Solid State Relay G3NA New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output. * AC Output Relays with 75-A and 90-A output added. * All models feature a uniform mounting pitch. * Built-in varistor effectively absorbs external surges. (except G3NA-D210B) * Operation indicator enables monitoring operation. * Protective cover for greater safety. * Standard models certified by UL and CSA and -UTU models by VDE (TUV). (except G3NA-410B, G3NA-420B, and G3NA-440B(-2)) Ordering Information To Order: Select the part number and add the desired rated input voltage, (e.g., G3NA-240B-100 to 120 VAC) . Isolation Phototriac Zero cross function Yes Photocoupler Indicator Yes Rated output load (applicable output load) 5 A at 24 to 240 VAC* (19 to 264 VAC) Rated input voltage 5 to 24 VDC Model G3NA-205B 100 to 120 VAC 200 to 240 VAC Phototriac Photocoupler 10 A at 24 to 240 VAC* (19 to 264 VAC) 5 to 24 VDC G3NA-210B 100 to 120 VAC 200 to 240 VAC Phototriac Photocoupler 20 A at 24 to 240 VAC* (19 to 264 VAC) 5 to 24 VDC G3NA-220B 100 to 120 VAC 200 to 240 VAC 25 A at 24 to 240 VAC* (19 to 264 VAC) 5 to 24 VDC G3NA-225B 100 to 120 VAC 200 to 240 VAC 25 A at 200 to 480 VAC* (180 to 528 VAC) 5 to 24 VDC G3NA-425B 100 to 240 VAC (Table continued on next page.) Solid State Relay G3NA 469 Isolation Phototriac Zero cross function Yes Indicator Yes Rated output load (applicable output load) 40 A at 24 to 240 VAC* (19 to 264 VAC) Photocoupler Rated input voltage 5 to 24 VDC Model G3NA-240B 100 to 120 VAC 200 to 240 VAC Phototriac Photocoupler Phototriac Photocoupler -- Yes 75 A at 24 to 240 VAC* (19 to 264 VAC) 5 to 24 VDC 100 to 240 VAC 90 A at 24 to 240 VAC* (19 to 264 VAC) 100 to 240 VAC 5 to 24 VDC G3NA-275B-UTU-2 G3NA-290B-UTU-2 10 A at 5 to 200 VDC (4 to 220 VDC) 5 to 24 VDC G3NA-D210B 10 A at 200 to 480 VAC* (180 to 528 VAC) 5 to 24 VDC 20 A at 200 to 480 VAC* (180 to 528 VAC) 5 to 24 VDC 40 A at 200 to 480 VAC* (180 to 528 VAC) 5 to 24 VDC 50 A at 200 to 480 VAC* (180 to 528 VAC) 5 to 24 VDC G3NA-450B-2 75 A at 200 to 480 VAC* (180 to 528 VAC) 5 to 24 VDC G3NA-475B-UTU-2 90 A at 200 to 480 VAC* (180 to 528 VAC) 5 to 24 VDC 100 to 240 VAC G3NA-410B 100 to 240 VAC G3NA-420B 100 to 240 VAC G3NA-440B-2 100 to 240 VAC 100 to 240 VAC G3NA-490B-UTU-2 100 to 240 VAC *Loss time increases under 75 VAC. Note: 1. Standard models are certified by UL and CSA. 2. When ordering a UL, CSA and TUV-approved model, add "-UTU" to the model number as shown below: Example: G3NA-210B-UTU. 3. The applicable load is the value for when the SSR is used with silicon grease applied to the specified heat sink. The applicable load depends upon the ambient temperature. Refer to Load Current vs. Ambient Temperature charts in the Engineering Data section. Accessories Heat Sinks Types Standard mount Track mount Applicable solid-state relays Model G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-220B, G3NA-410B, G3NA-420B Y92B-A100 G3NA-225B, G3NA-240B-2, G3NA-425B, G3NA-440B-2 Y92B-A150N G3NA-440B-2 Y92B-A250 G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-410B Y92B-N50 G3NA-220B, G3NA-420B Y92B-N100 G3NA-225B, G3NA-240B, G3NA-425B, G3NA-440B-2 Y92B-N150 G3NA-450B-2 Y92B-P250 G3NA-275B-UTU-2, G3NA-290B-UTU-2, G3NA-475B-UTU-2, G3NA-490B-UTU-2 Y92B-P250NF Mounting Track and Accessories Description Mounting bracket for G3NA-240B and G3NA-440B-2. Changes pitch to 56 mm (2.21 in.) from 47.5 mm (1.73 in.), the same pitch as G3N-240B. Model R99-11 DIN Rail Track, 50 cm (1.64 feet) length; use with Y92B-N heat sinks PFP-50N DIN Rail Track, 1 m (3.28 feet) length; use with Y92B-N heat sinks PFP-100N Spacer PFP-S End cap PFP-M One-touch mounting plate R99-12 FOR G3NA 470 Solid State Relay G3NA Specifications Input Ratings (Ambient temperature: 25C [77F]) Type G3NA-2B Rated voltage Operating voltage range Impedance (See note 1) Voltage level Must operate voltage 4 VDC max. Must release voltage 1 VDC min. 5 to 24 VDC 4 to 32 VDC 7 mA max. (see note 2) 100 to 120 VAC 75 to 132 VAC 36 k 20% (see note 4) 75 VAC max. (see note 3) 20 VAC min. (see note 3) 200 to 240 VAC 150 to 264 VAC 72 k 20% 150 VAC max. (see note 3) 40 VAC min. (see notes 3 and 5) G3NA-4B 5 to 24 VDC 4 to 32 VDC 5 mA max. (see note 2) 4 VDC max. 1 VDC min. G3NA-D210B 100 to 240 VAC 75 to 264 VAC 72 k 20% 75 VAC max. 20 VAC min. G3NA-275B-UTU-2 G3NA-290B-UTU-2 5 to 24 VDC 4 to 32 VDC 15 mA max. (see note 6) 4 VDC max. 1 VDC min. G3NA-475B-UTU-2 G3NA-490B-UTU-2 100 to 240 VAC 75 to 264 VAC 72 k 20% 75 VAC max. 20 VAC min. Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC, the input impedance is measured at 120 VAC). 2. With constant current input circuit system, the impedance for the G3NA-2B-UTU is 15mA max. 3. Refer to the "Characteristic Data" for further details. 