160 µs
10 µs
1500V
750V
Initial insulation resistance*1
Operate time*3 (at nominal voltage) Approx. 4 ms
Initial
breakdown
voltage*2
Between open contacts
Between contact sets
Between contact and coil
750 Vrms
1,000 Vrms
1,000 Vrms
Min. 1,000 MΩ (at 500 V DC)
Shock resistance
Vibration
resistance
Unit weight
Remarks
*1 Measurement at same location as “Initial breakdown voltage” section
*2 Detection current: 10mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms, detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
*7 Refer to 5. Conditions for operation, transport and storage mentioned in
*7 AMBIENT ENVIRONMENT (Page 49)
Approx. 4 g .14 oz
Min. 490 m/s2 {50 G}
Min. 980 m/s2 {100 G}
Functional*4
Destructive*5
Functional*6
Destructive
196 m/s2 {20 G}, 10 to 55 Hz
at double amplitude of 3.3 mm
294 m/s2 {30 G}, 10 to 55 Hz
at double amplitude of 5 mm
Conditions for operation,
transport and storage*7
(Not freezing and condensing
at low temperature)
Ambient temp.
Humidity
–40°C to +70°C
–40°F to +158°F
5 to 85% R.H.
Release time (without diode)*3
(at nominal voltage) Approx. 3 ms
1,500 V
Max. 65°C with nominal voltage acloss
coil and at nominal switching capacity
Set time*3 (latching)
(at nominal voltage)
Approx. 3 ms
Reset time*3 (latching)
(at nominal voltage)
Approx. 3 ms
Temperature rise
FCC surge voltage between
contacts and coil
Contact
Arrangement 2 Form C
Contact material
UL/CSA rating
Expected
life (min.
operations)
Gold-clad sliver
Rating
(resistive)
60 W, 62.5 VA
220 V DC, 250V AC
2 A
3 A
0.3 A 125 V AC
0.3 A 110 V DC
1 A 30 V DC
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) 50 mΩ
Coil (polarized) (at 20°C 68°F)Approx. 98 mW
(147 mW: 48 V)
Single side
stable
Minimum operating power
1 × 108
5 × 105
1 × 105
Approx. 200 mW
(300 mW: 48 V)
Nominal operating power
Approx. 88 mW
(177 mW: 48 V)
2 coil
latching
Minimum set and reset power
Approx. 180 mW
(360 mW: 48 V)
Nominal set and reset power
FCC (Federal Communication Commission) requests following standard as
Breakdown Voltage specification.
Max. switching power
Max. switching voltage
Max. switching current
Max. carrying current
Mechanical
Electrical 1 A 30 V DC
2 A 30 V DC
DS2Y-
RELAYS
mm inch
UL File No.: E43149
CSA File No.: LR26550
SPECIFICATIONS
TYPICAL APPLICATIONS ORDERING INFORMATION
• Telecommunication equipment
• Office equipment
• Computer peripherals
• Security / alarm systems
• Medical equipment
• 2 Form C contact
• High sensitivity: 200 mW nominal operating power
• High breakdown voltage
1500 V FCC surge between open contacts
• DIP: 2C type matching 16 pin IC socket