IRHM9150 Pre-Irradiation
2www.irf.com
Electrical Characteristics @ Tj = 25°C (Unless Otherwise Specified)
Parameter Min Typ Max Units Test Conditions
BVDSS Drain-to-Source Breakdown V oltage -100 — — V VGS = 0V, ID =-1.0mA
∆BVDSS/∆TJTemperature Coefficient of Breakdown — -0.093 — V/°C Reference to 25°C, ID = -1.0mA
Voltage
RDS(on) Static Drain-to-Source On-State — — 0.080 VGS = -12V, ID = -14A➃
Resistance — — 0.085 Ω VGS = -12V, ID = -22A➃
VGS(th) Gate Threshold Voltage -2.0 — -4.0 V VDS = VGS, ID = -1.0mA
gfs Forward Transconductance 11 — — S ( ) V
DS >-15V, IDS = -14A ➃
IDSS Zero Gate Voltage Drain Current — — -2 5 VDS= -80V ,VGS=0V
— — -250 VDS = -80V,
VGS = 0V, TJ = 125°C
IGSS Gate-to-Source Leakage Forward — — -100 VGS = -20V
IGSS Gate-to-Source Leakage Reverse — — 100 VGS = 20V
QgTotal Gate Charge — — 200 VGS =-12V, ID = -22A
Qgs Gate-to-Source Charge — — 35 nC VDS = -50V
Qgd Gate-to-Drain (‘Miller’) Charge — — 48
td(on) Turn-On Delay Time — — 40 VDD = -50V, ID = -22A,
trRise Time — — 170 VGS =-12V, RG = 2.35Ω
td(off) Turn-Off Delay Time — — 190
tfFall Time — — 190
LS + LDTotal Inductance — 6.8 —
Ciss Input Capacitance — 4300 — VGS = 0V, VDS = -25V
Coss Output Capacitance — 1100 — pF f = 1.0MHz
Crss Reverse Transfer Capacitance — 310 —
nA
Ω
nH
ns
µA
Thermal Resistance
Parameter Min Typ Max Units Test Conditions
RthJC Junction-to-Case — — 0.83
RthJA Junction-to-Ambient — — 48 °C/W Typical socket mount
RthCS Case-to-Sink — 0.21 —
Source-Drain Diode Ratings and Characteristics
Parameter Min Typ Max Units Test Conditions
ISContinuous Source Current (Body Diode) — — -22
ISM Pulse Source Current (Body Diode) ➀— — -88
VSD Diode Forward V oltage — — -3.0 V Tj = 25°C, IS = -22A, VGS = 0V ➃
trr Reverse Recovery Time — — 300 nS Tj = 25°C, I F = -22A, di/dt ≤ -100A/µs
QRR Reverse Recovery Charge — — 1.5 µC VDD ≤ -50V ➃
ton Forward Turn-On Time Intrinsic turn-on time is negligible. Turn-on speed is substantially controlled by LS + LD.
A
Note: Corresponding Spice and Saber models are available on the G&S Website.
For footnotes refer to the last page
Measured from drain lead (6mm/0.25in. from
package) to source lead (6mm/0.25in. from
package)