Y203-EN2-02-Katalog.book Seite 269 Mittwoch, 24. Mai 2006 2:22 14 CIMR-F7Z Varispeed F7 The industrial workhorse * * * * * * * * * * * Flux vector control with or without PG Silent operation. No current de-rating in silent mode. Torque control PID control Powerful application oriented functionality Stand still autotuning High slip braking Energy saving function. Standard LCD operator Standard RS485 communications - Modbus Fieldbus options: DeviceNet, PROFIBUS, CANOpen * Embedded OMRON PLC functionality with PLC option card. * PC configuration tool: CX-Drive. * CE, UL, and cUL marking Customized software * * The inverter software can be customized to meet specific application. Examples: * Electronic line shaft (S-8169) * Crane software (S-7071) * For detailed information please see CASE software section. Ratings * 200 V Class three-phase 0.4 to 110 kW * 400 V Class three-phase 0.4 to 300 kW System configuration 3G3IV-PCN329-E Inverter to PC cable CX-Drive JVOP-160 OY Digital operator (LCD display) JVOP-161-OY Digital operator (LED display) Line filter 3G3IV-PCN126/326 Digital operator extension cable Braking accessories Varispeed F7 Feedback speed option card Communication option cards Reference option card PLC option card U6 JP R11 U8 R70 R11 R6 U10 C26 R28 C28 R8 R120 + U1 R55 R75 R114 C2 R131 U14 R21 R5 R25 R15 R15 R15 1 R54 R56 R57 R40 R39 TR C17 R14 R7 C22 C16 + 2 C5 R20 R30 + C39 C24 U11 R78 R6 D6 C35 R99 R95 Y1 R52 PE 3 R1 R2 R5 C21 R3 R36 R35 C1 R TR 2 11 R11 R11 R10 0 7 C33 U10 U7 1 T1 JP3 C3 + + U9 U12 R1 05 R1 R1 0 0 U15 C11 R94 R97 C20 R96 R102 C12 JP5 C13 JP6 R95 RT4 U13 U17 COD E No. SI-N C10 73600 -C021 0 Varispeed F7 269 Y203-EN2-02-Katalog.book Seite 270 Mittwoch, 24. Mai 2006 2:22 14 Specifications Type designation CIMR - F7 Z 4 0P4 0 Inverter Protective enclosure 0: Open chassis type (IP00) 1: Enclosed type (IP20 / NEMA1) F7 series Specifications Z: European standard specifications ~ Max. applicable motor output 0P4: 0.4 kW 022: 22 kW ~ Voltage 2: 200 V class 4: 400 V class 300: 300 kW [ "P" indicates a decimal point ] 200 V class Model CIMR-F7Zo 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 Power supply Output characteristics Max. applicable motor output1 Inverter capacity kVA Rated current 2. 3. 4. 2018 2022 2030 2037 2045 2055 2075 2090 2110 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 1.2 1.6 2.7 3.7 5.7 8.8 12 17 22 27 32 44 55 69 82 110 130 160 3.2 4.1 7.0 9.6 15 23 31 45 58 71 85 115 145 180 215 283 346 4152 A Max. voltage 3-phase, 200/208/220/230/240 V (proportional to input voltage) Max. output frequency Heavy duty (low carrier, constant torque applications): 150 Hz max Normal duty 1 or 2 (high/reduced carrier, variable torque applications): 400 Hz max 3-phase 200/208/220/230/240 V, 50/60 Hz3 Rated input voltage and frequency Allowable voltage fluctuation +10%, -15% Allowable frequency fluctuation 5% Harmonic wave prevention 1. 2015 0.75 0.55 kW DC reactor Option Provided 12-pulse input Not available Available4 Our standard 4-pole motors are used for max. applicable motor output. Choose the inverter model whose rated current is allowable within the motor rated current range. 322 A in case of heavy duty mode When using the inverter of 200 V class 37 kW or more with a cooling fan of three-phase 230 V 50 Hz or 240 V 50/60 Hz power supply, a transformer for the cooling fan is required. A 3-wired transformer is required at 12-pulse input. 400 V class Model CIMR-F7Zo Power supply Output characteristics Max. applicable motor output1 2. 3. 4. 270 2.2 3.7 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 185 220 300 9.5 110 140 160 200 230 280 390 510 Inverter capacity kVA 1.4 1.6 2.8 4.0 5.8 6.6 13 18 24 30 34 46 57 69 85 1.8 2.1 3.7 5.3 7.6 8.7 12.5 17 24 31 39 45 60 75 91 112 150 180 216 260 304 370 5062 6753 Rated current A Max. voltage 3-phase, 380/400/415/440/460/480 V (proportional to input voltage) Max. output frequency Heavy duty (low carrier, constant torque applications): 150 Hz max Normal duty 1 or 2 (high/reduced carrier, variable torque applications): 400 Hz max 3-phase 380/400/415/440/460/480 V, 50/60 Hz Rated input voltage and frequency Allowable voltage fluctuation +10%, -15% Allowable frequency fluctuation 5% Harmonic wave prevention 1. 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 kW 0.55 0.75 1.5 DC reactor Option Provided 12-Pulse input Not available Available4 Our standard 4-pole motors are used for max. applicable motor output. Choose the inverter model whose rated current is allowable within the motor rated current range. 