VDE Slim type SSR for 1 A and 2 A control RoHS compliant AQ-G RELAYS FEATURES TYPICAL APPLICATIONS 1. Space saving, Vertical size with a maximum thickness of 4.5 mm. Mounting space has been reduced to 30% (compared to conventional SSR's) while meeting high density PC board mounting requirements. 2. Snubber circuit preventing malfunction 3. Zero-cross type and Random type available 4. High dielectric strength of 3,000 Vrms (between input and output) 5. Snubber circuit integrated The snubber circuit is integrated to prevent malfunction caused by the rapid rise of voltage on the output side, such as inductive load and current. * Household appliances such as air conditioners, refrigerators and humidifiers * Healthcare and medical equipment * Industrial machinery such as NC machines, mounters, injection molders, and robots * Microcomputer boards * Amusement and amenity related equipment ORDERING INFORMATION AQG Load current 1: 1 A 2: 2 A Load voltage 2: 75 to 264 Vrms Type 1: Zero-cross (3,000 V) 2: Random (3,000 V) Control voltage 05: 4 to 6 V DC 12: 9.6 to 14.4 V DC 24: 19.2 to 28.8 V DC TYPES Type Load current Load voltage 1A 75 to 264 Vrms 2A 75 to 264 Vrms 1A 75 to 264 Vrms 2A 75 to 264 Vrms Control voltage 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC Zero-cross Random Part No. AQG12105 AQG12112 AQG12124 AQG22105 AQG22112 AQG22124 AQG12205 AQG12212 AQG12224 AQG22205 AQG22212 AQG22224 Standard packing: Carton 20 pcs., Case 500 pcs. -1- ASCTB23E 201806-T AQ-G RATING 1. Ratings (Ambient temperature: 20C 68F, Input voltage ripple: 1% or less) 1) Zero-cross type Item Input side Type Rated voltage Control voltage Input impedance Drop-out voltage, min. Reverse voltage AQG12105 5 V DC 4 to 6 V DC Approx. 0.3 k Part No. AQG12124 AQG22105 24 V DC 5 V DC 19.2 to 28.8 V DC 4 to 6 V DC Approx. 1.6 k Approx. 0.3 k AQG22112 12 V DC 9.6 to 14.4 V DC Approx. 0.8 k AQG22124 24 V DC 19.2 to 28.8 V DC Approx. 1.6 k *1 Remarks 1V 3V Max. load current Load side AQG12112 12 V DC 9.6 to 14.4 V DC Approx. 0.8 k 1 A*2 Load voltage Frequency Non-repetitive surge current Max. "OFF-state" leakage current Max. "ON-state" voltage drop 2 A*2 1 A: Ta = Max. 40C 104F 2 A: Ta = Max. 25C 77F 30 A*3 In one cycle at 60 Hz 75 to 264 Vrms 45 to 65 Hz 8 A*3 1.5 mA at 60 Hz at 200 Vrms at Max. carrying current 1.6 V Min. load current 20 mA*4 2) Random type Item Input side Type Rated voltage Input voltage Input impedance Drop-out voltage, min. Reverse voltage Max. load current Load side Load voltage Frequency Non-repetitive surge current Max. "OFF-state" leakage current Max. "ON-state" voltage drop AQG12205 5 V DC 4 to 6 V DC Approx. 0.3 k AQG12212 12 V DC 9.6 to 14.4 V DC Approx. 0.8 k Part No. AQG12224 AQG22205 24 V DC 5 V DC 19.2 to 28.8 V DC 4 to 6 V DC Approx. 1.6 k Approx. 0.3 k AQG22224 24 V DC 19.2 to 28.8 V DC Approx. 1.6 k *1 Remarks 1V 3V 1 A*2 2 A*2 1 A: Ta = Max. 40C 104F 2 A: Ta = Max. 25C 77F 30 A*3 In one cycle at 60 Hz 75 to 264 Vrms 45 to 65 Hz 8 A*3 1.5 mA at 60 Hz at 200 Vrms at Max. carrying current 1.6 V Min. load current Notes: *1. *2. *3. *4. AQG22212 12 V DC 9.6 to 14.4 V DC Approx. 0.8 k 20 mA*4 Refer to REFERENCE DATA "3. Input current vs. input voltage characteristics". Refer to REFERENCE DATA "1. Load current vs. ambient temperature". Refer to REFERENCE DATA "2. Non-repetitive surge current vs. carrying time". When the load current is less than the rated minimum load current, please refer to "Cautions for Use of Solid State Relays". 