April 2008
4-4
For more information visit: www.eaton.com PG03300001E
IEC Contactors & Starters
4
XT IEC Power Control
Contactors and Starters
Cover Control
Non-combination Starters
Control Power Transformer (CPT) may be required.
Combination Starters
■Cover control for Combination Starters uses 10250T style
devices as standard.
■E22 style cover control options are available (Table 4-5).
■Selector switches are maintained with lever operators.
■Pushbuttons are momentary type with extended
pushbutton.
■The kit includes hardware and connecting wires (where
possible).
■For factory installed control devices other than shown
below, refer to Modification Codes, Page 16-40.
Table 4-3. Type 1 Non-combination Cover Control
For more available factory installed flange control, see Table 4-4.
Add Code Letter from the table below to Catalog Number for voltage —
Kits only. Example: C400T9B.
Table 4-4. Type 1 Combination and All Type 3R, 4X and 12
Cover Control
For Type 1 Non-combination field installation kits, see Table 4-3.
Add Code Letter from the table below to Catalog Number for voltage —
Kits only. Example: C400T9B.
Order Quantity (2) of C400T10.
Description Factory Installed
Flange Control
Field
Installation Kits
Position
9 Code
Catalog
Number
Non-reversing
No Cover Mounted Pilot Devices
START/STOP Pushbuttons
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
A
B
C
D
C400GK0
C400GK1
C400GK12
C400GK16
HAND/OFF/AUTO Selector Switch
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
H
J
K
C400GK3
C400GK32
C400GK36
Red RUN Pilot Light
Green OFF
Red RUN/Green OFF Pilot Lights
P
Q
R
C400GK42
C400GK41
C400GK46
Reversing
No Cover Mounted Pilot Devices
FOR/REV/STOP Pushbuttons
with 2 Red Pilot Lights
A
B
C
C400GK0
C400GR1
C400GR14
UP/STOP/DOWN Pushbuttons
with 2 Red Pilot Lights
E
F
C400GR2
C400GR24
Two Red Pilot Lights
One Green Pilot Light
P
Q
C400GK44
C400GK41
Rating Code
Letter
Rating Code
Letter
Rating Code
Letter
120V 60 Hz
208V 60 Hz
240V 60 Hz
A
E
B
277V 60 Hz
380V 50 Hz
H
L
480V 60 Hz
600V 60 Hz
C
D
Type 1 Cover Control
Description Factory Installed
Flange Control
Field
Installation Kits
Position
9 Code
Catalog
Number
Non-reversing
No Cover Mounted Pilot Devices
START/STOP Pushbuttons
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
A
B
C
D
—
C400T1
—
—
ON/OFF Pushbuttons
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
E
F
G
C400T2
—
—
HAND/OFF/AUTO Selector Switch
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
H
J
K
C400T12
—
—
START Pushbutton
ON Pushbutton
OFF Pushbutton
Red RUN Pilot Light
Green OFF
Red RUN/Green OFF Pilot Lights
L
M
N
P
Q
R
C400T3
C400T4
C400T5
C400T9
C400T10
C400T11
START/STOP Selector Switch
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
S
T
U
C400T13
—
—
ON/OFF Selector Switch
with Red RUN Pilot Light
with Red RUN/Green OFF Lights
V
W
X
C400T14
—
—
Reversing
No Cover Mounted Pilot Devices
FOR/REV/STOP Pushbuttons
with 2 Red Pilot Lights
with 2 Red/1 Green Pilot Lights
A
B
C
D
—
C400T6
—
—
UP/STOP/DOWN Pushbuttons
with 2 Red Pilot Lights
E
F
—
—
FOR/OFF/REV Selector Switch
with 2 Red Pilot Lights
with 2 Red/1 Green Pilot Lights
H
J
K
C400T15
—
—
Two Red Pilot Lights
One Green Pilot Light
Two Red/One Green Pilot Lights
OPEN/OFF/CLOSE Selector Switch
with 2 Red Pilot Lights
with 2 Red/1 Green Pilot Lights
P
Q
R
V
W
X
C400T10
—
C400T16
—
—
Rating Code
Letter
Rating Code
Letter
Rating Code
Letter
120V 60 Hz
208V 60 Hz
240V 60 Hz
A
E
B
277V 60 Hz
380V 50 Hz
H
L
480V 60 Hz
600V 60 Hz
C
D
10250T Selector Switch