C60 gop Fyvell eNO miniatur circuit W6-UaQ2. C&OHCIIO breakers TIE-NSSS' OC GoWC Zas., Technical data @ current ratings: BSEN 60 - 898 1A to 634 at 30C @ voltage ratings: 240/415V AC @ breaking capacity: BSEN 60 - 898 Icn rating type voltage breaking (A) (VAC) capacity (A)_ 1-63 1P 240 10,000 1-63_2P,3P4P 240/415 10,000 _ @ positive contact indication: in accordance with the 16th Edition of the IEE Wiring Regulations (637-02-04, 537-03) @ operating cycles (0-C): on load 20,000 @ operating temperature: -30C to +70C B width in 9mm modules 1p 2P 3P 4P 2 4 6 8 @ weight (g): 1P 2P 3P 4P 110 220 340 450 @ auxiliaries VIGI residual current devices undervoltage trip release MN auxiliary switch OF alarm switch SD Shunt trip module MX Installation @ Direct panel mounting @ Panel mounting on symmetrical DIN rail @ in Merlin Gerin SP&N and TP&N distribution boards (except for 4 pole mcbs) and standard enclosures @ Information electrical auxiliaries Page 38 : accessories Page 39 - add on earth leakage (Vigi) Page-51 2 70 44 MERLIN GERIN| C60HB/C60HC/C60HD miniature circuit preakers CG60HB type B applications Protection and control of circuits against overloads and short circuits. Bw in commercial and industrial electrical distribution systems. win domestic installations. @ tripping characteristics: BSEN 60-898 type B: magnetic setting between 3 and 5 in. mw cable capacity: 1-254 = 25mm? 32 - 63A = 35mm? C60HB miniature circuit breaker Part Nos ratings 1P 2P 3P 4P (A) 1 C60HB 101 C60HB 201 C60HB 301 C60HB 401 2 C60HB 102 C60HB 202 C60HB 302 C60HB 402 4 C60HB 104 C60HB 204 C60HB 304 C60HB 404 6 C60HB 106 C60HB 206 C60HB 306 C60HB 406 10 C60HB 110 C60HB 210 C60HB 310 C60HB 410 16 C60HB 116 C60HB 216 C60HB 316 C60HB 416 20 C60HB 120 C60HB 220 C60HB 320 C60HB 420 25 C60HB 125 C60HB 225 C60HB 325 C60HB 425 32 C60HB 132 C60HB 232 C60HB 332 C60HB 432 40 C60HB 140 C60HB 240 C60HB 340 C60HB 440 50 C60HB 150 C60HB 250 C60HB 350 C60HB 450 63 | C60HB 163 C60HB 263 C60HB 363 C60HB 463 C60HC type C applications Protection and control of circuits against overloads and short circuits. @ in commercial and industrial electrical distribution systems. @ in applications with moderate inrush currents, such as certain lighting systems. @ tripping characteristics: BSEN 60-898 type C: magnetic setting between 5 and 10 In. W cable capacity: 1-25A = 25mm? 32 -63A = 35mm? C60HC miniature circuit breaker Part Nos ratings 1P 2P 3P (A) 1 C60HC 101 C60HC 201 C60HC 301 2 C60HC 102 * CE6OHC 202 C60HC 302 4 C60HC 104 C60HC 204 C60HC 304 6 C60HC 106 C60HC 206 C60HC 306 10 6OHC 110 - C60HC 210 C60HC 310 16 OHC 116 C60HC 216 C60HC 316 20 C60HC 120 C60HC 220 C60HC 320 25 C60HC 125 C60HC 225 CGaOHe 325 " 32 C60HC 132 C60HC 232 C 332 40 C60HC 140 C60HC 240 C60HC 340 50 C60HC 150 C6G0HC 250 C60HC 350 63 C60HC 163 C60HC 263 C60HC 363 C60HD type D applications Protection and control of circuits against overloads and short circuits. @ in commercial and industrial electrical distribution systems. @ in applications with high inrush currents, such as transformers, motors, certain lighting systems etc.. @ tripping characteristics: BSEN 60-898 type D: magnetic setting between 10 and 14 In. @ cable capacity: 1-25A = 25mm? 32 - 63A = 35mm? @ specification information C60H B, C, D. for motor applications, DC applications, de- rating and 400Hz, see technical data section page 129 C60HD miniature circuit breakers Part Nos ratings 1P 2P 3P (A) 1 C60HD 101 C60HD 201 C60HD 301 2 C&0HD 102 C60HD 202 C60HD 302 4 C60HD 104 C60HD 204 C60HD 304 6 C60HD 106 C60HD 206 C60HD 306 10 C6OHD 110 C60HD 210 C60HD 310 16 C6OHD 116 C60HD 