14 LA, 16 LA
Vishay Sfernice
Document Number: 54018
Revision 20-Dec-01 www.vishay.com
43
Precision Linear Transducers,
Designed for Mounting in Hydraulic or Pneumatic Cylinder,
Conductive Plastic Element (REC)
Theoretical electrical travel (TET = E) from 25mm to 2000mm in increments of 25mm
Independent linearity over TET ≤± 1%; ≤± 0.1%
on request ≤± 0.05% if E ≥100mm
≤± 0.025% if E ≥200mm
Actual electrical travel (AET) TET + 6mm ± 0.5
Total resistance RT150Ω/cm
Resistance tolerance at 20°C ± 20%
Repeatability ≤0.01%
Maximum power rating 0,05 W/cm at 70°C, 0 W at 125°C
Wiper current 1mA max. continuous, recommended: a few µA
Load impedance 1000 times RTminimum
I
nsulation resistance
> 1000MΩ500VDC
Dielectric strength > 300VRMS at 50Hz
Mechanical travel MT MT = TET
Body anodized aluminum
Rod internal diameter 14 LA: ø 16mm, 16 LA: ø 18mm
Support stainless steel
Operating force 1N typical
Sealing glass-sealing on electrical outputs
Electrical outputs connector
on request wires
Oil insulating mineral hydraulic
Pressure 300 bars continuous, 1000 bars accidentally
Wiper precious metal multifinger
FEATURES
• Large Range of Strokes from 25 to 2000mm
• High Accuracy
• Very Good Repeatability
• Continuous Resolution
• Easy Mounting
Those sensors are to be installed in the high pressure chamber of
cylinders and are equipped with glass-sealed electrical outputs
.
ELECTRICAL SPECIFICATIONS
Life 40 million of cycles
Temperature limits – 20°C to + 80°C
Speed at 20°C 1.5m/s max
PERFORMANCE