Features * * * * * * DIN Rail Series Universal AC Input (85-264VAC) Protections: SCP, OVP, OLP, OTP DC OK Indicator LED with Relay Contacts 150% (180W) peak load capacity Built-in active PFC,PF>0,95 High effciency up to 92.5% AC/DC Converter REDIN120 Description These DIN-rail mounted power supplies have a robust case, 4mm screw terminal connectors and use high reliability components to give a long, trouble-free life. The REDIN120 can be end mounted to save rail space or side mounted for use in low-profile cabinets. The units can deliver up to 150% start-up power and allow n+1 parallel operation to increase the continuous output current or for supply redundancy. Relay contacts simplify DC OK monitoring. The REDIN120 series is designed for demanding commercial and industrial applications with UL508, UL60950, IEC60950 CB report and CE (LVD + EMC + RoHS) certifications. They come with a full 5-year warranty. 120 Watt DIN-Rail Power Supply Selection Guide Part nom. Input Output Output Rated Number Voltage Range Voltage Adjustability Current [VAC] [VDC] [VDC] [A] REDIN120-12 100-240 12 12-14 8.33 REDIN120-24 100-240 24 24-28 5 REDIN120-48 100-240 48 48-56 2.5 Efficiency typ. 230VAC full load [%] 89.5 91.5 92.5 Specifications (measured @ Ta= 25C, rated Vin, rated load and after warm up) BASIC CHARACTERISTICS Parameter Condition Input Voltage Range Return Voltage Immunity Inrush Current Typ. 85VAC Absolute Maximum Input Voltage Input Current Min. 264VAC 300VAC 375VDC max. 3s 115VAC, full load 230VAC, full load 12Vout 24Vout 48Vout 115VAC, cold start 230VAC, cold start 18V 35V 65V 40A 60A 115VAC 230VAC 1.5W 1.2W No Load Power Consumption Input Frequency Range 1.5A 0.65A 47Hz E224736 3W 3W UL60950-1 certified UL508 certified IEC/EN60950-1 certified 63Hz Output Voltage Trimming +16.67% Power Factor 115VAC 230VAC Start-up time 115VAC, full load 230VAC, full load Hold-up time 115VAC, full load 230VAC, full load Ripple and Noise (1) Max. 0.99 0.95 500ms 250ms 20ms 20ms 40ms 40ms 0 - 70C -25C 12Vout 100mVp-p 200mVp-p 0 - 70C -25C 24Vout 120mVp-p 240mVp-p -25C - 70C 48Vout 240mVp-p Notes: Note1: Measured at 20MHz bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 10F parallel capacitor continued on next page www.recom-power.com REV.: 3/2018 PDR-1 REDIN120 AC/DC Converter Series Specifications (measured @ Ta= 25C, rated Vin, rated load and after warm up) REDIN120-12 Efficiency vs. Load 100 16 Power Dissipation [W] 90 Efficiency [%] 80 70 60 50 40 115VAC 230VAC 264VAC 30 20 115VAC 230VAC 264VAC 14 12 10 8 6 4 2 0 10 0 Power Dissipation vs Load 18 0 10 20 30 40 50 60 70 80 90 100 80 90 100 80 90 100 Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] Input Current vs Load 1.4 1.0 115VAC 230VAC 1.0 Power Factor [%] Input Current [A] 1.2 0.8 0.6 0.4 0.8 0.6 115VAC 230VAC 0.4 0.2 0.2 0 Power Factor vs Load over Vin 1.2 0 1 2 3 4 0 5 0 10 20 30 Load Current [A] 40 50 60 70 Output Load [%] REDIN120-24 Efficiency vs. Load 100 16 Power Dissipation [W] 90 Efficiency [%] 80 70 60 50 40 115VAC 230VAC 264VAC 30 20 115VAC 230VAC 264VAC 14 12 10 8 6 4 2 0 10 0 Power Dissipation vs Load 18 0 10 20 30 40 50 60 70 Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] continued on next page www.recom-power.com REV.: 3/2018 PDR-2 REDIN120 AC/DC Converter Series Specifications (measured @ Ta= 25C, rated Vin, rated load and after warm up) REDIN120-24 Input Current vs Load 1.4 1.0 115VAC 230VAC 1.0 Power Factor [%] Input Current [A] 1.2 0.8 0.6 0.4 0.8 0.6 115VAC 230VAC 0.4 0.2 0.2 0 Power Factor vs Load over Vin 1.2 0 1 2 3 4 0 5 0 10 20 30 Load Current [A] 40 50 60 70 80 90 100 80 90 100 90 100 Output Load [%] REDIN120-48 Efficiency vs. Load 100 16 Power Dissipation [W] 90 Efficiency [%] 80 70 60 50 40 115VAC 230VAC 264VAC 30 20 115VAC 230VAC 264VAC 14 12 10 8 6 4 2 0 10 0 Power Dissipation vs Load 18 0 10 20 30 40 50 60 70 Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] Input Current vs Load 1.4 1.0 115VAC 230VAC 1.0 Power Factor [%] Input Current [A] 1.2 0.8 0.6 0.4 0.8 0.6 115VAC 230VAC 0.4 0.2 0.2 0 Power Factor vs Load over Vin 1.2 0 0.5 1 1.5 2 2.5 Load Current [A] www.recom-power.com 