216 C6CHD 316 20 C60HD 120 C60HD 220 C60HD 320 25 C60HD 125 C60HD 225 C60HD 325 32 C60HD 132 C60HD 232 C60HD 332 40 C60HD 140 C60HD 240 C60HD 340 50 C60HD 150 C60HD 250 C60HD 350 63 C60HD 163 C60HD 263 C60HD 363 MERLIN GERIN 37electrical auxiliaries for C60HB, C60HC and C60HD miniature circuit breakers and V40H combined mcb/rcd (see page 56) 26924 auxiliary switch (OF) a changeover switch which acts as an indicating or control device to monitor the 'ON' or 'OFF' positions of an meb. @ test function @ munted on the LHS of the mcb or meb/red. @ max number per mcb = 2 @ connection diagrams: page 142 i cable capacity 1 cable 2.5mm? 2 cables 1.5mm? alarm switch (SD) Man indicating device which monitors the tripping of an meb. This device offers the following: @ a red flag trip indicator B ability to reset without closing the mcb M@ test function @ mounted on the LHS of the mcb or meb/red. @ connection diagrams: page 142 @ cable capacity i cable 2.5mm? 2 cables 1.5mm? shunt trip selease (MX) B enables remote tripping 8 allows remote indication of the 'OFF' or 'ON' position of the mcb by using the same voltage as the one feeding the shunt trip (terminals 12 and 14) @ is equipped with a cut-off switch in series with the coil @ includes one auxiliary changeover switch (OF) Mf red flag trip indicator. Mi mounted on LHS of the mcb or meb/red. @ connection diagrams: page 142 i cable capacity 1 cable 2.5mm? 2 cables 1.5mm? undervoltage release (MN) M@ enables miniature circuit breaker to be tripped either when the auxiliary supply voltage drops or by the opening of a normally closed remote push button @ prevents the mcb from being switched 'ON' again if the undervoltage release supply is not present @ red flag trip indicator. @ mounted on the LHS of the mcb or meb/red. @ connection diagrams: page 142 li cable capacity 1 cable 2.5mm? 2 cables 1.5mm? No. of 9mm part no. SP ways _ modules Mp 1 OF 26924 contact rating (V) (A) 240 AC 6A 415 AC 3A 24 DC 6A 48 DC 2A 125 DC 1A No. of 9mm part no. SP ways modules Vo 1 SD 26927 contact rating (V) (A) 240 AC 6A 415 AC 3A 24 DC 6A 48 DC 2A 125 DC 1A No.of 9mm coil part no. SP ways modules voltage(V) 4 2 110/130V DC or 220/415 AC 26946 48V DC or 48-130V AC 26947 24V AC or DC 26948 Consumption of releases (Vv) (W or VA) MX 415 AC pickup _120 220.240 AC pickup _50 110.130 AC pickup _ 200 110.130 DC pickup 10 48 AC -DC pickup 22 24 AC-DC pickup 120 No. of ~ 9mm voltage part no. SP ways modules _(V) 1 2 220/240 AC 26960 48 AC 26961 48 DC 26962 Consumption of releases (W or VA) MN 220.240V AC _hold- 4.1 48 V AC hold - 4.3 48 VAC hold - 2.0 MERLIN GERINol et accessories for C60HB, C60HC and C60HD miniature circuit breakers locking attachment permits padiocking of the mcb in either part no. the ON! or 'OFF position. for C60H mobs (pack of 5) MGLA 4mm Hasp padiock for MGLA MGLAP for MCB/RCDs 26970 for C60H mebs (pack of 2) 20718 padlocking with 2 keys MGPL MGLA is suitable for use with C60 HB/C/D mcbs in distribution boards. : 20718 is suitable for use with C60 H 20718 B/C/D mebs in loose enclosures. terminal shield Completely covers terminals and is part no. fixed by a self retaining clip. pair of single pole 26975 1P, 2P, 3P and 4P versions available, pair of double pole 26976 all with built-in pole separation. pair of four pole 26978 pair of three pole 26975 + 26976 26975 26976 26978 sealable terminal screw shield Enables total shrouding of the terminal screws of 1P, 2P, 3P and 4P C0HB, C60HC and C6OHD mebs, and part no. combinations of these with VIGI (type for use with C60H mcbs ) C60) residual current devices. (1_bag of 8 shields) 