Product: 3092A
ControlBus™, Coax RG6, #18 Sol BCCS, PO Ins, QUAD AL Shld, PVC Jkt,
CMR
Product Description
ControlBus™, Coax RG6 18AWG (Solid) Bare Copper Covered Steel, PO Insulation, Overall Duofoil®+ Aluminum Braid(60%)+Overall Duofoil®+Aluminum
Braid(40%) Shield, PVC Outer Jacket, CMR
Technical Specifications
Product Overview
Suitable Applications: harsh environment, factory automation, ControlNet™, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the
high-speed, time-critical requirements necessary for ControlNet factory floor applications
Physical Characteristics (Overall)
Conductor
AWG Stranding Material Nominal Diameter No. of Coax
18 Solid BCCS - Bare Copper Covered Steel 0.04 in 1
Conductor Count: 1
Insulation
Material Nominal Diameter
PE - Polyethylene (Foam) 0.18 in
Table Notes: Gas Injected
Outer Shield Material
Type Layer Material Material Trade Name Coverage [%]
Tape 1Alum / Poly / Alum Bonded Duofoil® 100%
Braid 2Aluminum 60%
Tape 3Alum / Poly / Alum Duofoil® 100%
Braid 4Aluminum 40%
Outer Jacket Material
Material Nominal Diameter
PVC - Polyvinyl Chloride 0.298 in
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR Nominal Outer Shield DCR Outer Conductor DCR
28 Ohm/1000ft 3.6 Ohm/1000ft 3.6 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to Shield
16.2 pF/ft
Inductance
Nominal Inductance
0.097 µH/ft
Impedance
Nominal Characteristic Impedance
75 Ohm
Return Loss (RL)
Frequency [MHz] Min. Structural Return Loss (SRL)
5 - 50 MHz 23 dB
High Frequency (Nominal/Typical)
Frequency [MHz] Nom. Insertion Loss
1 MHz 0.35 dB/100ft
2 MHz 0.38 dB/100ft
5 MHz 0.45 dB/100ft
10 MHz 0.59 dB/100ft
20 MHz 0.86 dB/100ft
50 MHz 1.37 dB/100ft
100 Mhz MHz 1.97 dB/100ft
200 Mhz MHz 2.82 dB/100ft
300 MHz MHz 3.48 dB/100ft
400 Mhz MHz 4.04 dB/100ft
Delay
Nominal Delay Nominal Velocity of Propagation (VP) [%]
1.22 ns/ft 83.0%
High Freq
Min. SRL (Structural Return Loss)
23 dB
Voltage
UL Voltage Rating
300 V RMS
Temperature Range
UL Temp Rating: 75°C
Operating Temp Range: -30°C To +75°C
Mechanical Characteristics
Bulk Cable Weight: 34 lbs/1000ft
Max. Pull Tension: 117 lbs
Min Bend Radius/Minor Axis: 3 in
Standards
NEC/(UL) Compliance: CMR, CL2R, CMG
CEC/C(UL) Compliance: CMG
CPR Euroclass: Eca
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU
(ROHS II): Yes
EU Directive 2012/19/EU
(WEEE): Yes
EU Directive 2015/863/EU: Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes
EU RoHS Compliance Date
(yyyy-mm-dd): 2004-01-01
MII Order #39 (China RoHS): Yes
Suitability
Suitability - Aerial: Yes - When supported by messenger wire
Suitability - Burial: No
Suitability - Hazardous
Locations: No
Suitability - Indoor: Yes
Suitability - Outdoor: Yes
Suitability - Sunlight Resistance: Yes
Flammability, LS0H, Toxicity Testing
UL Flammability: UL 1666 Vertical Shaft
IEC Flammability: IEC 60332-1-2
UL voltage rating: 300 V RMS
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 3093A
Part Number
Variants
Item # Color Putup Type Length UPC
3092A 010500 Black Reel 500 ft 612825141372
3092A 0101000 Black Reel 1,000 ft 612825141334
3092A 0102000 Black Reel 2,000 ft 612825141358
3092A 0105000 Black Reel 5,000 ft 612825141389
3092A 01010000 Black Reel 10,000 ft 612825141341
3092A X7E500 Blue X7E Reel 500 ft 612825141303
3092A X7E1000 Blue X7E Reel 1,000 ft 612825141280
3092A X7E5000 Blue X7E Reel 5,000 ft 612825141310
Footnote: C - CRATE REEL PUT-UP.
History
Update and Revision: Revision Number: 0.314 Revision Date: 04-28-2020
© 2020 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.