0 0 10 20 30 40 50 60 70 80 Output Load [%] REV.: 3/2018 PDR-3 REDIN120 AC/DC Converter Series Specifications (measured @ Ta= 25C, rated Vin, rated load and after warm up) REGULATION Parameter Condition Value Output Accuracy 0.25% typ. / 1% max. Line Regulation 0.1% typ. / 0.5% max. Load Regulation Transient Response 0% to 100% load 0.25% typ. / 1.0% max. 100Hz & 1kHz, 50% duty 1% typ. / 5% max. PROTECTION Parameter Input Fuse Condition Value internal (2) T5A, slow blow type Short Circuit Protection (SCP) hiccup mode (current limit) Over Voltage 100 Category (OVC) Iout [%] Over Voltage Protection (OVP) Over Load Protection (OLP) 100 12Vout 24Vout 48Vout 15-18VDC, hiccup mode 29-33VDC, hiccup mode 58-65VDC, hiccup mode OVC II Constant power (current limit) 1005C, detect on Heat-sink of power transistor; shut down O/P, auto recovery after temperature goes down Vout up to 90% of rated Vout Vout down to 80% of rated Vout Max. 30V/1A or 60V/0.3 or 30VAC/0.3A Resitive Load 3.0kVAC / 1minute 2.5kVAC / 1minute Vadj. 0.5kVAC / 1minute Output Power [%] 80 Over Temperature Protection (OTP) 75 60 85 Power OK LED 40 Isolation Voltage 20 12V 24V I/P to O/P 48V Isolation Resistance 0 -20 0 Leakage Current -25 20 40 60 70 80 100 REDIN120-12 REDIN120-24 REDIN120-48 14V 28V 56V I/P to PE, 240VAC 50Hz Ambient Temperature [C] Overload Capability ON (green) OFF (red) Relay Contact Rating I/P to O/P I/P to PE O/P to PE 10MW min. 0.1mA typ. / 0.25mA max. 1.0mA max. Notes: Note2: Refer to local wiring regulations if input over-current protection is also required Pout [%] y Time (x) [s] Pout (y) [%] 1 180 4 150 7 140 Typ Single Use Parallel Use (2 devices) Parallel Use (3 devices) 45 120 B 6A 6A 13A C 10A 10A 16A Maximum loading of automatic circuit breakers Circuit Breaker 100 Circuit Breaker Current Note: Values could change depending on local mains 0 x 60 Time [s] ENVIRONMENTAL Parameter Condition Operating Temperature Range (3) @ natural convection 0.1m/s Value full load -25C to +55C refer to derating graph -25C to +70C Temperature Coefficient Operating Altitude 0.03%/K 3000m (4) Operating Humidity non-condensing 20% - 90% RH continued on next page www.recom-power.com REV.: 3/2018 PDR-4 REDIN120 AC/DC Converter Series Specifications (measured @ Ta= 25C, rated Vin, rated load and after warm up) ENVIRONMENTAL Parameter Condition Value IP Rating IP20 Pollution Degree (PD) PD2 Shock 10-500Hz 2G, 60min. Vibration 10G /11ms, along x,y and z axis MTBF according to MIL-HDBK-217F, full load, 25C Thermal Derating Operating Altitude 150 100 Short time (3s) 80 75 70 B 100 Output Load [%] Output Load [%] 90 60 50 Pout 115VAC cont. Pout 230VAC cont. 40 30 A 80 60 A Ta<60C B Ta>55C 40 20 20 10 0 -40 300 x 10 hours -20 0 20 40 60 80 55 70 100 0 120 0 500 Ambient Temperature [C] Notes: Note3: Note4: 1000 1500 2000 2500 3000 Operating Altitude [m] UL Report certified temperature range: -25C to +50C. According to RECOM internal qualification the device is rated up to +70C with derating UL Report certified operating altitude: 5000m. According to RECOM internal qualificaion the device is rated up to 3000m. For altitude higher than 2000m, derating 30W for evey 1000m, or 5C/1000m SAFETY AND CERTIFICATIONS Certificate Type Report / File Number Information Technology Equipment, General Requirements for Safety E224736 Industrial Control Equipment E470721 SA1508106S 001 + SA1508106S 002 Information Technology Equipment - General Requirments for Safety EAC Standard UL60950-1, 2nd Edition, 2014 CSA C22.2 No. 60950-1-07, 2nd Edition, 2014 UL508, 17th Edition, 2013 CSA C22.2 No. 107.1-01, 3rd Edition, 2011 IEC60950-1, 2nd Edition 2005, +AM1:2009 + AM2:2013 EN60950-1:2006, + A11:2009 + A1:2010 + A12:2011 + A2:2013 RU-AT.37.02367 RoHs2+ TP TC 004/2011 RoHs 2011/65/EU EMC Compliance Report / Condition Information technology equipment - Radio disturbance characteristics Limits and methods of measurement Standard / Criterion EN55022, Class B, 2010 Information technology equipment - Immunity characteristics - Limits and methods of measurement EN55024, Class B, 2010 Limitations on the amount of electromagnetic intererence