2 FORM C—200 mW
SENSITIVE MINIATURE RELAY
1500 V FCC SURGE
WITHSTAND
160 µs
10 µs
1500V
750V
Initial insulation resistance*1
Operate time*3 (at nominal voltage) Approx. 4 ms
Initial
breakdown
voltage*2
Between open contacts
Between contact sets
Between contact and coil
750 Vrms
1,000 Vrms
1,000 Vrms
Min. 1,000 M (at 500 V DC)
Shock resistance
Vibration
resistance
Unit weight
Remarks
*1 Measurement at same location as “Initial breakdown voltage” section
*2 Detection current: 10mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms, detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
*7 Refer to 5. Conditions for operation, transport and storage mentioned in
*7 AMBIENT ENVIRONMENT (Page 49)
Approx. 4 g .14 oz
Min. 490 m/s2 {50 G}
Min. 980 m/s2 {100 G}
Functional*4
Destructive*5
Functional*6
Destructive
196 m/s2 {20 G}, 10 to 55 Hz
at double amplitude of 3.3 mm
294 m/s2 {30 G}, 10 to 55 Hz
at double amplitude of 5 mm
Conditions for operation,
transport and storage*7
(Not freezing and condensing
at low temperature)
Ambient temp.
Humidity
–40°C to +70°C
–40°F to +158°F
5 to 85% R.H.
Release time (without diode)*3
(at nominal voltage) Approx. 3 ms
1,500 V
Max. 65°C with nominal voltage acloss
coil and at nominal switching capacity
Set time*3 (latching)
(at nominal voltage)
Approx. 3 ms
Reset time*3 (latching)
(at nominal voltage)
Approx. 3 ms
Temperature rise
FCC surge voltage between
contacts and coil
Contact
Arrangement 2 Form C
Contact material
UL/CSA rating
Expected
life (min.
operations)
Gold-clad sliver
Rating
(resistive)
60 W, 62.5 VA
220 V DC, 250V AC
2 A
3 A
0.3 A 125 V AC
0.3 A 110 V DC
1 A 30 V DC
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) 50 m
Coil (polarized) (at 20°C 68°F)Approx. 98 mW
(147 mW: 48 V)
Single side
stable
Minimum operating power
1 × 108
5 × 105
1 × 105
Approx. 200 mW
(300 mW: 48 V)
Nominal operating power
Approx. 88 mW
(177 mW: 48 V)
2 coil
latching
Minimum set and reset power
Approx. 180 mW
(360 mW: 48 V)
Nominal set and reset power
FCC (Federal Communication Commission) requests following standard as
Breakdown Voltage specification.
Max. switching power
Max. switching voltage
Max. switching current
Max. carrying current
Mechanical
Electrical 1 A 30 V DC
2 A 30 V DC
DS2Y-
RELAYS
mm inch
UL File No.: E43149
CSA File No.: LR26550
SPECIFICATIONS
TYPICAL APPLICATIONS ORDERING INFORMATION
• Telecommunication equipment
• Office equipment
• Computer peripherals
• Security / alarm systems
• Medical equipment
• 2 Form C contact
• High sensitivity: 200 mW nominal operating power
• High breakdown voltage
1500 V FCC surge between open contacts
• DIP: 2C type matching 16 pin IC socket
• Sealed construction
DC12 V
Operating function
L2Ex DS2Y-S R
Nil: Single side stable
L2: 2 coil latching
(Note) Standard packing: Carton: 50 pcs. Case: 500 pcs.
Coil voltage
DC 1.5, 3, 5, 6,
9, 12, 24, 48 V
Polarity
Nil: Standard polarity
R: Reverse polarity
20
.787
9.3
.366
9.9
.390
TYPES AND COIL DATA at 20°C 68°F
DIMENSIONS
Single side stable
General tolerance: ±0.3 ±.012
mm inch
Single side stable
Nominal
voltage,
V DC
Drop-out
voltage, V
DC (min.)
Nominal
operating
current mA
(±10%)
Coil
resistance,
(±10%)
Nominal
operating
power mW
Maximum
allowable
voltage, V DC
(at 50°C 122°F)
Pick-up
voltage, V
DC (max.)
Part No.
1.5 DS2Y-S-DC1.5V 1.05 0.15 132.7 000011.3 200 03
3.0 DS2Y-S-DC3V 2.10 0.30066.7 000045.0 200 06
5.0 DS2Y-S-DC5V 3.500.5040.0,125 200 10
6.0 DS2Y-S-DC6V 4.200.60033.3 0,180 200 12
9.0 DS2Y-S-DC9V 6.300.90022.2 0,405 200 18
12.00 DS2Y-S-DC12V 8.401.20016.7 .0720 200 24
24.00 DS2Y-S-DC24V 16.800 2.40008.3 2,880 200 48
48.00 DS2Y-S-DC48V 33.600 4.80006.3 7,680 300 86
2 coil latching
Nominal
voltage,
V DC
Nominal operating
current mA (±10%) Coil resistance,
(±10%) Nominal operating
power mW Maximum
allowable
voltage, V DC
(at 50°C 122°F)
Reset set,
V DC (max.)