4. The G3NA-240B(-UTU) is 72k 20% 5. The G3NA-240B(-UTU) is 20 VAC min. 6. The impediance for G3NA-475B-UTU-2 and G3NA-490B-UTU-2 is 7 mA max. Output Ratings Type Applicable load Rated load voltage Load voltage range Load current VDRM, VCEO (Ref. Value) Surge current With heat sink* Without heat sink G3NA-205B 24 to 240 VAC 19 to 264 VAC 0.1 to 5 A (at 40C) 0.1 to 3 A (at 40C) 60 A (60 Hz, 1 cycle) 600V (VDRM) G3NA-210B 24 to 240 VAC 19 to 264 VAC 0.1 to 10 A (at 40C) 0.1 to 4 A (at 40C) 150 A (60 Hz, 1 cycle) 600V (VDRM) G3NA-410B 200 to 480 VAC 180 to 528 VAC 0.2 to 10 A (at 40C) 0.2 to 4 A (at 40C) G3NA-220B 24 to 240 VAC 19 to 264 VAC 0.1 to 20 A (at 40C) 0.1 to 4 A (at 40C) G3NA-420B 200 to 480 VAC 180 to 528 VAC 0.2 to 20 A (at 40C) 0.2 to 4 A (at 40C) G3NA-240B 24 to 240 VAC 19 to 264 VAC 0.1 to 40 A (at 40C) 0.1 to 6 A (at 40C) G3NA-440B-2 200 to 480 VAC 180 to 528 VAC 0.2 to 40 A (at 40C) 0.2 to 6 A (at 40C) G3NA-450B 200 to 480 VAC 180 to 528 VAC 0.2 to 50 A (at 40C) 0.2 to 6 A (at 40C) G3NA-D210B 5 to 200 VDC 1,200V (VDRM) 220 A (60 Hz, 1 cycle) 600V (VDRM) 1,200V (VDRM) 440 A (60 Hz, 1 cycle) 600V (VDRM) 1,200V (VDRM) 400V (VCEO) 4 to 220 VDC 0.1 to 10 A (at 40C) 0.1 to 4 A (at 40C) 20 A (10 ms) G3NA-275B-UTU-2 24 to 240 VAC 19 to 264 VAC 1 to 75 A (at 40C) 1 to 7 A (at 40C) 800 A (60 Hz, 1 cycle) 600V (VDRM) G3NA-475B-UTU-2 200 to 480 VAC 180 to 528 VAC 1 to 75 A (at 40C) 1 to 7 A (at 40C) 800 A (60 Hz, 1 cycle) 1,200V (VDRM) G3NA-290B-UTU-2 24 to 240 VAC 19 to 264 VAC 1 to 90 A (at 40C) 1 to 7 A (at 40C) 1,000 A (60 Hz, 1 cycle) 600V (VDRM) G3NA-490B-UTU-2 200 to 480 VAC 180 to 528 VAC 1 to 90 A (at 40C) 1 to 7 A (at 40C) 1,000 A (60 Hz, 1 cycle) 1,200V (VDRM) *When the appropriate size OMRON heat sink is used. Note: The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature charts in the Engineering Data section. Solid State Relay G3NA 471 Characteristics Type Operate time Release time G3NA-205B, G3NA-240B G3NA-410B, -210B, -220B, -420B, -425B, -225B -440B-2, -450B-2 G3NA275BUTU-2 G3NA290BUTU-2 G3NA475BUTU-2 G3NA490BUTU-2 DC input 1/2 of load power source cycle + 1 ms max. 1 ms max. 1/2 of load power source cycle + 1 ms max. AC input 1 1/2 of load power source cycle + 1 ms max. 30 ms max. 3/2 of load power source cycle + 1 ms max. DC input 1/2 of load power source cycle + 1 ms max. 5 ms max. 1/2 of load power source cycle + 1 ms max. AC input 1 1/2 of load power source cycle + 1 ms max. 30 ms max. 3/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current 5 mA max. at 100 VAC 10 mA max. at 200 VAC Insulation resistance 100 M min at 500 VDC Dielectric strength 1.6 V (RMS) max. 1.8 V (RMS max.) 1.5 V max. 10 mA max. at 200 VAC 20 mA max. at 400 VAC 2,500 VAC, 50/60 Hz for 1 minute Vibration Malfunction 10 to 55 Hz, 1.5 mm double amplitude Shock Malfunction 1,000 m/s2 (approx. 100G) Ambient temperature Operating -30 to 80C with no icing or condensation Storage 45% to 85% RH Weight Approx. 60 g Note: Data shown are of initial value. Solid State Relay 5 mA max. at 200 VDC 1.6 V (RMS) max. 1.8 V (RMS) max. 5 mA max. at 100 VAC 10 mA max. at 200 VAC 10 mA max. at 200 VDC 20 mA max. at 400 VAC 4,000 VAC, 50/60 Hz for 1 min. -30 to 100C with no icing or condensation Ambient operating humidity 472 G3NAD210B G3NA Approx. 70 g Approx. 80 g Approx. 70 g Approx. 120 g Engineering Data Load Current vs. Ambient Temperature G3NA-205B G3NA-210B/410B G3NA-220B/420B With standard heat sink (Y92B-A100 or Y92BN50) or aluminum plate measuring 75 mm x 75 mm x t3.2 mm (W x H x t) Without heat sink Load current (A) Load current (A) Load current (A) 20 16 10 With standard heat sink (Y92B-A100 or Y92BN50) or aluminum plate 8 measuring 150 mm x 150 mm x t3.2 mm (W x H x t) 6 5 With iron plate measuring 100 x 100 x t0.8 (W x H x t) 4 Without heat sink With standard heat sink (Y92B-A100 or Y92BN100) or aluminum plate measuring 200 mm x 200 mm x t3.2 mm (W x H x t) With iron plate measuring 100 x 100 x t0.8 (W x H x t) 2 Without heat sink 0 G3NA-240B G3NA-440B Load current (A) 20 With iron plate measuring 12 100 x 100 x t0.8 (W x H x t) 10 Without heat sink 6 4 2 0 -30-20 0 20 40 60 80 30 With standard heat sink (Y92B-A150N or Y92B-N150) 20 With iron plate measuring 12 100 x 100 x t0.8 (W x H x t) 10 Without heat sink 6 4 2 0 -30-20 0 20 40 60 100 Ambient temperature (C) G3NA-290B-UTU-2 G3NA-490B-UTU-2 80 75 70 100 30 20 With iron plate measuring 100 x 100 x t0.8 (W x H x t) 12 10 7 Without heat sink 4A 20 -30-20 0 20 40 60 70 80 100 Ambient temperature (C) 80 Load current (A) Using the Y92B-P250NF 40 30 20 10 6 80 Without heat sink 0 -30 -20 100 0 20 40 60 80 100 Ambient temperature (C) G3NA-D210B 20 90 0.6C/W with Heat Sink 50 With standard heat sink (Y92B-P250) Ambient temperature (C) G3NA-275B-UTU-2 G3NA-475B-UTU-2 60 50 0.3C/W with Heat Sink 70 60 50 Using the Y92B-P250NF 40 35 30 iron plate measuring 20 With 100 x 100 x t0.8 (W x H x t) 12 7 4A Without heat sink 20 -30 -20 0 20 40 60 70 80 100 Ambient temperature (C) 10 Load current (A) Load current (A) With standard heat sink (Y92B-A150N or Y92B-N150) Load current (A) 40 40 Load current (A) With Y92B-A250 or heat sink with a radiation efficiency of 1C/W. 45 45 40 G3NA-450B-2 60 50 50 30 Ambient temperature (C) Ambient temperature (C) Ambient temperature (C) With standard heat sink (Y92B-A100 or Y92B-N50) or aluminum plate measuring 150 mm x 150 mm x t3.2 mm (W x H x t) 6 5 With iron plate measuring 100 x 100 x t0.8 (W x H x t) 4 Without heat sink 2 0 -30 -20 0 20 40 60 80 100 Ambient temperature (C) Note: The ambient operating temperature of the Y92B-P250NF is -30 to 70C. Be sure the operating temperature is within this range. Solid State Relay G3NA 473 One Cycle Surge Current The values shown by the solid line are for non-repetitive inrush currents. Keep the inrush current below the values shown by the dotted line if it occurs repetitively. 