allowed from digital and electronic devices 47 CFR FCC Part 15, Subpart B: 2014 Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz ANSI C63.4: 2014 continued on next page www.recom-power.com REV.: 3/2018 PDR-5 REDIN120 AC/DC Converter Series Specifications (measured @ Ta= 25C, rated Vin, rated load and after warm up) EMC Compliance Report / Condition ESD Electrostatic discharge immunity test Air 8kV, Contact 4kV EN61000-4-2, Criteria B, 2009 3V/m EN61000-4-3, Criteria A, 2006 Radiated, radio-frequency, electromagnetic field immunity test Fast Transient and Burst Immunity Surge Immunity Standard / Criterion AC Power Port: L+N+PE 1kV EN61000-4-4, Criteria B, 2012 AC Power Port L-N 1kV, L-PE + N-PE 2kV EN61000-4-5, Criteria B, 2014 AC Power Port 3V EN61000-4-6, Criteria A, 2014 50Hz, 1A/m EN61000-4-8, Criteria A, 2010 Voltage Dips >95% Voltage Dips 30% Voltage Interruptions >95% EN61000-4-11, Criteria B, 2004 EN61000-4-11, Criteria C, 2004 EN61000-4-11, Criteria C, 2004 Immunity to conducted disturbances, induced by radio-frequency fields Power Magnetic Field Immunity Voltage Dips and Interruptions Limits of Harmonic Current Emissions EN61000-3-2, Criteria A, 2014 Voltage Fluctuations & Flicker EN61000-3-3, Clause 5: 2013 DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Material case cover aluminium nickel plated steel Dimension (LxWxH) without mounting clip 114.5 x 33.0 x 124.4mm Weight 590g typ. Dimension Drawing (mm) 42.2 10.3 27.2 DC OK +V -V Vadj. 28.4 56.9 55.0 124.4 127.9 8.5 DC OK LED Parallel Use Single Use N L PE 33.0 114.5 43.0 124.0 continued on next page www.recom-power.com REV.: 3/2018 PDR-6 56.9 REDIN120 AC/DC Converter Series 43.0 114.5 Specifications (measured @ Ta= 25C, rated Vin, rated load and after warm up) 124.0 10.6 41.5 46.1 Terminals and Wiring Type Screw Connector Solid Wire 2.5-6mm2 Stranded Wire 2.5-4mm2 American Wire Gauge (AWG) AWG10-16 Wire Stripping Length 8mm Screwdriver (slotted / cross) 3.5mm Recommended tightening torque 0.5Nm-0.8Nm Tolerance: X.X 0.5mm X.XX 0.25mm INSTALLATION and APPLICATION Mounting Instruction Mounting Releasing 1 Vadj. Vadj. DC OK LED Parallel Use Single Use DC OK LED Parallel Use Single Use 2 Click" 2 1 continued on next page www.recom-power.com REV.: 3/2018 PDR-7 REDIN120 AC/DC Converter Series Specifications (measured @ Ta= 25C, rated Vin, rated load and after warm up) INSTALLATION and APPLICATION Mounting Multiple Power Supplies Vadj. Vadj. Vadj. DC OK LED DC OK LED DC OK LED Parallel Use Single Use Parallel Use Single Use Parallel Use Single Use 15mm 15mm leave 15mm gap between supplies 15mm Minimum Abstand PARALLEL OPERATION L1 L2 L3 N PE - ~ ~ ~ + L N PE ~ +V -V DC OK + - ~ +V -V DC OK ~ +V -V DC OK + + - - Load + - DC OK Single Operation: 1) Make sure that the front panel switch is set to "single Use." 2) The output voltage can be increased by trim pot to compensate any cable losses. Parallel Operation: 1) Make sure that the front panel switch is set to "single Use" on each power supply. 2) Adjust each power supply to the exact same output voltage with same load and cooling conditions. 3) Set the front panel switches to "Parallel Use." Use the same wire length for each power supply (star connection) and energize all units at the same time to avoid triggering overload protection. Derate the maximum output power to 90% of nominal ratings. For operation with more than three power supplies in parallel or series operation, please contact RECOM technical support for advice. continued on next page www.recom-power.com REV.: 3/2018 PDR-8 REDIN120 AC/DC Converter Series Specifications (measured @ Ta= 25C, rated Vin, rated load and after warm up) BLOCK DIAGRAMM L N T5A Input Filter Power Stage PE +V Output Filter -V DC Relay OTP ShutDown Protection OCP Limit OVP ShutDown OK LED Output Voltage Regulation Vadj. Single / Parallel PACKAGKING INFORMATION Parameter Type Packaging Dimension (LxWxH) cardboard box Packaging Quantity cardboard box Storage Temperature Range Value 140.0 x 50.0 x 142.0mm 1pcs. -40C to +85C Storage Humidity 5% - 95% RH The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 3/2018 PDR-9