Absolute Maximum Ratings (Note)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales
Office/Distributors for availability and specifications.
Supply Voltage 7V
Input Voltage 5.5V
Operating Free Air Temperature Range
DM54 and 54 b55§Ctoa
125§C
DM74 0§Ctoa
70§C
Storage Temperature Range b65§Ctoa
150§C
Note:
The ‘‘Absolute Maximum Ratings’’ are those values
beyond which the safety of the device cannot be guaran-
teed. The device should not be operated at these limits. The
parametric values defined in the ‘‘Electrical Characteristics’’
table are not guaranteed at the absolute maximum ratings.
The ‘‘Recommended Operating Conditions’’ table will define
the conditions for actual device operation.
Recommended Operating Conditions
Symbol Parameter DM54174 DM74174 Units
Min Nom Max Min Nom Max
VCC Supply Voltage 4.5 5 5.5 4.75 5 5.25 V
VIH High Level Input Voltage 2 2 V
VIL Low Level Input Voltage 0.8 0.8 V
IOH High Level Output Current b0.8 b0.8 mA
IOL Low Level Output Current 16 16 mA
fCLK Clock Frequency (Note 4) 0 30 0 30 MHz
tWPulse Width Clock Low 25 25
(Note 4) Clock High 10 10 ns
Clear 20 20
tSU Data Setup Time (Note 4) 20 20 ns
tHData Hold Time (Note 4) 0 0 ns
tREL Clear Release Time (Note 4) 30 30 ns
TAFree Air Operating Temperature b55 125 0 70 §C
’174 Electrical Characteristics
over recommended operating free air temperature range (unless otherwise noted)
Symbol Parameter Conditions Min Typ Max Units
(Note 1)
VIInput Clamp Voltage VCC eMin, IIeb
12 mA b1.5 V
VOH High Level Output VCC eMin, IOH eMax 2.4 V
Voltage VIL eMax, VIH eMin
VOL Low Level Output VCC eMin, IOL eMax 0.4 V
Voltage VIH eMin, VIL eMax
IIInput Current @Max VCC eMax, VIe5.5V 1mA
Input Voltage
IIH High Level Input Current VCC eMax, VIe2.4V 40 mA
IIL Low Level Input Current VCC eMax, VIe0.4V b1.6 mA
IOS Short Circuit VCC eMax DM54 b20 b57 mA
Output Current (Note 2) DM74 b18 b57
ICC Supply Current VCC eMax (Note 3) 45 65 mA
Note 1: All typicals are at VCC e5V, TAe25§C.
Note 2: Not more than one output should be shorted at a time.
Note 3: With all outputs open and all DATA and CLEAR inputs at 4.5V, ICC is measured after a momentary ground, then 4.5V applied to the CLOCK input.
Note 4: TAe25§C and VCC e5V.
2