22 COREY STREET, MELROSE, MASSACHUSETTS 02176
PHONE (781) 665-1071 FAX (781) 665-7379
WEBSITE: http://www.cdi-diodes.com E-mail: mail@cdi-diodes.com
ELECTRICAL CHARACTERISTICS @ 25°C, unless otherwise specified
MAXIMUM RATINGS
Operating Temperature: -65°C to +175°C
Storage Temperature: -65°C to +200°C
Operating Current: 75 mA @ TA= + 25°C
Derating Factor: 0.5 mA/°C Above TA= + 25°C
Surge Current A: 1A, sine wave, Pw= 8.3ms
Surge Current B: 0.704A, square wave, Pw= 8.3ms
NOTE 1 IF= IR= 10 mA, RL= 100 ohms.
I R1 I R2 I R3 I R4 CAPACITANCE CAPACITANCE
@ 20 V dc @ 75 V dc @ 20 V @ 75 V @ 0 V @ 1.5 V
TA= 150°C TA= 150°C
nAµAµApFpF
25 0.5 35 75 4.0 2.8
Vf 1 Vf 2 t rr
VBR V RWM I0I F = 10 mA I F = 50 mA (Note 1)
Volts (min) Volts (pk) mA V dc V dc n sec
100 75 75 0.8 1.2 5
1N914
1N914 AVAILABLE IN JAN, JANTX, AND JANTXV
PER MIL-PRF-19500/116
SWITCHING DIODE
HERMETICALLY SEALED
DOUBLE PLUG CONSTRUCTION
METALLURGICALLY BONDED
FIGURE 1
DESIGN DATA
CASE: Hermetically sealed
glass case per MIL-S-19500/116
D0-35 outline
LEAD MATERIAL: Copper clad steel.
LEAD FINISH: Tin / Lead
THERMAL RESISTANCE: (ROJL):
250 ˚C/W maximum at L = .375
THERMAL IMPEDANCE: (ZOJX): 70
˚C/W maximum
POLARITY: Cathode end is banded.
MOUNTING POSITION: Any.
0.068/0.076
1.73/1.93
POLARITY
BAND
(CATHODE)
IN914
.3 .4 .5 .6 .7 .8 .9 1.0 1.1 1.2 1.3
VF - Forward Voltage (V)
FIGURE 2
Typical Forward Current
vs Forward Voltage
IF- Forward Current - (mA)
1000
100
10
1
0.1
150ºC
100ºC
25ºC
-65ºC
20 40 60 80 100 120 140
Percent of Reverse Working Voltage (%)
FIGURE 3
Typical Reverse Current
vs Reverse Voltage
IR- Reverse Current - (µA)
1000
100
10
1
0.1
.01
.001
150ºC
100ºC
25ºC
-65ºC
NOTE : All temperatures shown on graphs are
junction temperatures