405 A in case of heavy duty mode 540 A in case of heavy duty mode A 3-wired transformer is required at 12-pulse input. Frequency inverters Y203-EN2-02-Katalog.book Seite 271 Mittwoch, 24. Mai 2006 2:22 14 Common specifications Enclosures 200 V class Model CIMR-F7Z Available as standard Open chassis type -IP00 Available by removing the upper and lower cover of enclosed type Model CIMR-F7Z 400 V class 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 Enclosed type - IP20) Available for option N/A Available as standard 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 Enclosed type - IP20 Available as standard Open chassis type - IP00 Available by removing the upper and lower cover of enclosed type Available for option N/A Available as standard Common specifications Model number CIMR-F7Z Control method Torque characteristics Control characteristics Speed control range Specification Sine wave PWM Closed loop vector control, open loop vector control, V/f control, V/f with PG control Heavy duty (low carrier, constant torque applications): 2 kHz carrier frequency, 150% overload for 1 minute, higher carrier frequency possible with current derating. Normal duty 1 (high carrier, variable torque applications): maximum carrier frequency, depending on inverter capacity, 120% overload for 1 minute. Normal duty 2 (variable torque applications): carrier frequency reduced, continuous overload capability increased 1:40 (V/f control) 1:100 (open loop vector control) 1:1000 (closed loop vector control) Speed control accuracy 3% (V/f control) 0.03% (V/f control with PG) 0.2% (open loop vector control) 0.02% (closed loop vector control) (25 C 10 C) Speed control response 5 Hz (control without PG) 30 Hz (control with PG) Torque limits Provided (4 quadrant steps can be changed by constant settings.) (Vector control) Torque accuracy 5% Frequency range 0.01 to 150 Hz (Heavy Duty), 0.01 to 400 Hz (Normal Duty 1 or 2) Frequency accuracy (temperature characteristics) Frequency setting resolution Digital references: 0.01% (-10 C to +40 C) Analog references: 0.1% (25C 10C) Digital references: 0.01 Hz Analog references: 0.025/50 Hz (11 bits plus sign) Output frequency resolution Overload capacity and maximum current Frequency setting signal Accel/decel time Braking torque Main control functions Protective functions 0 to +10V, -10 to +10 V, 4 to 20 mA, pulse train 0.01 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration time settings) Approximately 20% (approximately 125% with braking resistor option, braking transistor built into inverters of 18.5 kW or less) Restarting after momentary power loss, speed search, overtorque/undertorque detection, torque limits, 17-speed control (maximum), 4 acceleration and deceleration times, S-curve acceleration/deceleration, 3-wire control, auto-tuning (rotational or stationary), dwell function, cooling fan ON/OFF control, slip compensation, torque compensation, auto-restart after fault, jump frequencies, upper and lower limits for frequency references, DC braking for starting and stopping, high-slip braking, advanced PID control, energy-saving control, MEMOBUS communications (RS-485/422, 19.2 kbps maximum), 2 motor parameter sets, fault reset and parameter copy function. Motor protection Protection by electronic thermal overload relay. Instantaneous overcurrent protection Fuse blown protection Stops at approx. 200% of rated output current. Overload protection Stops for fuse blown. Heavy duty (low carrier, constant torque applications): 150% of rated output current for 1 minute Normal duty 1 (high carrier, variable torque applications): 120% of rated output current for 1 minute Normal duty 2 (high carrier, variable torque applications): 120% of rated output current for 1 minute, increased continuous output current. Overvoltage protection 200 class inverter: stops when main-circuit DC voltage is above 410 V. 400 class inverter: stops when main-circuit DC voltage is above 820 V. Undervoltage protection 200 class inverter: stops when main-circuit DC voltage is below 190 V. 400 class inverter: stops when main-circuit DC voltage is below 380 V. Momentary power loss ride through Cooling fin overheating Stall prevention Grounding protection Charge indicator Ambient operating temperature Environment 0.01 Hz Heavy duty (low carrier, constant torque applications): 150% of rated output current for 1 minute Normal duty 1 or 2 (high/reduced carrier, variable torque applications): 120% of rated output current for 1 minute Ambient operating humidity Storage temperature Application site Altitude Vibration Varispeed F7 By selecting the momentary power loss method, operation can be continued if power is restored within 2 s. Protection by thermistor. Stall prevention during acceleration, deceleration and running independently. Protection by electronic circuits. Illuminates when the main circuit DC voltage is approx. 10 VDC or more. -10 C to 40 C (enclosed wall-mounted type) -10 C to 45 C (open chassis type) 95% max. (with no condensation) - 20 C to + 60 C (short-term temperature during transportation) Indoor (no corrosive gas, dust, etc.) 1000 m max. 10 to 20 Hz, 9.8 m/s2 max.; 20 to 50 Hz, 2 m/s2 max 271 Y203-EN2-02-Katalog.book Seite 272 Mittwoch, 24. Mai 2006 2:22 14 Dimensions Open chassis type (IEC IP00) W1 H T1 D1 H2 H1 4-d (5) (5) W (5) D Fig 1 400 V class (3-phase) 200 V class (3-phase) Voltage 272 Max. applicable motor Inverter output kW CIMR-F7Z 0.4 ------ 0.75 ------ 1.5 ------ 2.2 ------ 3.7 ------ 5.5 ------ 7.5 ------ 11 ------ 15 ------ Fig Dimensions in mm W H D W1 H1 ------ 22 2022 0 250 400 30 2030 0 275 450 37 2037 0 45 2045 0 375 600 55 2055 0 75 2075 0 90 1 258 298 328 195 385 220 435 250 575 725 348 325 700 2090 0 500 850 358 370 820 110 2110 0 575 885 378 445 855 0.4 ------ 0.75 ------ 1.5 ------ 2.2 ------ 4.0 ------ 5.5 ------ 7.5 ------ 11 ------ 15 ----------4022 0 30 4030 0 37 4037 0 45 4045 0 55 4055 0 75 4075 0 90 4090 0 110 4110 0 132 4132 0 160 4160 0 185 4185 0 220 4220 0 300 4300 0 7.5 100 T1 d Approx. weight kg 2.3 M6 Cooling method 21 24 100 12.5 450 22 D1 Not available, please use the IP20 type removing the upper and lower cover 18.5 18.5 H2 57 3.2 63 M10 86 130 15 140 Fan cooled 87 4.5 108 M12 150 Not available, please use the IP20 type removing the upper and lower cover 275 450 258 220 435 325 550 283 260 535 450 725 348 325 700 100 7.5 1 21 2.3 M6 105 12.5 36 3.2 M10 130 500 850 358 370 820 575 916 378 445 855 710 1305 413 540 1270 916 1475 413 730 1440 88 89 Fan cooled 102 15 120 45.8 140 15 125.5 4.5 M12 160 260 280 405 Frequency inverters Y203-EN2-02-Katalog.book Seite 273 Mittwoch, 24. Mai 2006 2:22 14 Enclosed type (IEC IP20) F7Z 20P41 to F7Z25P51 F7Z 27P51 to F7Z20181 F7Z 20221 to F7Z20751 F7Z40P41 to F7Z45P51 F7Z47P51 to F7Z40181 F7Z40221 to F7Z41601 200 V class (3-phase) 0.4 400 V class (3-phase) H1 H3 (5) D (5) W Fig H D W1 (5) D Fig 3 Dimensions in mm W T1 D1 H10 3 H0 H H 4 D1 Fig 2 Max. applicable motor Inverter output kW CIMR-F7Z Varispeed F7 H2 H1 D H2 W1 W Fig 1 Voltage 4-d T1 T1 D1 H3 3 W1 H0 H H0 4 H2 W 4-d 4-d H1 W1 H0 H1 H2 H3 D1 T1 d Approx. weight kg Cooling method 3 Self cooled 20P4 1 0.75 20P7 1 1.5 21P5 1 2.2 22P2 1 157 1 140 280 3.7 23P7 1 5.5 25P5 1 7.5 27P5 1 11 2011 1 15 2015 1 18.5 2018 1 22 2022 1 254 535 30 2030 1 279 615 37 2037 1 45 2045 1 55 2055 1 75 2075 1 0.4 40P4 1 0.75 40P7 1 1.5 41P5 1 2.2 42P2 1 3.7 43P7 1 4.0 44P0 1 5.5 45P5 1 7.5 47P5 1 11 4011 1 15 4015 1 18.5 4018 1 22 4022 1 30 4030 1 37 4037 1 45 4045 1 55 4055 1 75 4075 1 90 4090 1 110 4110 1 132 4132 1 160 4160 1 39 126 280 266 7 --- 177 200 2 240 3 380 453 300 310 350 380 809 1027 186 300 285 207 216 350 335 298 328 348 195 400 385 220 450 435 250 600 575 8 0 10 0 7.5 30 165 725 140 280 700 302 300 126 197 78 7 2.3 M6 280 266 7 186 300 285 100 Fan cooled 27 62 130 3.2 M10 68 94 95 --- 8 2 11 24 39 177 200 6 65.5 209 12.5 325 4 135 157 1 M5 59 197 258 5 3 5 Self Cooled M5 59 4 65.5 6 78 10 --240 350 207 216 350 335 275 535 258 220 450 435 325 715 283 260 550 535 453 1027 348 325 725 700 7.5 85 105 100 2.3 M6 105 302 3.2 M10 130 504 1243 358 370 850 820 15 393 579 1324 378 445 918 855 45.8 408 96 97 122 4.5 140 Fan cooled 40 3 12.5 24 M12 130 170 273 Y203-EN2-02-Katalog.book Seite 274 Mittwoch, 24. Mai 2006 2:22 14 Filters Footprint / Flat filters C I A E B F H J L G Dimensions Model 200 V 400 V 1. K D 3G3RV-PFI3410-SE 1 A 330 355 408 330 330 355 355 408 386 B 141 206 236 141 141 206 206 236 115 C 46 60 80 46 46 50 50 65 260 D 281 302 355 281 281 302 302 355 306 E 313 336 390 313 313 336 336 390 240 F 115 175 205 115 115 175 175 205 235 G 5.5 6.5 6.5 5.5 5.5 6.5 6.5 6.5 12.0 3G3RV-PFI3600-SE 1 386 135 260 306 240 235 12.0 M12 - - - - 3G3RV-PFI3800-SE 1 564 160 300 516 420 275 9.0 M12 - - - - 3G3RV-PFI2035-SE 3G3RV-PFI2060-SE 3G3RV-PFI2100-SE 3G3RV-PFI3010-SE 3G3RV-PFI3018-SE 3G3RV-PFI3021-SE 3G3RV-PFI3035-SE 3G3RV-PFI3060-SE H M5 M6 M6 M5 M5 M4 M5 M6 M12 I 23 30 40 23 23 25 25 32.5 - J 126 186 216 126 126 186 186 216 - K 266 285 335 266 266 285 285 335 - L M5 M6 M6 M5 M5 M5 M6 M6 - Flat filters are not possible to be mounted as footprint filters. Bookform filters C D B H A E G F Model 200 V 400 V 274 3G3RV-PFI2130-SE 3G3RV-PFI2160-SE 3G3RV-PFI2200-SE 3G3RV-PFI3070-SE 3G3RV-PFI3100-SE 3G3RV-PFI3130-SE 3G3RV-PFI3170-SE 3G3RV-PFI3200-SE Dimensions A 366 451 610 331 326 370 451 610 B 180 170 240 185 150 180 170 240 C 90 120 130 80 90 90 120 130 D 280 350 480 300 240 280 350 480 E 310 380 518 329 270 310 380 518 F 65 102 90 55 65 65 102 90 G 6.5 6.5 8.2 6.5 6.5 6.5 6.5 8.3 H M10 M10 M10 M6 M10 M10 M10 M10 Frequency inverters Y203-EN2-02-Katalog.book Seite 275 Mittwoch, 24. Mai 2006 2:22 14 Braking unit 38 114.5 128 140 30 or more 59 100 or more 38 30 or more 138.5 3-lead wire inlet (20 dia. rubber bush) 100 or less 104 Lead wire inlet (28 dia. rubber bush) 2-lead wire inlet (35 dia. rubber bush) 100 73 138 150 Main circuit terminal M6 30 or more 111 156 200 50 30 or more 140 180 100 or less 66.5 4-M6 MTG holes 140 370 350 317 72 100 or more 4-M4 MTG holes Model CDBR-2110 B 12 36.5 Model CDBR-2015 B, -2022 B, -4030B, -4045 B Weight 8.5 Kg Weight 1.8 K Main circuit terminal M6 104 Lead wire inlet (28 dia. rubber bush) 2-lead wire inlet (35 dia. rubber bush) 156.5 118.5 50 30 or more 210 250 111 156 200 100 or more 30 or more 100 or more 9 36.5 355 317 4-M6 MTG holes 210 70 370 Model CDBR-4220 B Weight 12 Kg Braking resistor unit (inverter-mounted type) Note: Prepare mounting screws (2-M4x8 tapped screws). Screws 8mm or more and general metric screws cannot be used. Weight: 0.2 kg Model ERF-150WJ_ 200 or more Braking resistor unit (separately-installed type) MTG screw 150 or more A 30 or more C 150 50 or more A 50 or more 260 B C D MTG screw Weight kg 2011 266 543 246 340 M8 x 4 10 2015 356 543 336 340 M8 x 4 15 2018 446 543 426 340 M8 x 4 19 5.0 2022 446 543 426 340 M8 x 4 19 M6 x 4 7.5 4011 350 412 330 325 M6 x 4 16 335 M6 x 4 8.5 4015 350 412 330 325 M6 x 4 18 