40 150 100 20 0 10 30 50 100 200 500 1,000 0 5,000 10 30 50 100 200 500 1,000 400 300 100 200 50 100 0 5,000 30 50 100 200 500 1,000 5,000 10 30 50 100 200 500 1,000 5,000 Energized time (ms) G3NA-290B-UTU-2 G3NA-490B-UTU-2 Inrush current (A peak) 30 28 0 10 Energized time (ms) G3NA-275B-UTU-2 G3NA-475B-UTU-2 Inrush current (A peak) Inrush current (A peak) 150 Energized time (ms) G3NA-D210B 900 800 700 600 500 400 300 1,200 1,000 800 600 400 200 200 100 0 10 20 30 50 70 100 200 300 500 0 10 1,000 2,000 30 50 100 Energized time (ms) Temperature Characteristics (for Must Operate Voltage and Must Release Voltage) 1,000 Heat sink area (cm2) 0 3,000 2,000 Ambient temperature 80C -20 300 200 Aluminum plate 3.2 mm thick 30 20 -40 20 40 60 80 50 100 300 1,000 Energized time (ms) Ambient temperature 40C 1,000 700 500 100 70 50 0 30 G3NA-220B 20 -20 10 Heat Sink Area vs. Load Current 40 -30 300 Energized time (ms) G3NA-2B AC input Variation rate (%) 200 50 Energized time (ms) 26 24 22 20 18 16 14 12 10 8 6 4 2 0 G3NA-240B G3NA-440B-2/-450B-2 Inrush current (A peak) Inrush current (A peak) Inrush current (A peak) 60 G3NA-220B G3NA-420B Inrush current (A peak) G3NA-210B G3NA-410B G3NA-205B 100 Ambient temperature (C) 0 2 4 6 8 10 12 14 16 18 20 22 24 Load current (A) Thermal Resistance Rth (Back of Junction SSR) (Examples) Model Note: The heat sink area refers to the combined area of the sides of the heat sink that radiate heat. For example, when a current of 18 A is allowed to flow through the SSR at 40C, the graph shows that the heat sink area is about 450 cm2. Therefore, if the heat sink is square, one side of the heat sink must be 15 cm ( 450 (cm2)/2 ) or longer. Thermal Resistance Rth of Heat Sinks (Examples) Rth (C/W) Model Rth (C/W) G3NA-205B 3.22 Y92B-N50 2.8 G3NA-210B 2.62 Y92B-N100 1.63 G3NA-220B 1.99 Y92B-N150 1.38 G3NA-240B-2 0.45 Y92B-A100 1.63 G3NA-275B-UTU-2 G3NA-475B-UTU-2 G3NA-290B-UTU-2 G3NA-490B-UTU-2 0.45 Y92B-A150N 1.37 Y92B-A250 1.00 Y92B-P250NF 0.46 G3NA-D210B 2.62 474 Solid State Relay G3NA Note: When using a commercially available heat sink, use one with a thermal resistance equal to or less that the OMRON Heat Sink. Dimensions Relays Note: All units are in millimeters unless otherwise indicated. G3NA-205B, G3NA-210B, G3NA-220B, G3NA-410B, G3NA-420B 11.9 Four, M4 x 8 4.5 dia. screws Mounting Holes Two, 4.3-dia. or M4 holes Terminal Arrangement/ Internal Connections (Top View) Load Load power supply 58 max. 47.5 44 Output 1 2 (-) 4 (+) 3 47.60.2 4.5 25 43 max. Operating indicator 15.8 *18.9 25 max. *28 max. 27 max. *30 max. Input *Size for G3NA-410B and G3NA-420B. G3NA-240B, G3NA-440B-2 11.9 Mounting Holes 4.5 dia. Two, M5 x 12 screws Two, 4.3-dia. or M4 holes Terminal Arrangement/ Internal Connections (Top View) Load Load power supply 58 min. 47.5 44 Output 47.60.2 Operating indicator 4.5 25 Two, M4x8 43 max. 15.8 *18.9 25 max. *28 max. 27 max. *30 max. 1 2 (-) 4 (+) 3 Input *Size for G3NA-240B and G3NA-440B-2 G3NA-D210B Note: The load can be connected to either the positive or negative side. 11.9 Four, M4 x 8 4.5 dia. screws Mounting Holes Terminal Arrangement/ Internal Connections (Top View) Two, 4.3-dia. or M4 holes Load 58 max. 47.5 44 Load power supply Output 1 - 47.60.2 Operating indicator 4.5 25 43 max. 2 + (-) 4 15.8 25 max. 27 max. (+) 3 Input Note: When connecting the load, either the positive or negative side of the load terminals can be connected. G3NA-275B-UTU-2, G3NA-475B-UTU-2, G3NA-290B-UTU-2, G3NA-490B-UTU-2 4.5 dia. 12 Two, M5 x 12 screws Mounting Holes Two, 4.3-dia. or M4 holes Terminal Arrangement/ Internal Connections (Top View) Load 58 max.47.5 44 Output 4.5 8.2 25 43 max. Operating indicator Two, M4 x 8 screws 1 47.60.2 16.8 26 max. 28 max. 2 *18.9 (-) 4 *28 max. *30 max. Input Load power supply (+) 3 *Size for G3NA-@@@B-UTU-2. Solid State Relay G3NA 475 Options (Order Separately) To mount the Relay to DIN Track, first mount it to the One-touch Mounting Plate and then attach it to the DIN Track as shown in the diagram. One-touch Mounting Plate The One-touch Mounting Plate is used to mount the GN3A to a DIN Track. R99-12 FOR G3NA (for the G3NA and G3NE) Two, M4 mounting holes for the G3NA To remove the Relay from the DIN Track, pull down on the tab with a screwdriver in the direction of the arrow. 