SCN-800 800W Single Output With Parallel Function series Features : AC input range selected by switch Protections: Short circuit / Overload / Over voltage / Over temp. High reliability/ Low ripple noise Built-in remote sense function Built-in remote ON-OFF control Built-in parallel operation function Can adjust from 20~100% output voltage by external control 1-5V Forced air cooling by built-in DC fan Case coating with paint 2 years warranty SPECIFICATION ORDER NO. OUTPUT SCN-800-12 SCN-800-15 SCN-800-24 SAFETY MODEL NO. 800S-N012 800S-N015 800S-N024 800S-N048 DC VOLTAGE 12V 15V 24V 48V RATED CURRENT 66A 54A 33A 16.6A CURRENT RANGE 0 ~ 66A 0 ~ 54A 0 ~ 33A 0 ~ 16.6A RATED POWER 792W 810W 792W 796W 150mVp-p 240mVp-p 480mVp-p RIPPLE & NOISE (max.) Note.2 150mVp-p VOLTAGE ADJ. RANGE 5.0% typical adjustment by potentiometer 1.0% VOLTAGE TOLERANCE Note.3 1.0% 20~100% adjustment by 1~5VDC external control 1.0% SCN-800-48 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 0.5% 0.5% 0.5% 0.5% SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load 90 ~ 130VAC / 180 ~ 260VAC selected by switch, 260 ~ 370VDC VOLTAGE RANGE INPUT FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 80% 17A / 115VAC 9A / 230VAC AC CURRENT INRUSH CURRENT (max.) 81% 3.5mA / 240VAC OVERLOAD 110 ~ 135% rated output power Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover OVER TEMPERATURE WORKING TEMP. WORKING TEMP., HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 110 ~ 135% follow to output set up point Protection type : Shut down o/p voltage, re-power on to recover >100 / measure by heat sink, near transformer Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +65 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.04% / (0 ~ 50 ) 10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Design refer to UL1950, CSA22.2, IEC60950 I/P-O/P, I/P-FG:1500VAC I/P-O/P, I/P-FG, >100M Ohms / 500VDC / 25 SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION Design refer to FCC part 15 class A (Note. 4) HARMONIC CURRENT ---EMS IMMUNITY ---- NOTE 87% 60A / 230VAC LEAKAGE CURRENT (max.) PROTECTION OVER VOLTAGE OTHERS 85% / 70% RH MTBF 120khrs min. MIL-HDBK-217F (25 DIMENSION PACKING SPECIAL FUNCTION 291*132*68mm (L*W*H) 2.3kg; 8pcs/ 24kg /CARTON DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual) ) 1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.Tolerence: includes set up tolerance, line regulation, load regulation. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:SCN-800-SPEC 2007-11-01 http://store.iiic.cc/ SCN-800 800W Single Output With Parallel Function Mechanical Specification series Unit:mm 291 200 50.5 #6-32-4 M3(NUT)x3H-4 AC INPUT 30 VS+ VSVCI VCO GND PAR GND INH N FG 68 L 41 15.5 199.5 V ADJ 15 LED POS+ NEG- 291 32 9.5 M3(NUT)x3H-4 115 M6 7.5 NEG AC INPUT BOTTOM SIDE POS DC OUTPUT Air flow direction 132 250 9 Derating Curve External DC Control VS Output Voltage O.V.P. Vout 100 OUTPUT VOLTAGE (%) LOAD (%) 100 50 -10 0 10 20 30 Ta ( 40 50 80 non-linear 60 40 20 V 60 1 ) 2 3 4 5 EXTERNAL VOLTAGE(Typical) File Name:SCN-800-SPEC 2007-11-01 http://store.iiic.cc/ SCN-800 800W Single Output With Parallel Function series Control terminal instruction manual LOAD LOAD VS+ VSVCI VCO GND PAR GND INH VS+ VSVCI VCO GND PAR GND INH USING INTERNAL VOLTAGE CONTROL LOAD VS+ VSVCI VCO GND PAR GND INH ON/OFF CONTROL BY SWITCH REMOTE SENSING LOAD LOAD VS+ VSVCI VCO GND PAR GND INH ON/OFF SWITCH VS+ VSVCI VCO GND PAR GND INH H:ON L:OFF DC 1-5V OUTPUT VOLTAGE ADJUST WITH DC 1-5V ON/OFF CONTROL BY TRANSISTOR LOAD VS+ VSVCI VCO GND PAR GND INH VS+ VSVCI VCO GND PAR GND INH LOAD VS+ VSVCI VCO GND PAR GND INH VS+ VSVCI VCO GND PAR GND INH PARALLEL OPERATION WITH REMOTE SENSING VS+ VSVCI VCO GND PAR GND INH VS+ VSVCI VCO GND PAR GND INH PARALLEL OPERATION File Name:SCN-800-SPEC 2007-11-01 http://store.iiic.cc/