1N5333B thru 1N5388B Zener Diode, 5 Watt 5% Tolerance Features: D Zener Voltage: 3.3V to 200V D High Surge Current Capability Absolute Maximum Ratings: DC Power Dissipation (TL = +75C, Lead Length = 3/8"), PD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5W Derate Above 75C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40mW/C Forward Voltage (IF = 1A), VF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2V Operating Junction Temperature Range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65 to +200C Storage Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65 to +200C Electrical Characteristics: (TA = +25C unless otherwise specified) Max Reverse Leakage Current Nominal Zener Voltage VZ @ IZT (Note 1) Max Surge Current ir (Note 2) Max Voltage Regulation VZ (Note 3) Test Current IZT Max Regulator Current IZM ZZT @ IZT (Note 1) ZZK @ IZK = 1mA (Note 1) IR Volts mA A Volts Amps Volt mA 1N5333B 3.3 380 3.0 400 300 1 20 0.85 1440 1N5334B 3.6 350 2.5 500 150 1 18.7 0.8 1320 1N5335B 3.9 320 2 500 50 1 17.6 0.54 1220 1N5336B 4.3 290 2 500 10 1 16.4 0.49 1100 1N5337B 4.7 260 2 450 5 1 15.3 0.44 1010 1N5338B 5.1 240 1.5 400 1 1 14.4 0.39 930 1N5339B 5.6 220 1 400 1 2 13.4 0.25 865 Device Number Max Zener Impedance @ VR Note 1 Test conditions for zener voltage and impedance are as follows: IZ is applied 40 10ms prior to reading. Mounting contacts are located 3/8" to 1/2" from the inside edge of mounting clips to the body of the diode (TA = +25C +8, -2C). Note 2 Surge current is specified as the maximum allowable peak, non-recurrent square-wave current with a pulse width, PW, of 8.3ms. Mounting contact located as specified in Note 1. Note 3 Test conditions for voltage regulation are as follows: VZ measurements are made at 10% and then at 50% of the IZ max value listed in the "Electrical Characteristic" table. The test current time duration for each VZ measurement is 40 10ms (TA = +25C +8, -2C). Mounting contact located as specified in Note 1. Max Reverse Leakage Current Nominal Zener Voltage VZ @ IZT (Note 1) Max Surge Current ir (Note 2) Max Voltage Regulation VZ (Note 3) Test Current IZT Max Regulator Current IZM ZZT @ IZT (Note 1) ZZK @ IZK = 1mA (Note 1) IR Volts mA A Volts Amps Volt mA 1N5341B 6.2 200 1 200 1 3 12.4 0.1 765 1N5342B 6.8 175 1 200 10 5.2 11.5 0.15 700 1N5343B 7.5 175 1.5 200 10 5.7 10.7 0.15 630 1N5344B 8.2 150 1.5 200 10 6.2 10 0.2 580 1N5345B 8.7 150 2 200 10 6.6 9.5 0.2 545 1N5346B 9.1 150 2 150 7.5 6.9 9.2 0.22 520 1N5347B 10 125 2 125 5 7.6 8.6 0.22 475 1N5348B 11 125 2.5 125 5 8.4 8 0.25 430 1N5349B 12 100 2.5 125 2 9.1 7.5 0.25 395 1N5350B 13 100 2.5 100 1 9.9 7 0.25 365 1N5351B 14 100 2.5 75 1 10.6 6.7 0.25 340 1N5352B 15 75 2.5 75 1 11.5 6.3 0.25 315 1N5353B 16 75 2.5 75 1 12.2 6 0.3 295 1N5354B 17 70 2.5 75 0.5 12.9 5.8 0.35 280 1N5355B 18 65 2.5 75 0.5 13.7 5.5 0.4 265 1N5356B 19 65 3 75 0.5 14.4 5.3 0.4 250 1N5357B 20 65 3 75 0.5 15.2 5.1 0.4 237 1N5358B 22 50 3.5 75 0.5 16.7 4.7 0.45 216 1N5359B 24 50 3.5 100 0.5 18.2 4.4 0.55 198 1N5360B 25 50 4 110 0.5 19 4.3 