50 260 M5 x 3 3.0 4018 446 543 426 340 M8 x 4 19 350 75 335 M5 x 4 4.5 4022 446 543 426 340 M8 x 4 400 V class 19 130 350 75 335 M5 x 4 4.5 4030 356 956 336 740 M8 x 4 25 43P7 130 350 75 335 M5 x 4 5.0 4037 446 956 426 740 M8 x 4 33 45P5 250 350 200 332 M6 x 4 7.5 4045 446 956 426 740 M8 x 4 33 47P5 250 350 200 332 M6 x 4 8.5 A B C D MTG screw Weight kg 20P7 105 275 50 260 M5 x 3 3.0 21P5 130 350 75 335 M5 x 4 4.5 22P2 130 350 75 335 M5 x 4 4.5 23P7 130 350 75 335 M5 x 4 25P5 250 350 200 335 25P5 250 350 200 40P7 105 275 41P5 130 42P2 Varispeed F7 Model Voltage LKEB-_ Dimensions in mm A Model Voltage LKEB-_ 220 V class Dimensions in mm 200 or more C 30 or more B D B D 150 or more MTG screw 220 V class 400 V class 275 Y203-EN2-02-Katalog.book Seite 276 Mittwoch, 24. Mai 2006 2:22 14 Attachments Heatsink external mounting attachment The Varispeed G7 inverters under the 200/400 V class 15 kW or less need this attachment for mounting the heatsink externally. This attachment expands the outer dimensions of the width and height of the inverter. (Attachment is not required for inverters of 18.5 kW or more.) Wall CIMRG7C 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 H1 H Mounting panel W1 W D1 D2 D3 or more Attachment order code W H EZZ08676A 155 302 Dimensions in mm W1 H1 D1 D2 126 D3 37.4 40 57.4 60 290 122.6 EZZ08676B 210 330 180 316 136.1 63.4 70 EZZ08676C 250 392 216 372 133.6 76.4 85 37.4 40 57.4 60 EZZ08676A 155 302 126 290 122.6 EZZ08676B 210 330 180 316 136.1 63.4 70 EZZ08676C 250 392 216 372 133.6 76.4 85 2-5 dia. holes b a 4-d Tap a a b a (W3) A (W3) (H3) a H1 H (W3) (W2) A (H2) (W3) (W2) B H1 H B (19) (H2) a (H3) 4-d Tap (H3) Panel cut for external mounting of cooling fin (heatsink) W1 (W2) (W2) (59) W a a W1 W Fig 3 H1 H B (H2) a (H3) 4-d Tap (W3) A (W3) (W2) a a W1 W Fig 2 (H3) (H2) (W2) a (H3) Fig 1 CIMRF7Z 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 Fig W H Dimensions in mm W1 (W2) (W3) H1 (H2) (H3) 155 302 126 6 A B d 8.5 290 9.5 6 138 271 M5 6.5 316 7 197 298 8.5 372 9.5 10 233 353 M6 385 435 8 7.5 244 369 269 419 575 15 1 210 330 180 9 8.5 250 392 216 250 400 195 24.5 275 450 220 3 375 600 250 2 54.5 8 450 725 325 359 545 12.5 700 13.5 820 855 M10 434 673 500 850 370 575 885 445 57 55 8 10 19 15 484 782 M12 555 817 155 302 126 6 8.5 290 9.5 6 138 271 M5 6.5 316 7 197 298 10 233 353 1 210 330 180 9 8.5 250 392 216 8.5 372 9.5 275 450 220 435 325 550 260 8 535 450 725 325 54.5 8 700 13.5 12.5 434 673 M10 24.5 269 419 M6 3 8 7.5 309 519 2 3 500 850 370 57 8 820 19 15 484 782 575 925 445 55 10 895 1 15 555 817 M12 1.The sizes are different between the top and the bottom. Refer Fig 3 276 Frequency inverters Y203-EN2-02-Katalog.book Seite 277 Mittwoch, 24. Mai 2006 2:22 14 Installation Standard connections DC reactor to improve input power factor (optional) Braking resistor unit (optional) U X Short-circuit bar Main contactor T 1 2 B1 B2 Fuses L1 3-phase power 380 to 480 V L2 50/60 Hz L3 Line filter R/L1 U/T1 S/L2 V/T2 T/L3 W/T3 Varispeed F7 CIMR-F7Z47P5 PE MA Forward run/stop S1 Reverse run/stop S2 External fault S3 Fault reset S4 M1 Multi-step speed setting 1 S5 M2 Multi-step speed setting 2 S6 M3 Jog frequency selection S7 M4 SN M5 SC M6 MB Multi-function digital inputs [Factory setting] M SP E(G) +V 2k 3 Shield terminal Shield terminal 2 AC Analog input power supply +15V, 20 mA A2 P P Multi-function digital output 250 VAC, 1A max. 30 VDC, 1A max. Contact output 3 [Default : Frequency agree 1] Pulse train output 0 to 32kHz (2.2 k ) [Default: Output frequency] Adjustment, 20 k FM 1 4 to 20 mA Contact output 2 [Default : Zero speed] E(G) MP A1 Analog input 1: Master frequency reference 0 to +10V (20 k ) 0 to 10 V Contact output 1 [Default : Running] 24V RP Pulse train input [Default: Frequency reference input] 0 to 32 kHz Analog input setting adjustment 2k MC Fault contact output 250 VAC, 1A max. 30 VDC, 1A max. + - Multi-function analog output 1 (-10 to +10 V 2 mA / 4 to 20 mA) [Default: Output frequency 0 to +10 V] - Multi-function analog output 2 (-10 to +10 V 2 mA / 4 to 20 mA) [Default: Output current 0 to +10 V] FM Adjustment, 20 k Multi-function analog input 2 [Default: Frequency bias 4 to 20mA (250 )] AM AC AC + AM 0V -V Analog input power supply -15V, 20mA Terminating resistance R+ P MEMOBUS communication RS-485/422 RS+ P SIG Shielded wires Varispeed F7 P Twisted-pair Shielded wires 277 Y203-EN2-02-Katalog.book Seite 278 Mittwoch, 24. Mai 2006 2:22 14 Main circuit Voltage 200 V 400 V Model CIMR-F7Z 20P4 to 2018 2022, 2030 2037 to 2110 40P4 to 4018 4022 to 4055 4075 to 4300 Max. applicable motor output 0.4 to 18.5 kW 22 to 30 kW 37 to 110 kW 0.4 to 18.5 kW 22 to 55 kW 75 to 300 kW R/L1 Main circuit input power supply S/L2 T/L3 R1/L11 S1/L21 Main circuit input power supply Main circuit input power supply R-R1, S-S1 and T-T1 have been wired before shipment (See P59). --- Main circuit input power supply R-R1, S-S1 and T-T1 have been wired before shipment --- T1/L31 U/T1 Inverter output V/T2 Inverter output W/T3 B1 Braking resistor unit B2 ------ *DC reactor ( 1- 2) *DC power supply1 ( 1- ) --- 1 2 3 /l2 *DC power supply ( 1- 2)1 *Braking unit ( 3- ) 200 / l2 200 400 / l2 400 *DC reactor ( 1- 2) *DC power supply1 ( 1- ) --- 3. *DC power supply ( 1- 2)1 *Braking unit ( 3- ) --Cooling fan power supply3 --- -----Ground terminal (100 or less) 1. 