30 44 Two, M4 mounting holes for the G3NE * When a Relay is mounted to DIN Track, use it within the rating for a Relay without a heat sink. * Use the following DIN Tracks: PFP-100N or PFP-100N2. Mounting Bracket R99-11 (for the G3NA-240B, G3NA-440B) Use Mounting Bracket R99-11 so that the G3NA-240B/-440B can be mounted with the same pitch as that of the G3N-240B. 16 8 5 12.5 56 21 4 4.6 Heat Sinks Y92B-N50 Heat Sink (for the G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-410B, G3NE-210T(L)) For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs). The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions. Mounting Holes 4.6 dia. Two, 4.4-dia. or M4 holes Two, M3 holes Two, 3.2-dia. holes Two, M4 holes 44 max. 30 35 30.50.3 47.6 77 max. 900.3 100 max. 5.6 5 47 max. 6 4.5 900.4 51 max. 350.2 Weight: approx. 200 g 476 Solid State Relay G3NA Y92B-N100 Heat Sink (for the G3NA-220B, G3NA-420B, G3NE-220T(L)) For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs). The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions. Mounting Holes Two, M4 4.6 dia. Two, M3 holes Two, 3.2-dia. holes holes Two, 4.4-dia. or M4 holes 71 max. 30 35 30.50.3 75 max. 900.4 47.6 77 max. 900.3 5.6 28 5 100 max. 13 4.5 100 max. 350.2 Weight: approx. 400 g Y92B-N150 Heat Sink (for the G3NA-240B, G3NA-440B-2) For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs). The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions. Mounting Holes Two, 3.2-dia. holes 47.6 Two, 4.4-dia. or M4 holes Three, M4 holes 4.6 dia. 35 100 max. 30 560.3 77 max. 900.3 100 max. 104 max. 28 5.6 5 100 max. 13 4.5 Weight: approx. 560 g Y92B-P250NF Heat Sink (for the G3NA-275B-UTU-2, G3NA-475B-UTU-2, G3NA-290B-UTU-2, G3NA-490B-UTU-2) The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions. Observe the precautions given in Mounting Method under Precautions for Correct Use. Mounting Holes Fan power supply, 200 VAC 50/60 Hz 172 max. 160 max. 120 1300.3 M4 80 max. 64 640.3 133.4 120 max. 105 110max. Two, 4.6-dia. holes 47.6 Two, M4 holes Thermostat NC contact, 90C Two, 4.5-dia. or M4 holes Weight: approx. 2.5 kg Solid State Relay G3NA 477 Y92B-P250 Two, M4 Depth 10 Four, M4 Mounting Holes Four, 4.5 dia. or M4 190.5 max. 47.6 Four, R2.5 130.5 max. 70 max. 900.1 R2.2 Y92B-A250 Heat Sink (for the G3NA-440B-2) Three, M4 holes Three, M4 holes 900.1 Two, M4 holes Y92B-A150N Heat Sink (for the G3NA-240B, G3NA-440B-2) 47.6 900.1 Y92B-A100 Heat Sink (for the G3NA-205B, G3NA-210B, G3NA-220B, G3NA-410B, G3NA-420B, G3NA-D210B) R2.2 80.5 max. 1.5 47.6 102 max. 9.6 2 47.6 500.1 100 max. 500.1 560.5 150 max. Weight: approx. 210 g Weight: approx. 310 g 500.1 560.5 250 max. 30 45.5 max. 1.5 Weight: approx. 510 g Mounting Holes Y92B-A100 Y92B-A150 Y92B-A250 Four, 4.3-dia. or M4 holes For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs). The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions. 478 Solid State Relay G3NA Approvals UL Recognized (File No. E64562) / CSA Certified (File No. LR35535) - - Ambient Temp. = 40C SSR type Input voltage Load type Contact ratings Without heat sink G3NA-205B G3NA-210B 5 to 24 VDC 100 to 120 VAC 200 to 240 VAC General use/Tungsten 3 A, 240 VAC With heat sink (see note 1) 5 A, 240 VAC Motor 2.5 FLA, 15 LRA, 240 VAC 2.5 FLA, 15 LRA, 240 VAC General use/Tungsten 4 A, 240 VAC 10 A, 240 VAC Motor 2.5 FLA, 15 LRA, 240 VAC 5 FLA, 30 LRA, 240 VAC G3NA-220B General use/Tungsten 4 A, 240 VAC 20 A, 240 VAC Motor 2.5 FLA, 15 LRA, 240 VAC 10 FLA, 60 LRA, 240 VAC G3NA-225B General use/Tungsten 4 A, 240 VAC 25 A, 240 VAC Motor 2.5 FLA, 15 LRA, 240 VAC 12 FLA, 72 LRA, 240 VAC G3NA-240B General use/Tungsten 6 A, 240 VAC 40 A, 240 VAC 20 FLA, 120 LRA, 240 VAC Motor 5 FLA, 30 LRA, 240 VAC General use/Tungsten 4 A, 480 VAC 10 A, 480 VAC Motor 2.5 FLA, 15 LRA, 480 VAC 5 FLA, 30 LRA, 480 VAC General use/Tungsten 4 A, 480 VAC 20 A, 480 VAC Motor 2.5 FLA, 15 LRA, 480 VAC 10 FLA, 60 LRA, 480 VAC G3NA-425B General use/Tungsten 4 A, 480 VAC 25 A, 480 VAC Motor 2.5 FLA, 15 LRA, 480 VAC 12 FLA, 72 LRA, 480 VAC G3NA-440B General use/Tungsten 6 A, 480 VAC 40 A, 480 VAC Motor 5 FLA, 30 LRA, 480 VAC 20 FLA, 120 LRA, 480 VAC G3NA-450B General use/Tungsten 6 A, 480 VAC 50 A, 480 VAC Motor 5 FLA, 30 LRA, 480 VAC 24 FLA, 144 LRA, 480 VAC G3NA-D210B General use 4 A, 200 VDC 10 A, 200 VDC G3NA-410B G3NA-420B 5 to 24 VDC 100 to 240 VAC Note: 1. When used with the proper OMRON heat sink part number or an appropriately dimensioned equivalent. 2. The rated values approved by each of the safety standards (e.g., UL, CSA, and TUV) may be different from the performance characteristics individually defined in this catalog. 