1N5333B thru 1N5388B
Zener Diode, 5 Watt
5% Tolerance
Features:
DZener Voltage: 3.3V to 200V
DHigh Surge Current Capability
Absolute Maximum Ratings:
DC Power Dissipation (TL = +75C, Lead Length = 3/8”), PD5W.............................
Derate Above 75C 40mW/C......................................................
Forward Voltage (IF = 1A), VF1.2V.......................................................
Operating Junction Temperature Range, TJ65 to +200C..................................
Storage Temperature Range, Tstg 65 to +200C..........................................
Electrical Characteristics: (TA = +25C unless otherwise specified)
Device
Number
Nominal
Zener
Voltage
VZ @ IZT
(Note 1)
Test
Current
IZT
Max Zener Impedance
Max Reverse
Leakage Current Max Surge
Current
ir
(Note 2)
Max
Voltage
Regulation
VZ
(Note 3)
Max
Regulator
Current
IZM
ZZT @ IZT
(Note 1)
ZZK @ IZK = 1mA
(Note 1) IR@V
R
Volts mA AVolts Amps Volt mA
1N5333B 3.3 380 3.0 400 300 120 0.85 1440
1N5334B 3.6 350 2.5 500 150 118.7 0.8 1320
1N5335B 3.9 320 2500 50 117.6 0.54 1220
1N5336B 4.3 290 2500 10 116.4 0.49 1100
1N5337B 4.7 260 2450 5 1 15.3 0.44 1010
1N5338B 5.1 240 1.5 400 1 1 14.4 0.39 930
1N5339B 5.6 220 1400 1 2 13.4 0.25 865
Note 1 Test conditions for zener voltage and impedance are as follows: IZ is applied 40 10ms prior
to reading. Mounting contacts are located 3/8” to 1/2” from the inside edge of mounting clips
to the body of the diode (TA = +25C +8, 2C).
Note 2 Surge current is specified as the maximum allowable peak, nonrecurrent squarewave cur-
rent with a pulse width, PW, of 8.3ms. Mounting contact located as specified in Note 1.
Note 3 Test conditions for voltage regulation are as follows: VZ measurements are made at 10%
and then at 50% of the IZ max value listed in the “Electrical Characteristic” table. The test
current time duration for each VZ measurement is 40 10ms (TA = +25C +8, 2C). Mount-
ing contact located as specified in Note 1.
Device
Number
Nominal
Zener
Voltage
VZ @ IZT
(Note 1)
Test
Current
IZT
Max Zener Impedance
Max Reverse
Leakage Current Max Surge
Current
ir
(Note 2)
Max
Voltage
Regulation
VZ
(Note 3)
Max
Regulator
Current
IZM
ZZT @ IZT
(Note 1)
ZZK @ IZK = 1mA
(Note 1) IR@V
R
Volts mA AVolts Amps Volt mA
1N5341B 6.2 200 1200 1 3 12.4 0.1 765
1N5342B 6.8 175 1200 10 5.2 11.5 0.15 700
1N5343B 7.5 175 1.5 200 10 5.7 10.7 0.15 630
1N5344B 8.2 150 1.5 200 10 6.2 10 0.2 580
1N5345B 8.7 150 2200 10 6.6 9.5 0.2 545
1N5346B 9.1 150 2150 7.5 6.9 9.2 0.22 520
1N5347B 10 125 2125 57.6 8.6 0.22 475
1N5348B 11 125 2.5 125 58.4 80.25 430
1N5349B 12 100 2.5 125 29.1 7.5 0.25 395
1N5350B 13 100 2.5 100 19.9 70.25 365
1N5351B 14 100 2.5 75 110.6 6.7 0.25 340
1N5352B 15 75 2.5 75 111.5 6.3 0.25 315
1N5353B 16 75 2.5 75 112.2 60.3 295
1N5354B 17 70 2.5 75 0.5 12.9 5.8 0.35 280
1N5355B 18 65 2.5 75 0.5 13.7 5.5 0.4 265
1N5356B 19 65 375 0.5 14.4 5.3 0.4 250
1N5357B 20 65 375 0.5 15.2 5.1 0.4 237
1N5358B 22 50 3.5 75 0.5 16.7 4.7 0.45 216
1N5359B 24 50 3.5 100 0.5 18.2 4.4 0.55 198
1N5360B 25 50 4110 0.5 19 4.3 0.55 190
1N5361B 27 50 5120 0.5 20.6 4.1 0.6 176
1N5362B 28 50 6130 0.5 21.2 3.9 0.6 170
1N5363B 30 40 8140 0.5 22.8 3.7 0.6 158
1N5364B 33 40 10 150 0.5 25.1 3.5 0.6 144
1N5365B 36 30 11 160 0.5 27.4 3.3 0.65 132
1N5366B 39 30 14 170 0.5 29.7 3.1 0.65 122
1N5367B 43 30 20 190 0.5 32.7 2.8 0.7 110
1N5368B 47 25 25 210 0.5 35.8 2.7 0.8 100
1N5369B 51 25 27 230 0.5 38.8 2.5 0.9 93
1N5370B 56 20 35 280 0.5 42.6 2.3 186
1N5371B 60 20 40 350 0.5 42.5 2.2 1.2 79
Note 1 Test conditions for zener voltage and impedance are as follows: IZ is applied 40 10ms prior
to reading. Mounting contacts are located 3/8” to 1/2” from the inside edge of mounting clips
to the body of the diode (TA = +25C +8, 2C).
