Remarks
AQG12205 AQG12212 AQG12224 AQG22205 AQG22212 AQG22224
Input
side
Rated voltage 5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC
*1
Input voltage 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC
Input impedance Approx. 0.3 kΩApprox. 0.8 kΩApprox. 1.6 kΩApprox. 0.3 kΩApprox. 0.8 kΩApprox. 1.6 kΩ
Drop-out
voltage, min. 1 V
Reverse voltage 3 V
Load
side
Max. load current 1 A*22 A*2
1 A:
Ta = Max. 40°C 104°F
2 A:
Ta = Max. 25°C 77°F
Load voltage 75 to 264 Vrms
Frequency 45 to 65 Hz
Non-repetitive
surge current 8 A*330 A*3In one cycle at 60 Hz
Max. “OFF-state”
leakage current 1.5 mA at 60 Hz at 200 Vrms
Max. “ON-state”
voltage drop 1.6 V at Max. carrying
current
Min. load current 20 mA*4
Item Zero-cross type Random type Remarks
Operate time max. 1/2 cycle of voltage sine wave +1 ms 1 ms
Release time, max. 1/2 cycle of voltage sine wave +1 ms
Insulation resistance, min. 109 Ω between input and output at 500 V DC
Breakdown voltage 3,000 Vrms between input and output for 1 minute
Vibration resistance 10 to 55 Hz double amplitude of 0.75 mm X, Y, Z axes
Shock resistance Min. 1,000 m/s2X, Y, Z axes
Ambient temperature –30 to +80°C –22 to +176°FNon-condensing at low
temperatures
Storage temperature –30 to +100°C –22 to +212°FNon-condensing at low
temperatures
Operational method Zero-cross (Turn-ON and Turn-OFF) Random turn ON, zero-cross turn OFF
AQ-G
–3– ASCTB23E 201806-T
REFERENCE DATA
DIMENSIONS (mm inch)
1. Load current vs. ambient temperature
2.-(1) Non-repetitive surge current vs. carrying time
(1 A type)*
2.-(2) Non-repetitive surge current vs. carrying time
(2 A type)*
0.5
1.0
1.5
2.0
2.5
00-30 20 40 60 80 100
Ambient temperature, °C
Load current, A
1 A type
2 A type
0
4
2
10
8
6
1 10 100
No. of cycles at 60 Hz
Non-repetitive surge current, A
0
10
5
40
30
35
25
15
20
1 10 100
No. of cycles at 60 Hz
Non-repetitive surge current, A
Note: * The above chart shows non-repetitive maximum rating. If a surge current is applied repeatedly, please keep it approximately 50% or less than the values shown in
the above graph.
3. Input current vs. input voltage characteristics 4.-(1) Load current vs. ambient temperature
characteristics for adjacent mounting
(1 A type)
4.-(2) Load current vs. ambient temperature
characteristics for adjacent mounting
(2 A type)
5
10
15
20
25
30
10 155020253530
Input voltage, V
Input current, mA
(5 V type) (12 V type) (24 V type)
1.0
1.2
0.8
0.6
0.2
0.4
0200-30 40 60 80 100
Ambient temperature, °C
=15 mm
.591 inch
=10 mm
.394 inch
=5 mm
.197 inch
= Adjacent mounting pitch
Load current, A
2.0
2.5
1.5
1.0
0.5
0200-30 40 60 80 100
Ambient temperature, °C
=15 mm
=10 mm
=5 mm
.591 inch
.394 inch
.197 inch
= Adjacent mounting pitch
Load current, A
mark can be downloaded from: https://industrial.panasonic.com/ac/e/The CAD data of the products with a
1. 1 A type External dimensions
General tolerance: ±0.2 ±.008
24.5 max.
4-0.7
4-1.6
2.54 10.16 7.62
1.2
0.25
4.5 max.
13.5 max.
0.8
3.7
.965 max.
4-.028
4-.063
.100 .400 .300
.047
.010
.177 max.
.531 max.
.031
.146
PC board pattern (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
2.54 10.16 7.62
4-1.0 dia.
1.2
.100 .400 .300
4-.039 dia.
.047
OutputInput
+
2. 2 A type External dimensions
General tolerance: ±0.2 ±.008
24.5 max.
7.6210.162.54
4-1.6
4-0.7
4.5 max.
0.25
1.2
20.5 max.
0.8
3.7
.965 max.
.300.400.100
4-.063
4-.028
.177 max.
.010
.047
.807 max.
.031
.146
PC board pattern (Bottom view)
Tolerance: ±0.1 ±.004
Schematic
2.54 10.16 7.62
4-1.0 dia.
1.2
.100 .400 .300
4-.039 dia.
.047
OutputInput
+
AQ-G
–4– ASCTB23E 201806-T
SCHEMATIC AND WIRING DIAGRAMS
Recommended Temperature Controllers
Schematic
Output
configura-
tion
Load Wiring diagram
1 Form A AC
2
1
4
3
Zero-cross circuit
ZC
Input circuit
+
Load power
supply
Operation
power
Load
LOADINPUT
34 2 1
2
1
4
3
Input circuit
+
48 mm
56 mm
1.890 inch
2.205 inch
48 mm
1.890 inch
<KT4H Temperature Controller>
Our temperature controller is recommended for use with our Solid State Relays.
Features
• Space saving requiring only a depth of 65 mm
• Data collection possible through a PLC using RS485 communication
Tool port is standard for easy data setting
• Inverted LCD + backlight for good legibility with large characters
• Excellent operability and rich optional control functions
Substitute part numbers
* For detailed product information about temperature controllers, please refer to our website:
https://industrial.panasonic.com/ac/e/
Power supply Control output Part No.
100 to 240 Vrms Non-contact voltage output AKT4H112100