3. In the interest of product improvement, specifications are subject to change. Solid State Relay G3NA 479 Safety Precautions ! Caution Touching the charged section may occasionally cause minor electric shock. Do not touch the G3NA terminal section (the charged section) when the power supply is ON. Be sure to attach the cover before use. ! Caution The G3NA and heat sink will be hot and may occasionally cause minor burns. Do not touch the G3NA or the heat sink either while the power supply is ON, or immediately after the power is turned OFF. 3. Wire the G3NA and tighten screws correctly, observing the following precautions Heat generated by a terminal error may occasionally result in fire damage. Do not operate if the screws on the output terminal are loose. * Abnormal heat generated by wires may occasionally result in fire damage. Use wires suitable for the load current. * Abnormal heat generated by terminals may occasionally result in fire damage. Do not operate if the screws on the output terminal are loose. Tightening Torque ! Caution The internal snubber circuit is charged and may occasionally cause minor electric shock. Do not touch the G3NA's main circuit terminals immediately after the power is turned OFF. ! Caution Be sure to conduct wiring with the power supply turned OFF, and always attach the terminal cover after completing wiring. Touching the terminals when they are charged may occasionally result in minor electric shock. Screw size Tightening torque M4 1.2 N*m M5 2.0 N*m * Abnormal heat generated by terminals may occasionally result in fire damage. When tightening terminal screws, be sure that no non-conductive foreign matter is caught in screw. * For GN3A Relays of 40 A or higher, use crimp terminals of an appropriate size for the wire diameter for M5 terminals. * Do not use any wires with damaged sheaths. These may cause electric shock or leakage. ! Caution Do not apply a short-circuit to the load side of the G3NA. The G3NA may rupture. To protect against short-circuit accidents, install a protective device, such as a quickburning fuse, on the power supply line. Precautions for Safe Use Although OMRON continuously strives to improve the quality and reliability of our relays, the G3NA contains semiconductors, which are generally prone to occasional malfunction and failure. Maintaining safety is particularly difficult if a relay is used outside of its ratings. Always use the G3NA within the rated values. When using the G3NA, always design the system to ensure safety and prevent human accidents, fires, and social damage even in the event of G3NA failure, including system redundancy, measures to prevent fires from spreading, and designs to prevent malfunction. * Do not place wiring in the same conduit or duct as high-voltage lines. Induction may cause malfunction or damage. * Use wires of an appropriate length, otherwise malfunction and damage may result due to induction. * Mount the DIN Track securely. Otherwise, the DIN Track may fall. * Be sure that the G3NA clicks into place when mounting it to DIN Track. The G3NA may fall if it is not mounted correctly. * Do not mount the G3NA when your hands are oily or dirty, e.g., with metal powder. These may cause G3NA failure. * Tighten the G3NA screws securely. Tightening torque: 0.78 to 0.98 N*m * Tighten the heat sink screws securely. Tightening torque: 0.98 to 1.47 N*m * Mount the G3NA in the specified orientation. If the G3NA is mounted in any other orientation, abnormal heat generation may cause output elements to short or may cause burning. 4. Preventing Overheating When using the High-capacity Heat Sink (Y92B-P250NF), always use a thermostat or other method to protect from overheating in the event that the fan stops. 5. Do Not Touch Fan Blades When the fan is operating, do not touch the fan blades with any part of your body or allow foreign matter to come into contact with the blades. Always attach the enclosed finger guard when using the G3NA. 6. Operating Conditions * Only use the G3NA with loads that are within the rated values. Using the G3NA with loads outside the rated values may result in malfunction, damage, or burning. * Do not use the G3NA if the heat sink fins are bent, e.g., as the result of dropping the G3NA. Heat dissipation characteristics will be reduced, possibly causing G3NA failure. * Use a power supply within the rated frequency range. Using a power supply outside the rated frequency range may result in malfunction, damage, or burning. * Apply a thin layer of Momentive Performance Material's YG6260 or Shin-Etsu Chemical's G747, or a similar product to the heat sink before mounting. 7. Do not transport the G3NA under the following conditions. Failure or malfunction may occur. * Conditions under which the G3NA will be exposed to water 1. G3NA malfunction or fire damage may occasionally occur. Do not apply excessive voltage or current to the G3NA terminals. 2. Heat Dissipation * Do not obstruct the airflow to the G3NA or heat sink. Doing so may cause the output element to short, or cause fire damage. * Be sure to prevent the ambient temperature from rising due to the heat radiation of the G3NA. If the G3NA is mounted inside a panel, install a fan so that the interior of the panel is fully ventilated. * If a material with high thermal resistance, such as wood, is used, heat generated by the G3NA may occasionally cause fire or burning. When installing the G3NA directly into a control panel so that the panel can be used as a heat sink, use a panel material with low thermal resistance, such as aluminum or steel. * Use the specified heat sink or one with equivalent or better characteristics. 