Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
GU 1 Form A Short Circuit Protection (AQV112KL)
ASCTB28E 201201-T
4. Turn off time vs. ambient temperature
characteristics
Measured portion: between terminals 4 and 6;
LED current: 10 mA; Load voltage: 10 V (DC);
Load current: 100 mA (DC)
5. LED operate current vs. ambient
temperature characteristics
Measured portion: between terminals 4 and 6;
Load current: 100 mA
6. LED turn off current vs. ambient temperature
characteristics
Measured portion: between terminals 4 and 6;
Load current: 100 mA
0
0.05
0.1
0.15
0.2
0.25
–40 –20
0.3
02040608085
Ambient temperature, °C
Turn off time, ms
0
0.5
1
1.5
2
2.5
–40 –20
3
02040608085
Ambient temperature, °C
LED operate current, mA
0
0.5
1
1.5
2
2.5
–40 –20
3
02040608085
Ambient temperature, °C
LED turn off current, mA
7. Off state leakage current vs. load voltage
characteristics
Measured portion: between terminals 4 and 6;
Ambient temperature: 25°C 77°F
8. Current vs. voltage characteristics of output
at MOS portion
Measured portion: between terminals 4 and 6;
Ambient temperature: 25°C 77°F
9. LED dropout voltage vs. ambient
temperature characteristics
Measured portion: between terminals 1 and 2;
LED current: 10 to 50 mA
20 30 40 50 60100
10-12
10-11
10-10
10-9
10-8
10-7
10-6
Load voltage, V
Off state leakage current, A
–0.6
–0.4
–0.2
0
0.2
0.4
0.6
–1 –0.5 0 0.5 1
Voltage, V
Current, A
1
1.2
1.3
–40 –20
1.5
020406080
1.1
1.4
85
Ambient temperature, °C
LED dropout voltage, V
50mA
30mA
20mA
10mA
10. Turn on time vs. LED forward current
characteristics
Measured portion: between terminals 4 and 6;
Load voltage: 10 V (DC); Load current: 100 mA (DC);
Ambient temperature: 25°C 77°F
11. Turn off time vs. LED forward current
characteristics
Measured portion: between terminals 4 and 6;
Load voltage: 10 V (DC); Load current: 100 mA (DC);
Ambient temperature: 25°C 77°F
12. Output capacitance vs. applied voltage
characteristics
Measured portion: between terminals 4 and 6;
Frequency: 1 MHz; Ambient temperature: 25°C 77°F
–1
4
3
2
1
0
5
01020304050
LED forward current, mA
Turn on time, ms
0
0.05
0.1
0.15
0.2
01020304050
LED forward current, mA
Turn off time, ms
0
100
200
300
400
500
0102030405060
Applied voltage, V
Output capacitance, pF
13. Short circuit peak current vs. time
characteristics
Measured portion: between terminals 4 and 6;
LED current: 10 mA; Load resistance: 0;
Ambient temperature: 25°C 77°F
14. Short current monitoring interval vs. time
characteristics
Measured portion: between terminals 4 and 6;
LED current: 10 mA; Load resistance: 0;
Ambient temperature: 25°C 77°F
1
1.5
2
VL=12V
VL=24V
VL=60V
2.5
3
4
3.5
0102030405060
Time, S
Short circuit peak current, A
VL=12V
VL=24V
VL=60V
0
5
10
15
20
30
25
0102030405060
Time, S
Short current monitoring interval, ms