MBR1030CT- MBR1060CT 10A SCHOTTKY BARRIER RECTIFIER Features and Benefits Mechanical Data * * * * * * * * Guard Ring Die Construction for Transient Protection Low Power Loss, High Efficiency High Surge Capability High Current Capability and Low Forward Voltage Drop For Use in Low Voltage, High Frequency Inverters, Free Wheeling, and Polarity Protection Applications Lead Free Finish, RoHS Compliant (Note 1) * * * * * Case: TO220AB Case Material: Molded Plastic. UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020 Polarity: As Marked on Body Terminals: Finish - Bright Tin. Solderable per MIL-STD-202, Method 208 Marking: Type Number Weight: 2.24 grams (approximate) TO220AB Pin 1 Pin 2 Pin 3 Top View Ordering Information Bottom View Case Device Schematic (Note 2) Device MBR10xxCT* Packaging TO220AB Shipping 50/Tube * xx = Device type, e.g. MBR1045CT Maximum Ratings @TA = 25C unless otherwise specified Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. Characteristic Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage (Note 3) RMS Reverse Voltage Average Rectified Output Current (Note 4) @ TC = 105C Non-Repetitive Peak Forward Surge Current 8.3ms Single Half Sine-Wave Superimposed on Rated Load Repetitive Peak Reverse Surge Current @ t 2.0s Symbol VRRM VRWM VR VR(RMS) IO MBR MBR MBR MBR MBR MBR 1030CT 1035CT 1040CT 1045CT 1050CT 1060CT 30 35 40 21 24.5 28 Unit 45 50 60 V 31.5 35 42 10 V A IFSM 125 A IRRM 1.0 A Thermal Characteristics Characteristic Typical Thermal Resistance Junction to Case (Note 4) Voltage Rate of Change (Rated VR) Operating and Storage Temperature Range Notes: Symbol RJC dV/dt TJ, TSTG Value 3.0 1000 -65 to +150 Unit K/W V/S C 1. EU Directive 2002/95/EC (RoHS). All applicable RoHS exemptions applied, see EU Directive 2002/95/EC Annex Notes 2. For packaging details, visit our website at http://www.diodes.com. 3. Short duration pulse test used to minimize self-heating effect. 4. Thermal resistance junction to case mounted on heatsink.. MBR1030CT-MBR1060CT Document number: DS30027 Rev. 4 - 2 1 of 4 www.diodes.com September 2011 (c) Diodes Incorporated MBR1030CT- MBR1060CT Electrical Characteristics @TA = 25C unless otherwise specified Characteristic Symbol Forward Voltage Drop @ IF = 5.0A, TC = 125C @ IF = 5.0A, TC = 25C @ IF = 10A, TC = 25C Peak Reverse Current @ TC = 25C at Rated DC Blocking Voltage (Note 3) @ TC = 125C Typical Total Capacitance (Note 5) 0.1 15 150 IRM CT Unit V mA pF I(AV), AVERAGE FORZWARD CURRENT (A) 10 Total Device 8 6 Per Element 4 2 0 IF, INSTANTANEOUS FORWARD CURRENT (A) IF, INSTANTANEOUS FORWARD CURRENT (A) 5. Measured at 1.0 MHz and applied reverse voltage of 4.0V DC and per element. 0 50 100 TC, CASE TEMPERATURE ( C) Fig. 1 Forward Current Derating Curve 150 IFSM, PEAK FORWARD SURGE CURRENT (A) Notes: VFM MBR MBR MBR MBR MBR MBR 1030CT 1035CT 1040CT 1045CT 1050CT 1060CT 0.70 0.57 0.80 0.70 0.95 0.84 MBR1050CT / MBR1060CT TJ = 150C TJ = 125C T J = 85C TJ = 25C 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 VF, INSTANTANEOUS FORWARD VOLTAGE (V) Fig. 3 Typical Forward Characteristics, per Element MBR1030CT-MBR1060CT Document number: DS30027 Rev. 4 - 2 2 of 4 www.diodes.com 100 MBR1030CT - MBR1045CT 10 TJ = 25C 1.0 0.1 0 0.4 0.8 1.2 1.6 VF, INSTANTANEOUS FORWARD VOLTAGE (V) Fig. 2 Typical Forward Characteristics, per Element 300 250 200 150 100 50 0 1 10 NUMBER OF CYCLES AT 60Hz Fig. 4 Max Non-Repetitive Surge Current 100 September 2011 (c) Diodes Incorporated MBR1030CT- MBR1060CT CT TOTAL CAPACITANCE (pF) 1,000 100 T J = 25 C f = 1.0MHz 10 0.1 1.0 10 100 VR, REVERSE VOLTAGE (V) Fig. 5 Typical Total Capacitance, per Element Package Outline Dimensions A E A1 Q SEATING PLANE P 16.00 0.20* H1 D D1 L1 L b2 e e1 MBR1030CT-MBR1060CT Document number: DS30027 Rev. 4 - 2 b c A2 *Guaranteed by TO-220AB leadframe design 3 of 4 www.diodes.com TO220AB Dim Min Typ Max A 3.56 4.82 A1 0.51 1.39 A2 2.04 2.92 b 0.39 0.81 1.01 b2 1.15 1.24 1.77 c 0.356 0.61 D 14.22 16.51 D1 8.39 9.01 e 2.54 e1 5.08 E 9.66 10.66 H1 5.85 6.85 L 12.70 14.73 L1 6.35 P 3.54 4.08 Q 2.54 3.42 All Dimensions in mm September 2011 (c) Diodes Incorporated MBR1030CT- MBR1060CT IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright (c) 2011, Diodes Incorporated www.diodes.com MBR1030CT-MBR1060CT Document number: DS30027 Rev. 4 - 2 4 of 4 www.diodes.com September 2011 (c) Diodes Incorporated