480 Solid State Relay G3NA * High temperatures or high humidity * Without proper packing !WARNING Minor Humon hazard by electric shock may occasionally occur. Heatsink must be connected to ground in the end product. Operating and Storage Locations Relationship between SSRs and Duct Height Do not use or store the G3NA in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. Incorrect Example Duct Mounting surface Mounting surface Vertical direction Airflow SSR Base Duct Duct Do not surround the SSR with ducts, otherwise the heat radiation of the SSR will be adversely affected. Countermeasure 2 50 mm max. (A height of no more than half the SSR's height is recommended.) Duct Mounting surface * Do not use or store in locations subject to direct sunlight. * Do not use in locations subject to ambient temperatures outside the range -20 to 60C. * Do not use in locations subject to relative humidity outside the range 45% to 85% or locations subject to condensation as the result of severe changes in temperature. * Do not store in locations subject to ambient temperatures outside the range -30 to 70C. * Do not use or store in locations subject to corrosive or flammable gases. * Do not use or store in locations subject to dust (especially iron dust) or salts. * Do not use or store in locations subject to shock or vibration. * Do not use or store in locations subject to exposure to water, oil, or chemicals. * Do not use or store in locations subject to high temperatures or high humidity. * Do not use or store in locations subject to salt damage. * Do not use or store in locations subject to rain or water drops. Countermeasure 1 Duct Use short ducts. If the ducts cannot be shortened, place the SSR on a metal base so that it is not surrounded by the ducts. Ventilation Outside the Control Panel Be aware of airflow Duct Ventilation outlet (axial fan) Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Before Actual Operation 1. The G3NA in operation may cause an unexpected accident. Therefore it is necessary to test the G3NA under the variety of conditions that are possible. As for the characteristics of the G3NA, it is necessary to consider differences in characteristics between individual SSRs. 2. Unless otherwise specified, the ratings in this catalog are tested values in a temperature range between 15C and 30C, a relative humidity range between 25% and 85%, and an atmospheric pressure range between 88 and 106 kPa (standard test conditions according to JIS C5442). It will be necessary to provide the above conditions as well as the load conditions if the user wants to confirm the ratings of specific G3NAs. Mounting Method SSR Mounting Pitch (Panel Mounting) Duct Air inlet If the air inlet or air outlet has a filter, clean the filter regularly to prevent it from clogging to ensure an efficient flow of air. Do not locate any objects around the air inlet or air outlet, otherwise the objects may obstruct the proper ventilation of the control panel. A heat exchanger, if used, should be located in front of the SSRs to ensure the efficiency of the heat exchanger. * Please reduce the ambient temperature of SSRs. The rated load current of an SSR is measured at an ambient temperature of 40C. * An SSR uses a semiconductor in the output element. This causes the temperature inside the control panel to increase due to heating resulting from the passage of electrical current through the load. To restrict heating, attach a fan to the ventilation outlet or air inlet of the control panel to ventilate the panel. This will reduce the ambient temperature of the SSRs and thus increase reliability. (Generally, each 10 C reduction in temperature will double the expected life.) Load current (A) 60 mm min. Required number of fans per SSR 5A 0.08 10 A 0.16 20 A 40 A 0.31 0.62 75 A 1.2 90 A 1.44 Example: For 10 SSRs with load currents of 10 A, 0.16 x 10 = 1.6 Vertical direction 30 mm min. 80 mm min. Thus, 2 fans would be required. Size of fans: 92 mm2, Air volume: 0.7 m3/min, Ambient temperature of control panel: 30 C If there are other instruments that generate heat in the control panel other than SSRs, additional ventilation will be required. Solid State Relay G3NA 481 High-capacity Heat Sink (Y92B-P250NF) Ratings and Characteristics of Highcapacity Heat Sink (Y92B-P250NF) Fan Ratings DIN-track Mounting * Assembled DIN Tracks are heavy. Mount the DIN Tracks securely. Be sure that the Heat Sink is securely locked to the DIN Track. * Attach End Plates (PFP-M, order separately) to both ends of the Units on the DIN Track to hold them in place. * To mount a Heat Sink to a DIN Track, press down at the point indicated by arrow 1 in the diagram and then press in the Heat Sink at the point indicated by arrow 2. Rated voltage 200 V Operating voltage 85% to 110% of rated voltage Frequency 50/60 Hz Rated current 0.061 A at 50 Hz (See note.) 0.052 A at 60 Hz Rated speed 2,600 r/min at 50 Hz (See note.) 3,050 r/min at 60 Hz Note: Average values. Thermostat Ratings Operating temperature Approx. 