2. ------ Cooling fan power supply2 ------ r/l1 Braking resistor unit 1DC power input does not conform to UL/c-UL listed standard. Cooling fan power supply r/l1- /l2: 200 to 220 VAC 50 Hz, 200 to 230 VAC 60 Hz (A transformer is required for 230 V 50 Hz or 240 V 50/60 Hz power supply.) Cooling fan power supply r/l1 - 200 / l2 200: 200 to 220 VAC 50 Hz, 200 to 230 VAC 60 Hz, r/l1 - Ground terminal (10 or less) 400 / l2 400: 380 to 480 VAC 50/60 Hz Main circuit configuration CIMR-F7Z2022, 2030 CIMR-F7Z40P4 to 4018 CIMR-F7Z4022 to 4055 CIMR-F7Z2037 to 2110 200 V class CIMR-F7Z20P4 to 2018 400 V class CIMR-F7Z4075 to 4300 278 Frequency inverters Y203-EN2-02-Katalog.book Seite 279 Mittwoch, 24. Mai 2006 2:22 14 Control circuite Analog input signals Digital input signals Type No. S1 S2 S3 S4 S5 S6 S7 SC SN SP +V Sequence output signals Analog output signals Pulse I/O RS-485/422 2. 3. 4. Function Forward run when ON; stopped when OFF. Reverse run/stop command Reverse run when ON; stopped when OFF. External fault input 1 Fault when ON. Fault reset 1 Reset when ON Multi-step speed reference 1 1 (master/auxiliary switch) Multi-step speed reference 2 1 Auxiliary frequency reference when ON. Multi-step setting 2 when ON. Signal level 24 VDC, 8 mA photocoupler Functions are selected by setting H1-01 to H1-05. Jog frequency reference 1 Jog frequency when ON. Digital input common - - Digital input neutral - - Digital input power supply +24 VDC power supply for digital inputs 24 VDC, 250 mA max. 2 15 V power output 15 V power supply for analog references -V -15 V power output -15 V power supply for analog references A1 A2 Frequency reference -10 to +10 V/100% 15 V (max. current: 20 mA) -15 V (max. current: 20 mA) -10 to +10 V(20 k) Multi-function analog input 4 to 20 mA/100% -10 V to +10 V/100% AC E(G) Function is selected by setting H3-09. 4 to 20 mA(250 ) -10 V to +10 V(20 k) Analog reference common - - Shield wire, optional ground line connection point Running signal (1NO contact) - - Zero speed Zero level (b2-01) or below when ON M5 M6 MA MB MC Speed agreement detection Within 2 Hz of set frequency when ON. Fault output signal Fault when CLOSED across MA and MC Fault when OPEN across MB and MC FM Multi-function analog output (frequency output) 0 to 10 V, 10V=100% output frequency AC AM Analog common - Multi-function analog output (current monitor) 0 to 10 V, 10V=200% inverter's rated Multi-function current analog output 2 RP Pulse input 4 H6-01 (frequency reference input) MP Pulse monitor H6-06 (output frequency) R+ RS+ SIG MEMOBUS communications input For 2-wire RS-485, short R+ and S+ as well as R- and S-. M1 1. Signal name Forward run/stop command Operating when ON. Multi-function contact outputs M2 M3 Relay contacts Contact capacity: 1 A max. at 250 VAC 1 A max. at 30 VDC 3 M4 4 to 20 mA current output MEMOBUS communications output Signal common Multi-function analog output 1 Relay contacts Contact capacity: 1 A max. at 250 VAC 1 A max. at 30 VDC 3 -10 to +10 V max. 5% 2 mA max. 0 to 32 kHz (3 k) High level voltage 3.5 to 13.2 V 0 to 32 kHz +15 V output (2.2 k) Differential input, photocoupler isolation Differential input, photocoupler isolation - - The default settings are given for terminals S3 to S7. For a 3-wire sequence, the default settings are a 3-wire sequence for S5, multi-step speed setting 1 for S6 and multi-step speed setting 2 for S7. Do not use this power supply for supplying any external equipment. When driving a reactive load, such as a relay coil with DC power supply, always insert a flywheel diode. Pulse input specifications are given in the following table. Low level voltage High level voltage H duty f Varispeed F7 0.0 to 0.8 V 3.5 to 13.2 V 30% to 70% 279 Y203-EN2-02-Katalog.book Seite 280 Mittwoch, 24. Mai 2006 2:22 14 Remove the upper and lower covers for the models of 15 kW or less in 200 V and 400 V classes. When using open chassis type inverters of 200 V/400 V 22 kW or more, secure spaces for eyebolts and wiring of the main circuit. Upper cover Internal heatsink Upper cover 55 C 50 mm or more 120 mm or more Air Upper part air temperature -10 to 55 C Heatsink Heatsink Open chassis type inverter Lower cover Inverter inlet temperature -10 to 45 C 45 C 30 mm or more 50 mm or more Peripheral temperature 40 C Lower cover 30 mm or more 120 mm or more Air Side spaces Top and bottom spaces Cover MTG screw Inverter heat loss 200 V class Model CIMR-F7Z 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 Inverter capacity kVA 1.2 1.6 2.7 3.7 5.7 8.8 12 17 22 27 32 44 55 69 82 110 130 160 A 3.2 4.1 7.0 9.6 15 23 31 45 58 71 85 115 145 180 215 283 346 415 Fin W 20 27 50 70 112 164 219 374 429 501 586 865 1015 1266 1588 2019 2437 2733 Inside unit W 39 42 50 59 74 84 113 170 183 211 274 352 411 505 619 838 997 1242 Total heat loss W 59 69 100 129 186 248 332 544 612 712 860 1217 1426 1771 2207 2857 3434 3975 Heat loss W Rated current Fin coding Self cooled 2110 Fan cooled 400 V class Heat loss W Model CIMR-F7Z 