2
20ETF..S HV QUIETIR Series
I2128 rev. A 01/2000
IF(AV) Max. Average Forward Current 20 A @ TC = 97° C, 180° conduction half sine wave
IFSM Max. Peak One Cycle Non-Repetitive 300 10ms Sine pulse, rated VRRM
applied
Surge Current 355 10ms Sine pulse, no voltage reapplied
I2t Max. I2t for fusing 450 10ms Sine pulse, rated VRRM
applied
635 10ms Sine pulse, no voltage reapplied
I2√t Max. I2√t for fusing 6350 A2√s t = 0.1 to 10ms, no voltage reapplied
Part Number
VRRM , maximum VRSM , maximum non repetitive IRRM
peak reverse voltage peak reverse voltage 150°C
VVmA
20ETF08S 800 900
20ETF10S 1000 1100 6
20ETF12S 1200 1300
Voltage Ratings
Absolute Maximum Ratings
Electrical Specifications
Recovery Characteristics
Parameters 20ETF..S Units Conditions
A
A2s
VFM Max. Forward Voltage Drop 1.31 V @ 20A, TJ = 25°C
rtForward slope resistance 11.88 mΩ
VF(TO) Threshold voltage 0.93 V
IRM Max. Reverse Leakage Current 0.1 TJ = 25 °C
6T
J = 150 °C
Parameters 20ETF..S Units Conditions
TJ = 150°C
VR = rated VRRM
mA
trr Reverse Recovery Time 400 ns IF @ 20Apk
Irr Reverse Recovery Current 6.1 A @ 25A/ µs
Qrr Reverse Recovery Charge 1.7 µC @ 25°C
S Snap Factor tb/ta 0.6 typical
Parameters 20ETF..S Units Conditions
ta tb
trr
t
Ifm
dir
dt Qrr
Irm (REC)