90C Contact ratings 3 A at 240 VAC or 24 VDC, resistive load Vertical Fan/Thermostat Characteristics Motor type Applicable DIN Track Mounting is possible on TE35-15Fe (IEC 60715) DIN tracks. DIN tracks from the following manufacturers can be used. Manufacturer Schneider Thickness: 1.5 mm Thickness: 2.3 mm AM1-DE2000 --- WAGO 210-114 or 210-197 210-118 PHOENIX N35/15 N35/15/15-2.3 Direct Mounting * Prepare mounting holes as shown in the diagram. Tightening torque: 0.98 to 1.47 N*m 640.3 1300.3 Four, 4.5 dia. or M4 holes * When mounting a Heat Sink directly, first remove the Fan Unit, then mount the Heat Sink by itself before attaching the Fan Unit again. (Remove the two screws shown in the following diagram.) Remove screws Fan Unit Heat Sink * First, temporarily mount the Heat Sink with the bottom two screws and then attach the top two screws with the mounting bracket sandwiched between the Heat Sink and mounting surface. Finally, tighten all four screws. Single-phase shading coil induction motor (2-pole, open type) Terminal type Terminals Insulation class IEC class B (130C) UL class A (105C) CSA class A (105C) Insulation 100 M min. (at 500 VDC) between all power resistance supply connections and uncharged metal parts. Insulation withstand 2,000 VAC (1 minute) between all power supvoltage ply connections and uncharged metal parts. Amb. operating temp. -30 to 70C (no icing) Amb. storage temp. -40 to 85C (no icing) Ambient humidity 25 to 85% Protection Impedance protection Materials Frame: Die-cast aluminum Blades: Glass polycarbonate Bearings Ball bearings Weight Approx. 300 g Compliant standards PSE, EN/IEC 60335 (CE marking compliant) Certified standards UL/CSA (pending) * Use a commercial power supply (50/60 Hz) for the Fan. * Be sure to turn OFF the power supply and wait for the blades to stop before inspecting the Fan. * High-precision ball bearings are used in the fan and these may be damaged if the Fan is dropped or otherwise subjected to shock. The life and characteristics of the Fan will be reduced if the bearings are damaged. Do not subject the Fan to shock. * The life of the Fan depends on the ambient temperature, As a guideline, the Fan life is 40,000 hours for continuous usage at 40C. * Be sure there are no objects near the air vents that would restrict air flow and no loose objects, such as electrical lines. * The Fan is an OMRON R87F-A4A-93HP (200 VAC) Fan. Use the same model of Fan for replacement. * The tightening torque of the mounting screw when replacing the Fan is 0.44 N*m. * Terminals equivalent to Faston #110 are used for the Fan power supply terminals. * Refer to the following table for the OMRON Fan power supply plug cables (order separately). Cable length UL certified Complies with Electrical Appliance and Material Safety Law (Japan) 1m R87F-PC R87F-PCJT 2m R87F-PC-20 R87F-PCJT-20 * Connect the ground screw hole on the fan to PE. 482 Solid State Relay G3NA Preventing Overheating with a High-capacity Heat Sink (Y92B-P250NF) * When the High-capacity Heat Sink is used, high-capacity switching at 75 A or 90 A requires forced cooling with a fan. Connect the Fan to a power supply according to its ratings specifications. * If the Fan stops due to a power supply error, due to foreign matter in the power supply connection, or due to aging, the Heat Sink will heat to high temperatures, possibly resulting in failure of the SSR or adverse affects on other devices. Implement an overheating prevention measure, such as turning OFF the load current, if the Heat Sink overheats. * A thermostat is provided to detect overheating. The thermostat uses a NC contact, i.e., the circuit will be opened for overheating. This thermostat can be used to stop the operation of the SSR. Implement an overheating prevention measure by using this signal to output an alarm or perform another response applicable to the system. Also, confirm that there is no problem with the overall system. * Do not connect the thermostat directly to the load power supply. Connect it to a contactor or other shutoff device connected above the SSR. * Terminals equivalent to Faston #187 are used for the thermostat terminals. * Do not place heat-dissipating silicon grease on the thermostat. * Do not solder the thermostat terminals. * The following diagram shows a protective circuit example. 2. DC-switching models Less than 3 m Load Input G3NA-UTU Output * The input cable must be less than 3 m. Loss Time The loss time will increase when the G3NA is used at a low applied voltage or current. Be sure that this does not cause any problems. Loss time Using DC Loads For a DC or L load, a diode should be connected in parallel the load to absorb the counter electromotive force of the load. Circuit breaker (contact side) Circuit breaker (coil side) Coil power supply Thermostat (NC contact) Load Y92B-P250NF G3NA Fuses Circuit breaker Ventilating a High-capacity Heat Sink (Y92B-P250NF) * Refer to Ventilation Outside the Control Panel. Operating Conditions * Do not apply currents exceeding the rated current otherwise, the temperature of the G3NA may rise excessively. * As protection against accidents due to short-circuiting, be sure to install protective devices, such as fuses and no-fuse breakers, on the power supply side. * Do not apply overvoltages to the input circuit or output circuit. Failure or burning may result. * Do not drop the G3NA or otherwise subject it to abnormal shock. Malfunction or failure may result. * Keep the cooling system running continuously during the ON/OFF operation of the SSR. This is to allow residual heat to dissipate while the SSR is OFF. (load current 75A, 90A models) EMC Directive Compliance (For -UTU type) EMC directives can be complied with under the following conditions. 