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 Inverter capacity kVA 1.4 1.6 2.8 4.0 5.8 6.0 9.5 13 18 24 30 34 46 57 69 85 110 140 160 200 230 280 390 510 A 1.8 2.1 3.7 5.3 7.6 8.0 12.5 17 24 31 39 45 60 75 91 112 150 180 216 260 304 370 506 675 Rated current Fin W 14 17 36 59 80 91 127 193 252 326 426 466 678 784 901 1203 1399 1614 2097 2388 2791 3237 3740 5838 Inside unit W 39 41 48 56 68 70 82 Total heat loss W 53 58 84 115 148 161 209 307 410 498 634 725 995 1144 1316 1698 1974 2285 2950 3390 3938 4609 5277 8158 Fin coding 114 158 172 208 259 317 360 415 495 575 671 853 1002 1147 1372 1537 2320 Self cooled Fan cooled Connections for braking units Connections for braking resistors Braking resistor Braking resistor overload relay trip contact (thermal relay trip contact) Braking resistor overload relay trip contact (thermal relay trip contact) MCCB * Set constant L8-01 to 1 (mounting type braking resistor protection enabled). * Set sequence to shutt off the power side at inverter fault contact output. Braking resistor unit Motor Varispeed F7 Braking resistor unit *3 Level Detector 3-phase Power Supply Varispeed F7 Braking unit 2*2 Braking unit 1 Cooling fin overheat contact (thermoswitch contact) 280 Cooling fin overheat contact (thermoswitch contact) Frequency inverters Y203-EN2-02-Katalog.book Seite 281 Mittwoch, 24. Mai 2006 2:22 14 AC reactor Application example Connection example Power supply capacity (kVA) AC reactor MCCB Motor AC Reactor required for power supply harmonics Varispeed F7 AC reactor not required Inverter capacity (kVA) 200 V class 400 V class Max. applicable motor output kW Current value A Inductance mH Max. applicable motor output kW Current value A Inductance mH 18.0 0.4 2.5 4.2 0.4 1.3 0.75 5 2.1 0.75 2.5 8.4 1.5 10 1.1 1.5 5 4.2 2.2 15 0.71 2.2 7.5 3.6 3.7 20 0.53 3.7 10 2.2 5.5 30 0.35 5.5 15 1.42 7.5 40 0.265 7.5 20 1.06 11 60 0.18 11 30 0.7 15 80 0.13 15 40 0.53 18.5 90 0.12 18.5 50 0.42 22 120 0.09 22 60 0.36 30 160 0.07 30 80 0.26 37 200 0.05 37 90 0.24 45 240 0.044 45 120 0.18 55 280 0.038 55 150 0.15 75 360 0.026 75 200 0.11 90 500 0.02 90/110 250 0.09 110 500 0.02 132/160 330 0.06 185 490 0.04 660 0.03 220 300 DC reactor DC reactor MCCB Motor Varispeed F7 Power supply capacity (kVA) Take off the common bar between G1 and G2, and wire as shown in the diagram. 0.4 0.75 400 V class Current value A Inductance mH 5.4 8 18 3 1.5 2.2 5.5 11 15 18.5 22 to 110 Varispeed F7 Max. applicable motor output kW 0.4 0.75 1.5 3.7 7.5 Without reactor Inverter capacity (kVA) 200 V class Max. applicable motor output kW With reactor for power supply coordination 2.2 3.7 36 1 72 0.5 90 0.4 Built-in 5.5 7.5 11 15 18.5 22 to 300 Current value A Inductance mH 3.2 28 5.7 11 12 6.3 23 3.6 33 1.9 47 1.3 Built-in 281 Y203-EN2-02-Katalog.book Seite 282 Mittwoch, 24. Mai 2006 2:22 14 Fuse installation To protect the inverter, it is recommended to use semiconductor fuses as shown in the table below Inverter type 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 Inverter type 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 282 FUSE Voltage (V) Current (A) I2t (A2s) 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 10 10 15 20 30 40 60 80 100 130 150 180 240 300 350 450 550 600 12~25 12~25 23~55 34~98 82~220 220~610 290~1300 450~5000 1200~7200 1800~7200 870~16200 1500~23000 2100~19000 2700~55000 4000~55000 7100~64000 11000~64000 13000~83000 Voltage (V) Current (A) I2t (A2s) 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 5 5 10 10 15 20 25 30 50 60 70 80 100 125 150 150 250 300 350 400 450 600 700 900 6~55 6~55 10~55 18~55 34~72 50~570 100~570 100~640 150~1300 400~1800 700~4100 240~5800 500~5800 750~5800 920~13000 1500~13000 3000~55000 3800~55000 5400~23000 7900~64000 14000~250000 20000~250000 34000~400000 52000~920000 FUSE Frequency inverters Y203-EN2-02-Katalog.book Seite 283 Mittwoch, 24. Mai 2006 2:22 14 Ordering information 3G3IV-PCN329-E Inverter to PC cable CX-Drive JVOP-160 OY Digital operator (LCD display) JVOP-161-OY Digital operator (LED display) 3G3IV-PCN126/326 Digital operator extension cable F F F F F Line filter Braking accessories Varispeed F7 A G Feedback speed option card Communication option cards PLC option card Reference option card T1 JP3 JP 1 R5 C21 R3 R36 R35 R1 R2 R11 U8 R70 R11 R6 U10 C26 R28 C28 R8 R120 + U1 R55 R75 R114 C2 R131 U14 R21 R5 R25 R15 R15 R15 1 R54 R56 R57 R40 R39 TR C17 R14 R7 C22 C16 + 2 C5 R20 R30 + C39 C24 U11 R78 R6 D6 C35 R99 R95 Y1 R52 PE 3 U10 U7 C1 R TR 2 11 R11 R11 R10 0 7 C33 U6 C3 + + U9 U12 05 R1 R1 R1 0 0 U15 C11 R94 R97 C20 R96 R102 C12 JP5 C13 JP6 R95 B C RT4 U13 U17 COD E No. SI-N C10 73600 -C021 0 D E Varispeed F7 200 V 400 V Specifications IP20 IP00 Varispeed F7 Model Specifications Model 0.55 Kw 3.2 A CIMR-F7Z20P41 0.55 Kw 1.8 A CIMR-F7Z40P41 0.75 Kw 4.1 A CIMR-F7Z20P71 0.75 Kw 2.1 A CIMR-F7Z40P71 1.5 Kw 7.0 A CIMR-F7Z21P51 1.5 Kw 3.7 A CIMR-F7Z41P51 2.2 Kw 9.6 A CIMR-F7Z22P21 2.2 Kw 5.3 A CIMR-F7Z42P21 3.7 Kw 15 A CIMR-F7Z23P71 3.7 Kw 7.6 A CIMR-F7Z43P71 5.5 Kw 23 A CIMR-F7Z25P51 4.0 Kw 8.7 A CIMR-F7Z44P01 7.5 Kw 31 A CIMR-F7Z27P51 5.5 Kw 12.5 A CIMR-F7Z45P51 11 Kw 45 A CIMR-F7Z20111 7.5 Kw 17 A CIMR-F7Z47P51 15 Kw 58 