Rev. 10.25.11_87
NTS500 Series
1 of 4
Embedded Power for
Business-Critical Continuity
NTS500 Series
500 Watts
Special Features
• Activepowerfactorcorrection
• IECEN61000-3-2compliance
• Remotesense
• Powerfailandremoteinhibit
• Singlewirecurrentsharing
• Built-inEMIfilter
• Lowoutputripple
• 5Vstandby
• 12Vfanoutput
• Overvoltageprotection
• Overloadprotection
• Thermaloverloadprotection
• DCpowergood
• BuiltinOR-ingdiode/FET
• Optionalfancover(-CFsuffix)
Optionalendfancover(-CEFsuffix)
• PMBuscompliant
• DigitalI2C interface
• 2yearwarranty
• POEisolationonNTS508
Total Power: 200-500Watts
Input Voltage: 85-264Vac
120-300Vdc
# of Outputs: Single
Electrical Specifications
Safety
Input
Inputrange: 85-264Vac(widerange)
Frequency: 47-440Hz
Inrushcurrent: 50Amax.,coldstart@25°C
Efficiency: 85%typicalatfullload,nominalline
EMIfilter: FCCClassBconductedandradiated;CISPR22ClassB
conductedandradiated;EN55022ClassBconductedand
radiated;VDE0878PT3ClassBconductedandradiated.
Safetygroundleakage
current:
<0.5mA@50/60Hz,264Vacinput
Output
Maximumpower: 200Wforconvection;500Wwith30CFMforcedair
Adjustmentrange: ±5%
Standbyoutput: 5V@1Aconvection,2Aforcedair,regulated,±5%
Fanoutput: 12V@1A,-5%,+7%,0.5Afor-CFversion
Hold-uptime: 20ms@500Wload,115VACnominallineatfactoryvoltagesetting
Overloadprotection: Shortcircuitprotectiononalloutputs.Caseoverload
protected@115-130%abovepeakrating
Overvoltageprotection: 20-35%abovenominaloutput
• TUV: 60950
• cCSAus: 60950
• NEMKO: 60950
• CB: Certificate & report
• CE: Mark(LVD)
Rev. 10.25.11_87
NTS500 Series
2 of 4
LogicControl
Powerfailure: TTLlogicsignalgoeshigh100-500msecaftermainoutput.Itgoes
lowatleast4msecbeforelossofregulation
Remoteon/off: Requiresanexternalcontactclosuretoinhibitoutputs
DCOK: TTLlogicgoeshighaftertheoutputisinregulation.Itgoeslowwhen
thereislossofregulation.
Remotesense: Compensatesfor0.5Vleaddropmin.Willoperatewithoutremote
senseconnected.Reverseconnectionprotected.
Operatingtemperature: 0°to50°Cambientderateeachoutputas2.5%perdegreefrom
50°to70°C.
Storagetemperature: -40°Cto+85°C
Electromagnetic
susceptibility:
DesignedtomeetEN61000-4;
-2,-3,-4,-5,-6,-8,-11Level3
Humidity: Operating;non-condensing10%to90%RH
Vibration: Threeorthogonalaxes,sweepat
1oct/min,5min.dwellatfourmajorresonances
2Gpeak8Hzto500Hz,operational
EnvironmentalSpecifications
Embedded Power for
Business-Critical Continuity
OrderingInformation
Model
Number
Output
Voltage
Minimum
Load
MaximumLoad
withConvection
Cooling
MaximumLoad
with30CFM
ForcedAir
Peak
Load1Regulation2Ripple
P/P(PARD)3
NTS503 12V 0A 16.6A 41.7A 47A ±2% 120mV
NTS505 24V 0A 8.3A 20.8A 23.4A ±2% 240mV
NTS506 18V 0A 11.1A 27.7A 30A ±2 180mV
NTS508 48V 0A 4.2A 10.4A 11.7A ±2% 480mV
1.Peakcurrentlasting<30secondswithamaximum10%dutycycle.
2.At25°Cincludinginitialtolerance,linevoltage,loadcurrentsandoutputvoltagesadjustedtofactory
settings.
3.Peak-to-peakwith20MHzbandwidthand10µF(tantalumcapacitor)inparallelwitha0.1µFcapacitor
atratedlinevoltageandloadranges.
4.12Vfanoutputcannotbeusedabove50°Cwithconvectioncooling.
