POWR-PRO(R) Fuses CCMR Series POWR-PRO(R) Class CC and CD Fuses 600 VAC * Dual-Element, Time-Delay * 2/10 - 60 Amperes POWR-PRO(R) Fuses circuits than would be possible if using fast-acting fuses. CCMR series fuses provide superior protection in a fraction of the space required by other fuse classes. For example, when 600V three pole, 30 ampere Class R fuse blocks are replaced by Littelfuse Class CC fuse blocks, mounting space requirements may be reduced 70% or more. This is especially important when a panel contains control devices for many motors. In addition to the UL Listed smaller sizes, Littelfuse CCMR series fuses are now available in larger sizes -- from 35 to 60 amperes! No other fuse is available with this current carrying capacity in a package this small. In fact, the 60 ampere CCMR fuse is the smallest 60A fuse available rated at 600 volts. Applications CCMR series fuses are specifically designed to withstand sustained starting currents of small motors Provide short-circuit protection for motor branch circuits Use with IEC- and NEMA-rated motor controllers and contactors General purpose circuits up to 60 amps Features/Benefits For space saving protection of motor circuits up to 40 HP*, we recommend Littelfuse POWR-PRO CCMR series fuses. These fuses are the only true dual-element, time-delay fuses that come in a small package specifically engineered for motor branch circuit protection. CCMR series fuses provide Type 2 "No Damage" protection to both NEMA-rated and the more sensitive IEC (International Electrotechnical Commission) type motor circuit components. Rating for rating, CCMR fuses are the most current-limiting fuses available. They also provide superior short-circuit protection since their time-delay characteristics permit the use of smaller fuse ratings in motor * Space savings -- No other fuse class approved for branch circuit protection has a 600 volt rating and 300,000 A.I.R. in such a small package. * Extremely current-limiting -- Reduces damage caused by heating and magnetic effects of short-circuit currents. Stops damaging shortcircuit currents faster than any mechanical protective device. * Excellent time-delay -- Eliminates needless downtime caused by power surges or equipment demands. Permits selection of fuse sizes closer to actual load conditions, which provides better protection. * 300kA Interrupting Rating -- Littelfuse self-certified to 300,000 amperes as standard. Meets future trend towards higher available short-circuit currents. *Consult the Motor Protection Tables in the Fuseology section for specific motor sizing information Specifications Voltage Ratings: Ampere Ratings AC: 600 Volts DC: 250 Volts (CCMR 2 10 -- 2A) (CCMR 41 2 -- 10A) (CCMR 35 -- 60A) 300 Volts (CCMR 2 1 4 -- 4A) 500 Volts (CCMR 12 -- 30A) Interrupting Ratings: AC: 200,000 amperes rms symmetrical 300,000 amperes rms symmetrical (Littelfuse self-certified) DC: 20,000 amperes 2 10 -- 60 amperes Ampere Range: Approvals: AC: Standard 248-4, Class CC UL Listed 2 10 - 30 amps (File No: E81895) Standard 248, Class CD UL Listed 35 - 60 amps (File No: E81895) CSA Certified 2 10 - 60 amps (File No: LR29862) DC: Littelfuse self-certified 20 2 10 4 3 10 1 2 6 10 8 10 1 1 114 14 10 112 16 10 1 8 10 2 2 14 2 1 2 2 8 10 3 3 2 10 3 12 4 4 12 5 5 6 10 6 614 7 7 12 8 9 10 12 15 17 1 2 20 25 30 35 40 45 50 60 Example part number (series & amperage): CCMR 40 Recommended Fuse Blocks LPSC (CCMR 2 10 -- 30A) L60030C series (CCMR 2 10 -- 30A) L60060C series (CCMR 35 -- 60A) Refer to Blocks & Holders section of this catalog for additional information. www.littelfuse.com (c) 2005 Littelfuse * POWR-GARDTM Products Catalog POWR-PRO(R) Fuses CCMR Series POWR-PRO(R) Class CC and CD Fuses 600 VAC * Dual-Element, Time-Delay * 2/10 - 60 Amperes .25" (6.4 mm) 1.50" .41" 0-30A .850" (10.3 mm) POWR-PRO(R) Fuses (38.1 mm) 35-60A (21.6 mm) .125" (3.2 mm) .50" (12.7 mm) 1.880" (47.8 mm) Current-Limiting Effects of CCMR (600V) fuses Apparent RMS Symmetrical For Various Fuse Ratings Short Circuit Current* 2A 160 180 200 220 230 240 245 255 260 280 300 310 340 350 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 80,000 100,000 150,000 200,000 6 1 4 A 330 400 430 460 480 500 520 550 570 600 625 650 700 750 4A 190 220 250 260 280 290 300 310 330 340 360 380 420 440 10A 370 440 480 520 550 570 590 600 640 670 700 750 800 850 12A 525 600 675 720 750 800 825 850 875 900 1,000 1,050 1,150 1,200 15A 600 700 775 825 850 900 925 975 1,000 1,050 1,125 1,200 1,300 1,400 20A 625 725 800 850 900 950 975 1,000 1,100 1,125 1,200 1,250 1,400 1,450 30A 750 875 950 1,000 1,050 1,125 1,175 1,200 1,300 1,350 1,400 1,500 1,600 1,750 1000000 800000 600000 60A 8/10A 1A 1 1/4A 1 1/2A 1 8/10A 2A 2 1/2A 3A 3 1/2A 4A 6A 8A 10A 12A 15A 20A 25A 30A 35A 1/2A 1/4A *Prospective RMS Symmetrical Amperes Short-Circuit Current Note: Data Derived from Peak Let-Thru Curves 1000 800 600 400000 300000 400 300 200000 100 80 60 100000 80000 60000 40 30 40000 30000 20 20000 10 8 6 10000 8000 6000 4 3 2000 1 .8 .6 4A 2A 1000 800 600 .4 .3 .2 200000 60000 80000 100000 30000 40000 20000 6000 8000 10000 3000 4000 600 800 1000 300 400 200 60 80 100 30 40 20 6 8 10 3 4 2 .6 .8 1 .3 .4 .2 .08 .1 2000 100 .02 600 800 1000 .04 .03 100 200 300 400 400 300 .1 .08 .06 .05 30A 20A 15A 12A 10A 6 1/4A 4000 3000 2 .01 60A 200 TIME IN SECONDS 200 CURRENT IN AMPERES (c) 2005 Littelfuse * POWR-GARDTM Products Catalog www.littelfuse.com 21