0.55 190 1N5361B 27 50 5 120 0.5 20.6 4.1 0.6 176 1N5362B 28 50 6 130 0.5 21.2 3.9 0.6 170 1N5363B 30 40 8 140 0.5 22.8 3.7 0.6 158 1N5364B 33 40 10 150 0.5 25.1 3.5 0.6 144 1N5365B 36 30 11 160 0.5 27.4 3.3 0.65 132 1N5366B 39 30 14 170 0.5 29.7 3.1 0.65 122 1N5367B 43 30 20 190 0.5 32.7 2.8 0.7 110 1N5368B 47 25 25 210 0.5 35.8 2.7 0.8 100 1N5369B 51 25 27 230 0.5 38.8 2.5 0.9 93 1N5370B 56 20 35 280 0.5 42.6 2.3 1 86 1N5371B 60 20 40 350 0.5 42.5 2.2 1.2 79 Device Number Max Zener Impedance @ VR Note 1 Test conditions for zener voltage and impedance are as follows: IZ is applied 40 10ms prior to reading. Mounting contacts are located 3/8" to 1/2" from the inside edge of mounting clips to the body of the diode (TA = +25C +8, -2C). Note 2 Surge current is specified as the maximum allowable peak, non-recurrent square-wave current with a pulse width, PW, of 8.3ms. Mounting contact located as specified in Note 1. Note 3 Test conditions for voltage regulation are as follows: VZ measurements are made at 10% and then at 50% of the IZ max value listed in the "Electrical Characteristic" table. The test current time duration for each VZ measurement is 40 10ms (TA = +25C +8, -2C). Mounting contact located as specified in Note 1. Max Reverse Leakage Current Nominal Zener Voltage VZ @ IZT (Note 1) Max Surge Current ir (Note 2) Max Voltage Regulation VZ (Note 3) Test Current IZT Max Regulator Current IZM ZZT @ IZT (Note 1) ZZK @ IZK = 1mA (Note 1) IR Volts mA A Volts Amps Volt mA 1N5372B 62 20 42 400 0.5 47.1 2.1 1.35 76 1N5373B 68 20 44 500 0.5 51.7 2 1.5 70 1N5374B 75 20 45 620 0.5 56 1.9 1.6 63 1N5375B 82 15 65 720 0.5 62.2 1.8 1.8 58 1N5376B 87 15 75 760 0.5 66 1.7 2 54.5 1N5377B 91 15 75 760 0.5 69.2 1.6 2.2 52.5 1N5378B 100 12 90 800 0.5 76 1.5 2.5 47.5 1N5379B 110 12 125 1000 0.5 83.6 1.4 2.5 43 1N5380B 120 10 170 1150 0.5 91.2 1.3 2.5 39.5 1N5381B 130 10 190 1250 0.5 98.8 1.2 2.5 36.6 1N5382B 140 8 230 1500 0.5 106 1.2 2.5 34 1N5383B 150 8 330 1500 0.5 114 1.1 3 31.6 1N5384B 160 8 350 1650 0.5 122 1.1 3 29.4 1N5385B 170 8 380 1750 0.5 129 1 3 28 1N5386B 180 5 430 1750 0.5 137 1 4 26.4 1N5387B 190 5 450 1850 0.5 144 0.9 5 25 1N5388B 200 5 480 1850 0.5 152 0.9 5 23.6 Device Number Max Zener Impedance @ VR Note 1 Test conditions for zener voltage and impedance are as follows: IZ is applied 40 10ms prior to reading. Mounting contacts are located 3/8" to 1/2" from the inside edge of mounting clips to the body of the diode (TA = +25C +8, -2C). Note 2 Surge current is specified as the maximum allowable peak, non-recurrent square-wave current with a pulse width, PW, of 8.3ms. Mounting contact located as specified in Note 1. Note 3 Test conditions for voltage regulation are as follows: VZ measurements are made at 10% and then at 50% of the IZ max value listed in the "Electrical Characteristic" table. The test current time duration for each VZ measurement is 40 10ms (TA = +25C +8, -2C). Mounting contact located as specified in Note 1. 1.000 (25.4) .370 (9.41) .040 (1.02) Dia .204 (5.19) Dia Color Band Denotes Cathode