IP138A SERIES
IP138ASERIES
IP338A SERIES
IP338A SERIES
LM138 SERIES
Document 10282
iss 1
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications. Load regulation is measured from the bottom of the package
for the TO–3 package and at the junction of the wide and narrow portion of the output lead for the TO–218 package.
2) Test Conditions unless othewise stated: VIN – VOUT = 5V , TJ= 25°C , IOUT = 2.5A.
Although power dissipation is internally limited, these specifications apply for dissipations of 50W and IMAX = 5A.
VREF Reference Voltage
∆VOUT Line Regulation 1
∆VIN
∆VOUT Load Regulation 1
∆IOUT
Thermal Regulation
Ripple Rejection
IADJ Adjust Pin Current
∆IADJ Adjust Pin Current
Change
IMIN Minimum Load
Current
ISC Current Limit
∆VOUT Temperature
∆TEMP Stability
∆VOUT Long Term Stability
∆TIME
enRMS Output Noise
(% of VOUT)
RθJC Thermal Resistance
Junction to Case
IOUT = 10mA
IOUT = 10mA to 5A
VIN – VOUT = 3V to 35V
P≤50W TJ= 0 to +125°C
VIN – VOUT = 3V to 35V
TJ= 0 to +125°C
IOUT = 10mA to 5A VOUT ≤5V
VOUT ≥5V
IOUT = 10mA to 5A VOUT ≤5V
TJ= 0 to +125°C VOUT ≥5V
tp= 20ms
CADJ = 0
VOUT = 10V TJ= 0 to +125°C
f = 120Hz CADJ = 10µF
TJ= 0 to +125°C
TJ= 0 to +125°C
IOUT = 10mA to 5A
VIN – VOUT = 3V to 35V
TJ= 0 to +125°C
VIN – VOUT = 35V
TJ= 0 to +125°C
VIN – VOUT ≤10V DC
TJ= 0 to +125°C 0.5ms Peak
VIN – VOUT = 30V
TJ= 0 to +125°C
TA= 125°C t = 1000 Hrs
f = 10 Hz to 10 kHz
K Package (TO–3)
V Package (TO–218)
1.238 1.25 1.262
1.225 1.250 1.270
0.005 0.010
0.020 0.040
515
0.1 0.3
20 30
0.3 0.6
0.002 0.020
60
60 75
45 100
0.2 5
3.5 10
58
612
0.25 1
12
0.3 1
0.001
1
1
1.190 1.240 1.290
0.005 0.030
0.020 0.060
525
0.1 0.5
20 50
0.3 1
0.002 0.020
60
60 75
45 100
0.2 5
3.5 10
58
612
1
1
0.3 1
0.003
1
1
V
V
% / V
mV
%
mV
%
%/W
dB
dB
µA
µA
mA
A
A
%
%
%
°C/W
LM338
IP338A IP338
Parameter Test Conditions Min. Typ. Max. Min. Typ. Max. Units