1N4003-BC05
1 Amp Rectifier
200 Volts
DO-41
Features
Low Current Leakage
Metalurgically Bonded Construction
Low Cost
INCHES MM
DIM MIN MAX MIN MAX NOTE
C .280 .290 7.11 7.37
D .080 .107 2.00 2.70
E .070 .080 1.78 2.03
Maximum Ratings
Operating Temperature: -50°C to +125°C
Storage Temperature: -50°C to +150°C
Maximum Thermal Resistance; 20°C/W Junction To Lead
MCC
Catalog
Number
Device
Marking Maximum
Reccurrent
Peak
Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
1N4003-BC05 --- 200V 140V 200V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 1.0A TA = 75°C
Peak Forward Surge
Current IFSM 30A 8.3ms, half sine
Maximum
Instantaneous
Forward Voltage VF 1.1V IFM = 1.0A;
TJ = 25°C*
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR5.0µA
50µATJ = 25°C
TJ = 125°C
Typical Junction
Capacitance CJ15pF Measured at
1.0MHz, VR=4.0V
*Pulse test: Pulse width 300 µsec, Duty cycle 2%
A .373 .383 9.47 9.73
B .028 .034 .70 .90
F .274 .284 6.96 7.21
A
B
C
D
E
F
G
H
G .015 .025 .38 .64
H
47o
53o
47o
53o
omponents
20736 Marilla Street Chatsworth

 !"#
$% !"#
MCC
www.mccsemi.com
Revision: 3 2002/12/31
1N4003-BC05
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
Figure 2
Forward Derating Curve
017550 75 100 125
0
.2
.4
.6
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°C
150
.8
1.0
1.2
Junction Capacitance - pF versus
Reverse Voltage - Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
4
6
20
10
Amps
.4 .6 .8 1.0 1.2 1.4
.01
.02
.04
.06
.1
.2
.4
.6
1
2
25°C
Volts
Figure 3
Junction Capacitance
.1 .2 1.4 2 10 20 404 100 200
1
2
6
10
20
100
pF
Volts
60
40
4
400 1000
TJ=25°C
MCC
www.mccsemi.com
Revision: 3 2002/12/31
1N4003-BC05
1 100
4
0
10
5
20
30
8
Figure 5
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20 60 80
40
40
50
60
Figure 4
Typical Reverse Characteristics
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Volts
4
6
20
10
µAmps
20 120
40 60 80 100
.01
.02
.04
.06
.1
.2
.4
.6
1
2
TA=25°C
40
60
100
140
TA=100°C
MCC
www.mccsemi.com
Revision: 3 2002/12/31