1. AC-switching models * A capacitor must be connected to the input power supply. * A capacitor, varistor and toroidal core must be connected to the load power supply. * The input cable must be less than 3 m. Troidal core Load 3 m max. Load power supply SSR Load side Input side Input Load Input G3NA Output Connect a quick-break fuse in series with the load as a short-circuit protection measure. Use one of the fuses in the following table or one with equivalent or better characteristics. Recommended Fuses G3NA rated load current 5A 8A 10 A 15 A 20 A 25 A 30 A 40 A 45 A 50 A 75 A 80 A 100 A Fuse model Manufacturer 60LFF5 60LFF8 60LFF10 60LFF15 60LFF20 50SHA20 60PFF25 50SHA25 60PFF30 50SHA30 50SHA40 50SHA45 50SHA50 50SHA75 50SHA80 50SHB100 Applicable SSR Hinode Electric G3NA-205B Co., LTD. G3NA-210B G3NA-220B G3NA-240B G3NA-275B-UTU-2 G3NA-290B-UTU-2 Reverse Connection The output terminal side of the G3NA-D210B is connected to a builtin diode to protect the SSR from damage that may result from reverse connection. The SSR, however, cannot withstand one minute or more if the wires are connected in reverse. Therefore, pay the utmost attention not to make polarity mistakes on the load side. Recommended Capacitor : 0.05F, 500 VAC (Load) 0.1F, 250 VAC (Input) Recommended Varistor : 470 V, 1750 A Recommended Troidal core : NEC/TOKIN:ESD-R-25B or equivalent Solid State Relay G3NA 483 Precautions on Operating and Storage Environments 1. Operating Ambient Temperature 3. Vibration and Shock The rated value for the ambient operating temperature of the G3NA is for when there is no heat build-up. For this reason, under conditions where heat dissipation is not good due to poor ventilation, and where heat may build up easily, the actual temperature of the G3NA may exceed the rated value resulting in malfunction or burning. Do not subject the G3NA to excessive vibration or shock. Otherwise the G3NA may malfunction and internal components may be deformed or damaged, resulting in failure of the G3NA to operate. To prevent the G3NA from abnormal vibration, do not install the G3NA in locations or by means that will subject it to vibration from other devices, such as motors. When using the G3NA, design the system to allow heat dissipation sufficient to stay below the Load Current vs. Ambient Temperature characteristic curve. Note also that the ambient temperature of the G3NA may increase as a result of environmental conditions (e.g., climate or air-conditioning) and operating conditions (e.g., mounting in an airtight panel). 2. Transportation Do not allow the G3NA or the resin portion of the Fan's thermostat to come in contact with solvents, such as thinners or gasoline. Doing so will dissolve the markings on the G3NA. 5. Oil When transporting the G3NA, observe the following points. Not doing so may result in damage, malfunction, or deterioration of performance characteristics. * * * * 4. Solvents Do not allow the G3NA terminal cover to come in contact with oil. Doing so will cause the cover to crack and become cloudy. Do not drop the G3NA or subject it to severe vibration or shock. Do not transport the G3NA if it is wet. Do not transport the G3NA under high temperatures or humidity. Do not transport the G3NA without packing it properly. Operation 1. Leakage Current 2. Screw Tightening Torque A leakage current flows through a snubber circuit in the G3NA even when there is no power input. Therefore, always turn OFF the power to the input or load and check that it is safe before replacing or wiring the G3NA. Tighten the G3NA terminal screws properly. If the screws are not tight, the G3NA will be damaged by heat generated when the power is ON. Perform wiring using the specified tightening torque. 3. Handling Relays Varistor Trigger circuit Input circuit Switch element Snubber circuit Do not mount the G3NA when your hands are oily or dirty, e.g., with metal powder. These may cause G3NA failure. Leakage current 4. Do Not Drop Be careful not to drop a Relay or Heat Sink onto any part of your body while working. Injury may result. This is particularly true for the High-capacity Heat Sink (Y92B-P250NF), which weighs 2.5 kg. 484 Solid State Relay G3NA MEMO Solid State Relay G3NA All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 Global - http://www.omron.com USA - http://www.components.omron.com 847-882-2288 Cat. No. X301-E-1b Solid State Relay 09/11 G3NA Specifications subject to change without notice Printed in USA Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: Y92B-N50 Y92B-N100 Y92B-N150 Y92B-S08N