POWEREX C380__X500 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 41.14.14 Phase Control SCR 310 Amperes Average 1600 Volts CATHODE POTENTIAL TERMINAL FOR .187 INCH / 4.75 MM NOM. PUSH-ON TYPE TERMINAL > F DIA. TYP. G OEEP TYP. ee B DIA. ee b* cin i = _ = x { | f to - | { md | iZ FOR .058 INCH / 1.47 MM DIA. NOM, ANODE PIN RECEPTACLE CASE NUMBER T62 STRIKE DISTANCE = .21 INCH / 5.3 MM MIN. NOMINAL DIMENSIONS CREEPAGE DISTANCE = 34 INCH / 8.6 MM MIN, SYM. A 8 C D E F G H InchES|| 75 | 163 | 1.44 [| 030 | 5007565 | 140 | 080 | 25 MM 90 | 44 | 366 | 076 | 2.70ne38 [356 | 203 | 25 | Scale = 2" C380_ _X500 (Outline Drawing) Ordering Information: Select the complete nine digit part number you desire from the table, i.e. C380PMX500 is a 1600 Volt, 310 Ampere Phase Control SCR. Voltage Current VoRM Type VrRam Code | It(av) C380__X500 200 B 310 400 D 600 M 800 N 1000 P 1200 PB 1400 PD 1600 PM C380__X500 Phase Control SCR 310 Amperes Average, 1600 Volts Description: Powerex Silicon Controlled Rectifiers (SCR) are designed for phase control applications. These are all-diffused, Press-Pak (Pow-R-Disc) devices employing the field-proven amplifying (di/namic) gate. Features: Low On-State Voltage High di/dt High dv/dt Hermetic Packaging OOoOdd Excellent Surge and I2 Ratings Applications: [] Power Supplies L] Battery Chargers P-67TAOSMEREX P-68 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 41.14.14 C380__ X500 Phase Control SCR 310 Amperes Average, 1600 Volts Absolute Maximum Ratings Symbol C380__X500 Units RMS On-State Current @ To = 83C lems) 500 Amperes Average On-State Current @ Tc = 83C Iriav) 310 Amperes Peak One-Cycle Surge (Non-Repetitive) On-State Current (60Hz) Itse4 500 Amperes Peak One-Cycle Surge (Non-Repetitive) On-State Current (50Hz) Irom 5000 Amperes Critical Rate-of-Rise of On-State Current (Non-Repetitive) di/dt 800 Amperes/ps Critical Rate-of-Rise of On-State Current (Repetitive) di/dt 500 Amperes/s lt (for Fusing), One Cycle at 6OHz It 125,000 Asec Peak Gate Power Dissipation Pom 10 Watts Average Gate Power Dissipation Pera) 2 Watts Storage Temperature Tst 40 to 150 C Operating Temperature Ty 40 to 125 C Mounting Force 720 to 880 Ib. Mounting Force 3.2 to 3.92 kN Electrical and Thermal Characteristics Characteristics Symbol Test Conditions C380__x500 Units VoltageBlocking State Maximums Forward Leakage, Peak loam Ty = 125C, V = Vorm 20 mA Reverse Leakage, Peak lane Ty = 125C, V = Vaan - 20 mA CurrentConducting State Maximums Peak On-State Voltage Vim Te = 125C, hy = 1500A, Duty Cycle = 0.01% 1.75 Volts Switching Typical Turn-On Delay ty To = 25C, ly = 100A, Voam = rated. 1 psec Gate Supply 10V Open Circuit, 250, 0.1 wsec max. rise time Min. Critical dv/dt exponential to Voru dv/dt Ty = 125C, Gate open circuited. 200 V/psec Thermal Maximum Thermal Resistance, double sided cooling Junction to Case Rosc 0.095 C/Watt Case to Sink, Lubricated Recs 0.02 C/Watt GateMaximum Parameters Gate Current to Trigger ler To. = 25C, Vp = 6V,R, = 30 150 mA Gate Voltage to Trigger Vor Te = 40C to 125C, Vp = 6V, RA, = 30 3.0 Volts Non-Triggering Gate Voltage Voom Ty = 125C, Rated Voam, RL = 1000 2 0.15 Volts Peak Forward Gate Current lata 10 Amperes Peak Reverse Gate Voltage Veam 5 VoltsTOWEREX Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 41.14.14 C380__X500 Phase Control SCR 310 Amperes Average, 1600 Volts MAXIMUM ON-STATE CHARACTERISTICS Ty = 125C INSTANTANEOUS ON-STATE VOLTAGE, Vu, (VOLTS) oO 101 102 10? 104 INSTANTANEOUS ON-STATE CURRENT, Ir, (AMPERES) MAXIMUM ALLOWABLE CASE TEMPERATURE (SINUSOIDAL WAVEFORM) 120 Double Side Cooling 110 100 80 70 60 55 MAXIMUM ALLOWABLE CASE TEMPERATURE, Tc, (C) 0 100 200 300 400 500 600 AVERAGE ON-STATE CURRENT, Ira, (AMPERES) MAXIMUM ALLOWABLE CASE TEMPERATURE (RECTANGULAR WAVEFORM) t T DCT Duty Cycte MAXIMUM ALLOWABLE CASE TEMPERATURE, Tc, (C) 100 200 300 400 800 #00 AVERAGE ON-STATE CURRENT, Irie, (AMPERES) MAXIMUM POWER DISSIPATION, Pavia), (WATTS) TRANSIENT THERMAL IMPEDANCE, Zion, ((C/WATT) MAXIMUM POWER DISSIPATION, Pavoaxy, (WATTS) = bh DOO io TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (JUNCTION TO CASE) Single Side Cooling Double Side Cooling 0 boi 01.02 .05.1 2 6 1 2 51020 50100 TIME, t, (SECONDS) MAXIMUM ON-STATE POWER DISSIPATION (SINUSOIDAL WAVEFORM) 1 60. 90 Conduction Angle = 30 | 10 20 40 6080100 200 400 6001000 AVERAGE ON-STATE CURRENT, Inj, (AMPERES) MAXIMUM ON-STATE POWER DISSIPATION (RECTANGULAR WAVEFORM) =1 3319 59 = 162 Percent Duty Cycle = 81/3- 10 20 40 6080100 200 4006001000 AVERAGE ON-STATE CURRENT, Ira., (AMPERES) P-69Oe Powerex, inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 41.14.14 C380_ _X500 Phase Control SCR 310 Amperes Average, 1600 Volts P-70 SEC x 1000 It RATING >/(C (A RMS)? > HALF SINEWAVE ON-STATE PEAK CURRENT (AMPERES x 1000) - SUB-CYCLE SURGE AND (?t RATINGS (RATED LOAD CONDITIONS) iS 2 3 4 8 PULSE WIDTH, t;, (msec) INSTANTANEOUS GATE VOLTAGE, Var, (VOLTS) GATE CHARACTERISTICS 100 0 40 20 gore souree > load line ct di/at OO 2 amp /us Te*Sus mn., 0.58 man. rise time. ig minimum) gote amp/ss Tp*Sus oi 2 4 aw INSTANTANEOUS GATE CURRENT, lar, (AMPERES) NOTES: 1, Maximum allowable gate power dissipation = 2 watts. 2. The locus of possible DC trigger paints lie outside the boundaries shown at various case temperatures. 3. Tp = Rectangular Gate Current Pulse Width.