Note 2 Surge current is specified as the maximum allowable peak, nonrecurrent squarewave cur-
rent with a pulse width, PW, of 8.3ms. Mounting contact located as specified in Note 1.
Note 3 Test conditions for voltage regulation are as follows: VZ measurements are made at 10%
and then at 50% of the IZ max value listed in the “Electrical Characteristic” table. The test
current time duration for each VZ measurement is 40 10ms (TA = +25C +8, 2C). Mount-
ing contact located as specified in Note 1.
Device
Number
Nominal
Zener
Voltage
VZ @ IZT
(Note 1)
Test
Current
IZT
Max Zener Impedance
Max Reverse
Leakage Current Max Surge
Current
ir
(Note 2)
Max
Voltage
Regulation
VZ
(Note 3)
Max
Regulator
Current
IZM
ZZT @ IZT
(Note 1)
ZZK @ IZK = 1mA
(Note 1) IR@V
R
Volts mA AVolts Amps Volt mA
1N5372B 62 20 42 400 0.5 47.1 2.1 1.35 76
1N5373B 68 20 44 500 0.5 51.7 21.5 70
1N5374B 75 20 45 620 0.5 56 1.9 1.6 63
1N5375B 82 15 65 720 0.5 62.2 1.8 1.8 58
1N5376B 87 15 75 760 0.5 66 1.7 254.5
1N5377B 91 15 75 760 0.5 69.2 1.6 2.2 52.5
1N5378B 100 12 90 800 0.5 76 1.5 2.5 47.5
1N5379B 110 12 125 1000 0.5 83.6 1.4 2.5 43
1N5380B 120 10 170 1150 0.5 91.2 1.3 2.5 39.5
1N5381B 130 10 190 1250 0.5 98.8 1.2 2.5 36.6
1N5382B 140 8230 1500 0.5 106 1.2 2.5 34
1N5383B 150 8330 1500 0.5 114 1.1 331.6
1N5384B 160 8350 1650 0.5 122 1.1 329.4
1N5385B 170 8380 1750 0.5 129 1 3 28
1N5386B 180 5430 1750 0.5 137 1 4 26.4
1N5387B 190 5450 1850 0.5 144 0.9 525
1N5388B 200 5480 1850 0.5 152 0.9 523.6
Note 1 Test conditions for zener voltage and impedance are as follows: IZ is applied 40 10ms prior
to reading. Mounting contacts are located 3/8” to 1/2” from the inside edge of mounting clips
to the body of the diode (TA = +25C +8, 2C).
Note 2 Surge current is specified as the maximum allowable peak, nonrecurrent squarewave cur-
rent with a pulse width, PW, of 8.3ms. Mounting contact located as specified in Note 1.
Note 3 Test conditions for voltage regulation are as follows: VZ measurements are made at 10%
and then at 50% of the IZ max value listed in the “Electrical Characteristic” table. The test
current time duration for each VZ measurement is 40 10ms (TA = +25C +8, 2C). Mount-
ing contact located as specified in Note 1.
Color Band Denotes Cathode
1.000
(25.4)
.370
(9.41)
.204 (5.19) Dia.040 (1.02) Dia