SKAI 90 A2 GD06-W12DI
4 Rev. 10 – 20.04.2011 © by SEMIKRON
X1:13 PWR_VP INPUT
Auxiliary power supply / battery “+”
Supply voltage Vs
X1:14 PWR_GND Auxiliary power supply ground Ground of auxiliary power supply
X1:15 CMN_GND Ground for CMN_DIAG, CMN_HALT,
CMN_GPIO
Internally connected to PWR_GND
X1:16 CMN_TEMP OUTPUT
Temperature sensor signal CMN_TEMP
This pin is used to transmit the temperature
sensor analog signal.
Max. output current: 5 mA
Nominal voltage range: 0…10 V
X1:17 Reserved
X1:18 HB1_GND Ground for HB1_TOP, HB1_BOT Internally connected to PWR_GND
X1.19 Reserved
X1:20 HB2_GND Ground for HB2_TOP, HB2_BOT Internally connected to PWR_GND
X1:21 Reserved
X1:22 HB3_GND Ground for HB3_TOP, HB3_BOT Internally connected to PWR_GND
X1:23 CAN_L INPUT/OUTPUT
CAN interface LOW line
Input impedance = 121
Specification:
ISO 11783 (2.5V, 250 kbit/sec minimum,
quad twisted cable) or J1939/11 (250 kbit/sec
minimum, twisted shielded pair).
X1:24 PWR_VP INPUT
Auxiliary power supply / battery “+”
Supply voltage Vs
X1:25 PWR_GND Auxiliary power supply ground Ground of auxiliary power supply
X1:26 CMN_DIAG INPUT/OUTPUT
Single line CAN communication
[dominant/recessive]
Dominant/Recessive diagnose input/output
signal. All connected units can communicate
using this serial signal for setting/getting
parameters of the unit and reading error
information from unit registers.
X1:27 CMN_DCL OUTPUT
DC-Link voltage signal
[analog]
This pin is used to transmit the DC-Link
voltage level.
Max. output current: 5 mA
Nominal voltage range: 0….+10 V
X1:28 CMN_DCL_GND Ground for DC-Link voltage signal CMN_DCL Internally connected to PWR_GND
X1:29 HB1_I OUTPUT
Current sensor out for HB1
[analog]
Max. output current: 5 mA
Nominal voltage range: -10 … +10 V
X1:30 HB1_I_GND Ground for HB1_I Internally connected to PWR_GND
X1:31 HB2_I OUTPUT
Current sensor out for HB2
[analog]
Max. output current: 5 mA
Nominal voltage range: -10 … +10 V
X1:32 HB2_I_GND Ground for HB2_I Internally connected to PWR_GND
X1:33 HB3_I OUTPUT
Current sensor out for HB3
[analog]
Max. output current: 5 mA
Nominal voltage range: -10 … +10 V
X1:34 HB3_I_GND Ground for HB3_I Internally connected to PWR_GND
X1:35 CAN_H INPUT/OUTPUT
CAN interface HIGH line
Input impedance = 121
Specification:
ISO 11783 (2.5V, 250 kbit/sec minimum,
quad twisted cable) or J1939/11 (250 kbit/sec
minimum, twisted shielded pair).
PIN Signal Function Specifications