A CIMR-F7Z20151 11 Kw 24 A CIMR-F7Z40111 18.5 Kw 71 A CIMR-F7Z20181 15 Kw 31 A CIMR-F7Z40151 22 Kw 85 A CIMR-F7Z20220 18.5 Kw 39 A CIMR-F7Z40181 30 Kw 115 A CIMR-F7Z20300 22 Kw 45 A CIMR-F7Z40220 37 Kw 145 A CIMR-F7Z20370 30 Kw 60 A CIMR-F7Z40300 45 Kw 180 A CIMR-F7Z20450 37 Kw 75 A CIMR-F7Z40370 55 Kw 215 A CIMR-F7Z20550 45 Kw 91 A CIMR-F7Z40450 75 Kw 283 A CIMR-F7Z20750 55 Kw 112 A CIMR-F7Z40550 90 Kw 346 A CIMR-F7Z20900 75 Kw 150 A CIMR-F7Z40750 110 Kw 415 A CIMR-F7Z21100 90 Kw 180 A CIMR-F7Z40900 110 Kw 216 A CIMR-F7Z41100 132 Kw 260 A CIMR-F7Z41320 160 Kw 304 A CIMR-F7Z41600 185 Kw 370 A CIMR-F7Z41850 220 Kw 506 A CIMR-F7Z42200 300 Kw 675 A CIMR-F7Z43000 IP20 IP00 283 Y203-EN2-02-Katalog.book Seite 284 Mittwoch, 24. Mai 2006 2:22 14 A Line filters 200 V 400 V Inverter model Line filters Varispeed F7 Type CIMR-F7Z20P4 3G3RV-PFI3010-SE Inverter model EN55011 class Current (A) Weight (kg) B, 25 m A, 100 m 10 1.2 CIMR-F7Z20P7 CIMR-F7Z21P5 CIMR-F7Z22P2 3G3RV-PFI3018-SE B, 25 m A, 100 m 18 1.3 CIMR-F7Z23P7 3G3RV-PFI2035-SE B, 25 m A, 100 m 35 1.4 3G3RV-PFI2060-SE B, 25 m A, 100 m 60 3 3G3RV-PFI2100-SE B, 25 m A, 100 m 100 4.9 3G3RV-PFI2130-SE A, 100 m 130 4.3 CIMR-F7Z2037 3G3RV-PFI2160-SE A, 100 m 160 6.0 CIMR-F7Z2045 3G3RV-PFI2200-SE A, 100 m 200 11.0 CIMR-F7Z25P5 CIMR-F7Z27P5 CIMR-F7Z2011 CIMR-F7Z2015 CIMR-F7Z2018 CIMR-F7Z2022 CIMR-F7Z2030 CIMR-F7Z2055 CIMR-F7Z2075 3G3RV-PFI3400-SE A, 100 m 400 8.6 3G3RV-PFI3600-SE A, 100 m 600 11.0 CIMR-F7Z2090 CIMR-F7Z2110 Varispeed F7 CIMR-F7Z40P4 CIMR-F7Z40P7 CIMR-F7Z41P5 CIMR-F7Z42P2 CIMR-F7Z43P7 CIMR-F7Z44P0 CIMR-F7Z45P5 Line filter Model EN 55011 class* Current (A) Weight (kg) 3G3RV-PFI3010-SE B, 25 m A, 100 m 10 1.2 3G3RV-PFI3018-SE B, 25 m A, 100 m 18 1.3 21 1.8 35 2.2 60 4.0 CIMR-F7Z47P5 3G3RV-PFI3021-SE CIMR-F7Z4011 3G3RV-PFI3035-SE CIMR-F7Z4015 CIMR-F7Z4018 CIMR-F7Z4022 CIMR-F7Z4030 CIMR-F7Z4037 CIMR-F7Z4045 CIMR-F7Z4055 CIMR-F7Z4075 CIMR-F7Z4090 CIMR-F7Z4110 CIMR-F7Z4132 CIMR-F7Z4160 CIMR-F7Z4185 CIMR-F7Z4220 CIMR-F7Z4300 3G3RV-PFI3060-SE B, 25 m A, 100 m B, 25 m A, 100 m B, 25 m A, 100 m 3G3RV-PFI3070-SE B, 25 m A, 100 m 70 3.4 3G3RV-PFI3100-SE A, 100 m 100 4.5 3G3RV-PFI3130-SE 3G3RV-PFI3170-SE A, 100 m A, 100 m 130 170 4.7 6.0 3G3RV-PFI3200-SE A, 100 m 250 11 3G3RV-PFI3400-SE A, 100 m 400 8.5 3G3RV-PFI3600-SE A, 100 m 600 11.0 3G3RV-PFI3800-SE A, 100 m 800 31.0 B Feedback speed control cards Type Model PG-A2 / 3G3FV-PPGA2 Feedback speed control card PG-B2 / 3G3FV-PPGB2 PG-D2 / 3G3FV-PPGD2 PG-X2 / 3G3FV-PPGX2 PG-Z2 284 Description Function * Phase A pulse (single pulse) inputs (voltage, complementary, open collector input) * PG frequency range: Approx. 30 kHz max. [Power supply output for PG: +12 V, max. current 200 mA] * Pulse monitor output: +12 V, 20 mA * Phase A and B pulse inputs (exclusively for complementary input) * PG frequency range: Approx. 30 kHz max. [Power supply output for PG: +12 V, max. current 200 mA] * Pulse monitor output: Open collector, +24 V, Max. current 30 mA * Phase A pulse (differential pulse) input for V/f control (RS-422 input) * PG frequency range: Approx. 300 kHz max. PG speed controller card [Power supply output for PG: +5 V or +12 V, max. current 200 mA] (used for V/f control with PG or * Pulse monitor output: RS-422 flux vector) * Phase A, B and Z pulse (differential pulse) inputs (RS-422 input) * PG frequency range: Approx. 300 kHz max. [Power supply output for PG: +5 V or +12 V, max. current 200 mA] * Pulse monitor output: RS-422 * Phase A, B and Z pulse (differential pulse) inputs (RS-422 input) * PG frequency range: Approx. 300 kHz max. [Power supply output for PG: +5 V or +12 V, max. current 200 mA] * Pulse monitor output: RS-422 * Dual channel encoder: 1st channel A, B, Z / 2nd channel A, B, Z or open collector. Frequency inverters Y203-EN2-02-Katalog.book Seite 285 Mittwoch, 24. Mai 2006 2:22 14 C Communication option cards Model Description 3G3RV-PDRT2 DeviceNet option card SI-P1 PROFIBUS-DP option card SI-S1 CANopen option card SI-J LONWORKS option card CM090 Ethernet option card SI-T MECHATROLINK - II option board Communication option card Type 1. Function * Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through DeviceNet communication with the host controller. * Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFIBUS-DP communication with the host controller. * Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller. * Used for HVAC control, running or stopping the inverter, setting or referencing parameters, and monitoring output current, watt-hours, or similar items through LONWORKS communications with peripheral devices. * MODBUS TCP/IP ethernet interface unit. * High speed motion bus. * Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through MECHATROLINK-II communication with the host controller. * Host controller: TrajeXia, MCH or MP series1 Please refer to TrajeXia, MCH or MP series section for host controllers detailed information.t D Reference option cards Reference option card Type Model Description AI-14U / 3G3IV-PAI14U Analog input card AI-14B / 3G3IV-PAI14B DI-08 / 3G3IV-PDI08 DI-16H2 / 3G3IV-PDI16H2 Digital reference card Function * 2 channel high resolution analog input card * Channel 1: 0 to 10 V (20 K) * Channel 2: 4 to 20 mA (250 ) * Resolution 14 bit * 3 Channel high resolution analog input card * Signal level: -10 to +10V (20 K) s4 to 20 mA (250 ) *Resolution: 13 bit + sign * 8 bit digital speed reference input card * 16 bit digital speed reference input card E PLC option cards Type Model 3G3RV-P10ST8-E Description PLC option PLC option Function * Full PLC features, wireless installation and seamless access to the inverter parameters and analogue/digital inputs and outputs. * Embedded Compubus/S fieldbus * Standard OMRON tools can be used for programming * Same features as standard model with DeviceNet support. PLC option with DeviceNet 3G3RV-P10ST8-DRT-E Varispeed F7 285 Y203-EN2-02-Katalog.book Seite 286 Mittwoch, 24. Mai 2006 2:22 14 F Accessories Type Model JVOP-160-OY Description Function Panel cutout 70 44 Through Hole 20 14.5 2.5 JVOP-161-OY Panel 2-M3 MTG Holes 120 111 57 120 Digital operator 5 lines LCD digital operator 7 language support 70 15.8 6.4 7 segment LED digital operator (60) Accessories Panel cutout installation 3G3IV-PCN126 3G3IV-PCN326 Digital operator extension cable 1 meter 3 meters Extension cable to connect inverter and digital operator. 3G3IV-PCN329-E PC configuration cable Cable to connect the inverter to PC. F Computer software Software Type 286 Model Description Function CX-drive Computer software Configuration and monitoring software tool for drives. CX-One Computer software Complete OMRON automation software including CX-drive Frequency inverters Y203-EN2-02-Katalog.book Seite 287 Mittwoch, 24. Mai 2006 2:22 14 G Braking unit, braking resistor unit Braking resistor unit1 Separately-installed type (10 %ED, 10 sec. max.)3 Braking unit Inverter-mounted type (3 %ED, 10 sec max)2 Inverter Voltage 200 V class 400 V class 1. 2. 3. 4. 5. Max. applicable motor output kW Model CIMRF7Z_ Model No. of Model Resis- No. of CDBR_ used ERF-150WJ_ tance used Braking torque % Model LKEB_ Specifications No. of of resistor used Braking torque % Connectable min resistance value 0.4 20P4 201 200 1 220 20P7 70 W 200 1 220 48 0.75 20P7 201 200 1 125 20P7 70 W 200 1 125 48 1.5 21P5 101 100 1 125 21P5 260 W 100 1 125 48 2.2 22P2 700 70 1 120 22P2 260 W 70 1 120 16 3.7 23P7 620 62 1 100 23P7 390 W 40 1 125 16 5.5 25P5 25P5 520 W 30 1 115 16 7.5 27P5 27P5 780 W 20 1 125 9.6 11 2011 2011 2400 W 13.6 1 125 9.6 15 2015 2015 3000 W 10 1 125 9.6 18.5 2018 2015 3000 W 10 1 125 9.6 22 2022 2022B 1 2022 4800 W 6.8 1 125 6.4 30 2030 2015B 2 2015 3000 W 10 2 125 9.6 37 2037 2015B 2 2015 3000 W 10 2 100 9.6 45 2045 2022B 2 2022 4800 W 6.8 2 120 6.4 55 2055 2022B 2 2022 4800 W 6.8 2 100 6.4 75 2075 2110B 1 2022 4800 W 6.8 3 110 1.6 90 2090 2110B 1 2022 4800 W 6.8 4 120 1.6 110 2110 2110B 1 2018 4800 W 8 5 100 1.6 Built-in --- --- 0.4 40P4 751 750 1 230 40P7 70 W 750 1 230 96 0.75 40P7 751 750 1 130 40P7 70 W 750 1 130 96 1.5 41P5 401 400 1 125 41P5 260 W 400 1 125 64 2.2 42P2 301 300 1 115 42P2 260 W 250 1 135 64 3.7 43P7 4.0 44P0 201 200 1 110 43P7 390 W 150 1 135 32 5.5 45P5 45P5 520 W 100 1 135 32 7.5 47P5 47P5 780 W 75 1 130 32 11 4011 4011 1040 W 50 1 135 20 15 4015 4015 1560 W 40 1 125 20 18.5 4018 4018 4800 W 32 1 125 19.2 22 4022 4030B 1 4022 4800 W 27.2 1 125 19.2 30 4030 4030B 1 4030 6000 W 20 1 125 19.2 37 4037 4045B 1 4037 9600 W 16 1 125 12.8 45 4045 4045B 1 4045 9600 W 13.6 1 125 12.8 55 4055 4030B 2 4030 6000 W 75 4075 4045B 2 4045 9600 W 13.6 Built in --- --- 20 2 135 19.2 2 145 12.8 3.2 90 4090 4220B 1 4030 6000 W 20 3 100 110 4110 4220B 1 4030 6000 W 20 3 100 3.2 132 4132 4220B 1 4045 9600 W 13.6 4 140 3.2 160 4160 4220B 1 4045 9600 W 13.6 4 140 3.2 185 4185 4220B 1 4045 9600 W 13.6 4 120 3.2 220 4220 4220B 1 4037 9600 W 5 110 3.2 300 4300 4220B 2 4045 9600 W 13.6 6 110 3.2 16 When connecting a mounting type resistor or braking resistor unit, set system constant L3-04 to 0 (stall prevention disabled during deceleration). If operating without changing the constant, motor does not stop at set deceleration time. When connecting mounting type braking resistor, set system constant L8-01 to 1 (braking resistor protection enabled). Load factor during deceleration to stop a load with constant torque. With constant output or continuous regenerative braking, the load factor is smaller than the specified value. Resistance value per one braking unit. Select a resistance value that is larger than connectable minimum resistance value to obtain enough braking torque. For an application with large regenerative power such as hoisting, the braking torque or other items may exceed the capacity of a braking unit with a braking resistor in a standard combination (an result in capacity overload). Contact your OMRON representatives when the braking torque or any other item exceeds the values in the table. Varispeed F7 287 Y203-EN2-02-Katalog.book Seite 288 Mittwoch, 24. Mai 2006 2:22 14 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. I23E-EN-02 288 In the interest of product improvement, specifications are subject to change without notice. Frequency inverters Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: CIMR-F7Z42P21 B CIMR-F7Z47P5 B CIMR-F7Z47P5B CIMR-F7Z42P21B