Part No.
1.5 DS2Y-SL2-DC1.5V 1.05 120 00,0.12.5 180 03
3.0 DS2Y-SL2-DC3V 2.10060 0,050 180 06
5.0 DS2Y-SL2-DC5V 3.50036 0,139 180 10
6.0 DS2Y-SL2-DC6V 4.20030 0,200 180 12
9.0 DS2Y-SL2-DC9V 6.30020 0,450 180 18
12.00 DS2Y-SL2-DC12V 8.40015 0,800 180 24
24.00 DS2Y-SL2-DC24V 16.800 0007.5 3,200 180 48
48.00 DS2Y-SL2-DC48V 33.600 0007.5 6,400 360 72
Set Reset Set Reset Set Reset
5.08
.200 5.08
.200
9.3
.366
20
.787
7.62
.300
0.6
.024
2.0
.078
0.6
.024
0.6
.024
3.4
.134
0.3
.012
5.6
.220
7.62
.300
9.9
.390 2.54
.100
2.54
.100
8-0.9 dia
8-.035 dia
7.62
.300
matching 16 pin IC socket
*A polarity bar shows the relay direction.
(Deenergized position)
N.O.
8
Direction indication*
9
N.O. 13
COM 16
N.C.
6COM
4
11
N.C.
+
1
PC board pattern (Copper-side view)
Tolerance: ±0.1 ±.004 Schematic (Bottom view)2 coil latching
General tolerance: ±0.3 ±.012
5.08
.200 5.08
.200
9.3
.366
20
.787
0.6
.024
2.0
.078
0.6
.024
0.6
.024
3.4
.134
0.3
.012
5.6
.220
7.62
.300
9.9
.390
5.08
.200 2.54
.100
2.54
.100
2.54
.100
10-0.9 dia
10-.035 dia
7.62
.300
matching 16 pin IC socket
*A polarity bar shows the relay direction.
(Reset position)
SET
8
Direction indication*
9
SET 13
COM 15
RST
6COM
4
11
RST
+
2
16
+
1
Set
Reset
Diagram shows the “reset” posetion when
terminals 2 and 15 are energized. Energize
terminals 1 and 16 to transfer contacts.
PC board pattern (Copper-side view)
Tolerance: ±0.1 ±.004 Schematic (Bottom view)
Switching current
Contact voltage
1,000 V
100 V
10 V
10 mA
10 µA 100 mA 1 A
2.-(1) Coil temperature rise (Single side stable)
Ambient temperature: 21°C to 25°C 70°F to 77°F
Sample: DS2Y-S-DC12V, 5 pcs.
(Inside of coil)
Coil applied voltage, %V
Temperature rise, °C
30
100 110
3 A
2 A
0 A
20
2.-(2) Coil temperature rise (2 coil latching)
Ambient temperature: 21°C to 25°C 70°F to 77°F
Sample: DS2Y-SL2-DC12V, 5 pcs.
(Inside of coil)
Coil applied voltage, %V
Set coil
Reset coil
Temperature rise, °C
30
1000 110
0 A
2 A
3 A
20
DS2Y
REFERENCE DATA
1. Maximum switching power
Coil applied voltage, %V
Mean value
Mean value
Time, ms
5
4
3
2
1
800 100 120
Operate time
Release time
4. Influence of adjacent mounting
Ambient temperature: 20°C 68°F
Sample: DS2Y-S-DC12V 10 pcs.
TEST METHOD
(1) Apply nominal voltage to No. (1) and (3) DS2Y
relays.
(2) Measure pick-up voltage and drop-out
voltage of No. (2) relay when inter-relay
distance (R) changes.
Inter-relay distance, mm inch
Pick-up/Drop-out voltage, V
10
8
6
4
2
05
.197 10
.394 15
.591
Pick-up voltage
Drop-out voltage
(1)
OFF (2) (3)
OFF
ON ON
OFF OFF
ON ON
R R
Inter-relay distance, mm inch
Pick-up/Drop-out voltage, V
10
8
6
4
2
05
.197 10
.394 15
.591
Pick-up voltage
Drop-out voltage
(1)
OFF (2) (3)
OFF
ON ON
OFF OFF
ON ON
R R
3. Operate/release time (single side stable)
Ambient temperature: 20°C 68°F
Sample: DS2Y-S-DC12V, 10 pcs.
(Without diode)
For Cautions for Use
Go To Online Catalog
6/1/1999 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.