26981 . for use with add-on VIGI _ residual current devices 6 (1 bag of 20 shields) 26982 7 8 b interpole barrier _ supplied in quantities of 10, they permit part no. _ insulation creepage distances to be for C60HB, C60HC increased. and C60HD mcbs 27001 27001 identification system ALL C60HB, C60HC and C60HD mcbs can accept up to a total of 10 marking accessories on each of their poles by fully utilising two separate locations. Refer to Telemecanique 01203 416255 N ! MERLIN GERIN 39iil he [O19 |S|a/o} 2\ 10,30,100,300mA == 3" C60H 220 + MGV 63 300 2 Application The range of VIGI C60 residual current devices simply clip on to the right hand side of any C60HB, C60HC and C60HD mcb, without adaptors, to provide a high level of protection against earth leakage faults in addition to the overload and over current protection provided by the mcb alone. The VIGI red has a residual current- operated electro-mechanical release which operates, without any auxiliary source of supply, to open a circuit automatically in the case of an earth leakage fault between phase and earth or neutral and earth greater than or equal to 10, 30, 100 or 300mA. VIGI modules - two pole for assembly with 1P or 2P mcbs rating sensitivity pRartn. (A) (mA) 25 10 MGV 25 010 2 63 30 MGV 63 030 2 63 100 MGV 63 100 2 63 300 MGV 63 300 2 MGV 63 0304 VIG! modules - four pole for assembly with 3P or 4P mcbs rating sensitivity part n. (A) (mA) 63 30 MGV 63 030 4 63 300. ~=MGV63 3004 Terminal screw shields available for VIGI reds. Refer to page 39 4P jg 54 pe 2P 1=36-| overall widths mceb + VIGI C60 module C60HB, C60HC AND C60HD mebs meb + VIGI 18mm 9mm poles C60 SP modules mm poles _ ways 1 2 3 6 54 2 2 4 8 72 4 8 72 3 4 6 12 108 4 4 7 14 126 Suitable for 2, 3 or 4 wire applications the VIGI C60 can be field adapted to operate in one of two modes: C automatic reset: VIGI is reset by meb toggle [J hand reset: VIGI is reset separately Othe 10, 30, 100 and 300mA units provide protection against indirect contact C the 10mA and 30mA units provide complementary protection against direct contact. NB: must not be used as the sole means of providing protection against direct contact (16th edition 412-06) Call sensitivities protect the installation against insulation faults CT the breaking capacity, tripping and other performance characteristics of the meb remain unaltered. Specifications B Rcd to BS EN61008 Technical data B voltage: 2P 110/240 50/60 Hz (415V consult us). 4P 240/415V 50/60 Hz M sensitivities: (non-adjustable) 30, 100 and 300 mA for current ratings up to 63A 10mA for current ratings up to 25A. unwanted tripping ALL VIGI modules are equipped with a filtering device preventing the risks of unwanted tripping due to transient voltages (lightning, line disturbances on other equipment...) and transient currents (from high capacitive circuits...). DC sensitive devices: consult us W@ cable capacities: 4P devices tunnel terminals for cables up to 35mm? 2P devices tunnel terminals for cables up to 25mm? Installation M on symmetrical DIN rail Bin all distribution boards and standard enclosures. @ direct panel mounting. WALL VIGI add-on red's can accept up to a total of 4 marking accessories on each of their poles. The following symbols are available: Blank,1-9, +, -, and A-Z. to order: Select the appropriate C60HB, C6O0HC or C60HD meb, then decide on the sen- sitivity of the VIGI add-on residual current device - and quote meb and VIGI red ref- erences. example: C60HB232 + MGV 63 300 2 = 10000A 2 pole 32A 300mA sensitivity rcd/mcb with overload, short circuit and earth leakage protection . AERLIN GERIN 51