5. -CFsuffixaddedtothemodelnumberindicatescoverwithtopfan.-CEFsuffixaddedtothemodel
numberindicatescoverwithendmountedfancoverandACinlet
PinAssignments
Connector
CN1 PIN1 Line
PIN3 Neutral
PIN5 Ground
SK7 PIN1 V1SWP
PIN2 -RemoteSense
PIN3 +RemoteSense
PIN4 5VSB(standby)
PIN5 5VSBreturn
PIN6 +12V
PIN7 Common
PIN8 Inhibit
PIN9 DCpowergood(DCOK)
PIN10 PowerFail(POK)
SK8
PIN1 +12VFan
PIN2 Common
CN403 PIN1 5V_I2C
PIN2 Ground
PIN3 A2
PIN4 A0
PIN5 SVCC2_OR
PIN6 I2C_SDA
PIN7 I2C_SLC
PIN8 A1
PIN9 N/C
PIN10 +12V_RTN_CTRL
Adjustment Potentiometers
P1 +V1Outputadjust
Mating Connectors
SK4,5,6 Molex19141-0058
SK7 Control Molex90142-0010
signals PINS:90119-2110
or
Amp:87977-3
PINS:87309-8
or
*Landwin:2580S1003
PINS:2583T011R
SK8 JSTPHR-2
Pins:SPH-002T-PO.5S
CN403 JSTPHDR-10VS
Pins:JST5PHD-002T-PO.5-L/P
or
*Landwin2050S1000
Pins:2053T011P
*Whereavailable
EmersonConnectorKit#70-841-024includesallof
theabove(MolexforSK7)
Notes:
1. Specificationssubjecttochangewithoutnotice.
2. Alldimensionsininches(mm),toleranceis±.02”.
3. Specificationsareatfactorysettings
4. Mountingmaximuminsertiondepthis0.12”.
5. Warranty:2year
6. Weight:NTS50X-1.66lbs/0.75kg
NTS50X-CF-2.00lbs/0.9kg
NTS50X-CEF-2.26lbs/1.03kg
15
610
15
10
6
Rev. 10.25.11_87
NTS500 Series
3 of 4
Embedded Power for
Business-Critical Continuity
MechanicalDrawing
CN1
SK7
SK8
(CN403)
V out adj.
Rev. 10.25.11_87
NTS500 Series
4 of 4
Embedded Power for
Business-Critical Continuity
Americas
5810VanAllenWay
Carlsbad,CA92008
USA
Telephone:+17609304600
Facsimile: +17609300698
Europe (UK)
WaterfrontBusinessPark
MerryHill,Dudley
WestMidlands,DY51LX
UnitedKingdom
Telephone:+44(0)1384842211
Facsimile: +44(0)1384843355
Asia (HK)
14/F,LuPlaza
2WingYipStreet
KwunTong,Kowloon
HongKong
Telephone:+85221763333
Facsimile: +85221763888
Forglobalcontact,visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
Whileeveryprecautionhasbeentakentoensure
accuracyandcompletenessinthisliterature,Emerson
NetworkPowerassumesnoresponsibility,anddisclaims
allliabilityfordamagesresultingfromuseofthis
informationorforanyerrorsoromissions.
EmersonNetworkPowerandtheEmerson
NetworkPowerlogoaretrademarksand
servicemarksofEmersonElectricCo.
©2011EmersonElectricCo.
EmersonNetworkPower.com
EmbeddedComputing
Embedded Power
Monitoring
OutsidePlant
PowerSwitching&Controls
PrecisionCooling
Racks&IntegratedCabinets
Services
SurgeProtection
Emerson Network Power.
Thegloballeaderinenabling
business-criticalcontinuity.
ACPower
Connectivity
DCPower
a
b
ab
ab
ab
ab
ab
ab
a
b
9.15"
(232.3)
AIR FLOW DIRECTION
4.0"
(101.6)
1.61"
(40.9)
1.255"
(31.9)
0.862"
(21.9)
2.40"
(61) 6.244"
(158.6)
5.85"
(148.6)
0.862"
(21.9)
6.437"
(63.5)
0.752"
(19.1)
2.9"
(73.6)
4.7"
(119.6) 5.5"
(139.7)
M3 (8 places)
#6-32 (8 places)
MechanicalDrawing-CEFoption