2. Characteristics (Ambient temperature: 20C 68F, Input voltage ripple: 1% or less) Item Operate time max. Release time, max. Insulation resistance, min. Breakdown voltage Vibration resistance Shock resistance Ambient temperature Storage temperature Operational method Zero-cross type Random type 1/2 cycle of voltage sine wave +1 ms 1 ms 1/2 cycle of voltage sine wave +1 ms 109 between input and output 3,000 Vrms between input and output 10 to 55 Hz double amplitude of 0.75 mm Min. 1,000 m/s2 -30 to +80C -22 to +176F -30 to +100C -22 to +212F Zero-cross (Turn-ON and Turn-OFF) Remarks at 500 V DC for 1 minute X, Y, Z axes X, Y, Z axes Non-condensing at low temperatures Non-condensing at low temperatures Random turn ON, zero-cross turn OFF -2- ASCTB23E 201806-T AQ-G REFERENCE DATA 2.-(1) Non-repetitive surge current vs. carrying time (1 A type)* 1. Load current vs. ambient temperature 10 2 A type 1.5 1 A type 1.0 0.5 40 Non-repetitive surge current, A 2.0 Non-repetitive surge current, A 2.5 Load current, A 2.-(2) Non-repetitive surge current vs. carrying time (2 A type)* 8 6 4 2 35 30 25 20 15 10 5 0 -30 0 20 40 60 80 Ambient temperature, C 0 100 1 10 No. of cycles at 60 Hz 0 100 1 10 No. of cycles at 60 Hz 100 Note: * The above chart shows non-repetitive maximum rating. If a surge current is applied repeatedly, please keep it approximately 50% or less than the values shown in the above graph. 3. Input current vs. input voltage characteristics 4.-(1) Load current vs. ambient temperature characteristics for adjacent mounting (1 A type) 1.2 2.5 =15 mm .591 inch =10 mm .394 inch 1.0 20 (5 V type) (12 V type) Load current, A 25 (24 V type) 15 0.8 0.4 5 0.2 0 5 10 15 20 25 30 Input voltage, V =5 mm .197 inch 0.6 10 DIMENSIONS (mm inch) = Adjacent mounting pitch 0 20 40 60 80 Ambient temperature, C The CAD data of the products with a 1. 1 A type 2.0 =15 mm .591 inch 1.5 =10 mm .394 inch =5 mm .197 inch 1.0 0.5 0 -30 35 Load current, A 30 Input current, mA 4.-(2) Load current vs. ambient temperature characteristics for adjacent mounting (2 A type) 100 = Adjacent mounting pitch 0 20 40 60 80 Ambient temperature, C 100 mark can be downloaded from: https://industrial.panasonic.com/ac/e/ External dimensions PC board pattern (Bottom view) 4.5 max. .177 max. 24.5 max. .965 max. 0 -30 2.54 .100 10.16 .400 0.8 13.5 max. .031 .531 max. 7.62 .300 1.2 .047 4-1.0 dia. 4-.039 dia. Tolerance: 0.1 .004 4-1.6 4-.063 2.54 .100 4-0.7 4-.028 10.16 .400 1.2 .047 7.62 .300 3.7 .146 0.25 .010 Schematic Input - + Output General tolerance: 0.2 .008 2. 2 A type External dimensions PC board pattern (Bottom view) 4.5 max. .177 max. 24.5 max. .965 max. 2.54 .100 10.16 .400 7.62 .300 1.2 .047 4-1.0 dia. 4-.039 dia. 20.5 max. 0.8 .807 max. .031 Tolerance: 0.1 .004 Schematic 4-1.6 4-.063 2.54 .100 1.2 .047 4-0.7 4-.028 10.16 .400 7.62 .300 3.7 .146 0.25 .010 Input - + Output General tolerance: 0.2 .008 -3- ASCTB23E 201806-T AQ-G SCHEMATIC AND WIRING DIAGRAMS Output configuration Schematic Load Wiring diagram + 3 1 Input circuit 4 ZC - 2 INPUT 4 3 Zero-cross circuit 1 Form A LOAD 2 1 AC + 3 1 Load Operation power Input circuit 4 Load power supply 2 - Recommended Temperature Controllers <KT4H Temperature Controller> Our temperature controller is recommended for use with our Solid State Relays. 48 mm 1.890 inch 56 mm 2.205 inch Features * Space saving requiring only a depth of 65 mm * Data collection possible through a PLC using RS485 communication * Tool port is standard for easy data setting * Inverted LCD + backlight for good legibility with large characters * Excellent operability and rich optional control functions Substitute part numbers 48 mm 1.890 inch Power supply 100 to 240 Vrms Control output Non-contact voltage output Part No. AKT4H112100 * For detailed product information about temperature controllers, please refer to our website: https://industrial.panasonic.com/ac/e/ -4- ASCTB23E 201806-T