Oxyride Dry Battery AA type Dimensions ZR6XT Unit:mm Max . 50.5 Min . 49.2 - 49.2 - 7.0 4.0 - 0.5 - 5.5 - 4.2 1.0 14.5 13.5 0.5 - 0.4 - is reference Discharge characteristic202 1000 Label will vary. Specifications 100 ZR6XT Nominal voltage 1.5V (Initial Voltage : 1.7V) Approximate weight 23g Terminal Insulation of terminal and exterior Duration (h) Model number 10 1.1V 1 10M500V.D.C 50.5( +0 -1.3 )mm Diameter 14.5( +0 -1.0 )mm Externals size 0.9V 1.2V - base + cap Height 1.0V 0.1 1 10 100 1000 10000 Load mA Caution Since the initial voltage is higher than standard batteries (1.7V), Oxyride Temperature characteristic 100 batteries may not be compatible with all electronic equipment. Test end voltage 1.0V Electronic equipment containing a remaining capacity indicator may not function properly when using Oxyride batteries. 10 When Oxyride batteries are used with an external-type retain more heat compared to use with Alkaline batteries. When equipment that operates on rechargeable batteries is changed with Oxyride batteries, the equipment may retain more heat compared to charging with Alkaline batteries. Duration (h) camera flash,the flash may not respond,or the flash may 45 0 20 -10 1 Do not use oxyride batteries with flashlights or headlamps that use standard light bulbs, excessive current will flow which will produce a bright light but reduce the life of the bulb and/or generate heat which may cause the bulb housing to warp. 0.1 Oxyride batteries may not function in certain clocks. 10 1000 100 10000 Load mW The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Dry Battery 2006 Discharge Curves 1.8 1.7 1.7 1.6 1.6 1.5 1.5 1.4 1.4 Voltage (V) Voltage (V) 1.8 1.3 1.2 1.1 Test end voltage 1.0V 0.8 Cut off voltage 0.7V Test temperature 202 0.7 0 10 20 30 Discharge schedule500mW 1.0 (Continuousness) 0.9 1.2 1.1 Discharge schedule1000mW 1.0 1.3 (Continuousness) Test end voltage 0.9 0.8 40 50 60 70 0.7 80 Cut off voltage 0.7V Test temperature 202 0 80 50 Duration minutes 1.7 1.7 1.6 1.6 1.5 1.5 1.4 1.4 Voltage (V) Voltage (V) 1.8 1.3 1.2 Discharge schedule250mW (Continuousness) 1.0 0.9 0.8 Test end voltage 1.0V Cut off voltage 0.7V Test temperature 202 100 200 1.2 Discharge schedule100mW 1.1 (Continuousness) Test end voltage 0.9 300 0.8 400 500 600 0.7 700 0 1.0V Cut off voltage 0.7V Test temperature 202 200 400 600 Duration minutes 800 1000 1200 1400 1600 1800 2000 Duration minutes 1.8 1.8 Discharge schedule1000mA 1.7 Discharge schedule100mA 1.7 (Continuousness) 1.6 1.5 Test end voltage 0.9V Cut off voltage 0.7V Test temperature 202 (Continuousness) 1.6 Voltage (V) Voltage (V) 1.4 1.3 1.2 Test end voltage 0.9V 1.5 Cut off voltage 0.7V 1.4 Test temperature 202 1.3 1.2 1.1 1.1 1.0 1.0 0.9 0.9 0.8 0.8 0.7 200 160 1.3 1.0 0.7 0 120 Duration minutes 1.8 1.1 1.0V 0 10 20 30 40 50 60 0.7 Duration minutes 0 200 400 600 800 1000 1200 1400 Duration minutes The data in this document are for descriptive purposes only and are not intended to make or imply any guarantee or warranty. Dry Battery 2006