Surface Mounting Relay G6K Surface Mounting Relay with the World's Smallest Mounting Area and a Height of Only 5.2 mm Subminiature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density mounting. Low profile of 5.2 mm and weight of only 0.7 g combine to improve mounting efficiency. Models with inside-L surface mounting terminals are available. Consumes approximately 70% the power of a conventional OMRON model and operates at a current that is as low as 100 mW. Surface mounting terminal models incorporate a unique terminal structure with high infrared irradiation efficiency which allows the terminal temperature to rise easily when mounting the IRS, thus ensuring excellent soldering. Ensures a dielectric strength of 1,500 VAC and conforms to FCC Part 68 (i.e., withstanding an impulse withstand voltage of 1,500 V for 10 x 160 !s). New-Y models offer an impulse withstand voltage of 2,500 V for 2 x 10 !s (conforms to Bellcore specifications) by optimizing the distance between coil and contacts. Conforms to UL1950 (File No. E41515)/CSA C22.2 No. 950 (File No. LR24825) RC The above specifications are ensured as of August 1999. Ordering Information Classification DPDT Note: Fully y sea sealed ed Single-side stable Single-winding latching Single-side stable Bellcore: 2, 500 V for 2x10 !s Through-hole terminal G6K-2P G6KU-2P-Y G6K-2P-Y S ace mounting Surface o g t terminal i l Inside-L G6K-2G G6KU-2G-Y G6K-2G-Y Outside-L G6K-2F G6KU-2F-Y G6K-2F-Y 1. When ordering, add the rated coil voltage to the model number. Example: G6K-2F 12 VDC Rated coil voltage 2. When ordering tape packing, add "-TR" to the model number. Example: G6K-2F-TR 12 VDC Tape packing Be sure since "-TR" is not part of the relay model number, it is not marked on the relay case. Model Number Legend G6Kj-jj-j j VDC 1 1. 2 3 4 5 Relay function None: Single-side stable model U: Single-winding latching model 2. Contact form 2: DPDT 3. Terminal shape F: Outside-L surface mounting terminal G: Inside-L surface mounting terminal P: PCB terminal 4. Approved standards None: UL, CSA Does not conform to Bellcore specifications Y: UL, CSA Conforms to Bellcore specifications: 2,500 V for 2 x 10 !s 5. Rated Coil Voltage 3, 4.5, 5, 12, 24 VDC 1 G6K G6K Application Examples Telephones, communications equipment, measurement devices, office automation machines, and audio-visual products. Specifications Contact mechanism: Bifurcated crossbar Ag (Au-alloy contact) Enclosure ratings: Fully sealed Coil Ratings Single-side Stable Models G6K-2F, G6K-2G, G6K-2P Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC Rated current 33.0 mA 23.2 mA 21.1 mA 9.1 mA Coil resistance 91 " 194 " 237 " 1,315 " Must operate voltage 80% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 150% of rated voltage at 23#C to 70#C Power consumption Approx. 100 mW Note: 1. The rated current and coil resistance are measured at a coil temperature of 23#C with a tolerance of $10%. 2. The operating characteristics are measured at a coil temperature of 23#C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously. Single-side Stable Models (Bellcore Version) G6K-2F-Y, G6K-2G-Y, G6K-2P-Y Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC Rated current 33.0 mA 23.2 mA 21.1 mA 9.1 mA 4.6 mA Coil resistance 91 " 194 " 237 " 1,315 " 5,220 " Must operate voltage 80% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 150% of rated voltage at 23#C to 70#C Power consumption Approx. 100 mW Note: 2 1. The rated current and coil resistance are measured at a coil temperature of 23#C with a tolerance of $10%. 2. The operating characteristics are measured at a coil temperature of 23#C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously. G6K G6K Single-winding Latching Models (Bellcore Version) G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC Rated current 33.0 mA 23.2 mA 21.1 mA 9.1 mA 4.6 mA Coil resistance 91 " 194 " 237 " 1,315 " 5,220 " Must set voltage 75% max. of rated voltage Must reset voltage 75% max. of rated voltage Max. voltage 150% of rated voltage at 23#C to 70#C Power consumption Approx. 100 mW Note: 1. The rated current and coil resistance are measured at a coil temperature of 23#C with a tolerance of $10%. 2. The operating characteristics are measured at a coil temperature of 23#C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously. Contact Ratings Load Resistive load Rated load 0.3 A at 125 VAC; 1 A at 30 VDC Rated carry current 1A Max. switching voltage 125 VAC, 60 VDC Max. switching current 1A Characteristics Single-side stable models (double-pole) Item G6K-2F, G6K-2G, G6K-2P G6K-2F-Y, G6K-2G-Y, G6K-2P-Y Single-winding latching model G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y Contact resistance (see note 1) 100 m" max. Operating (set) time (see note 2) 3 ms max. (approx. 1.4 ms) 3 ms max. (approx. 1.2 ms) Release (reset) time (see note 2) 3 ms max. (approx. 1.3 ms) 3 ms max. (approx. 1.2 ms) Insulation resistance (see note 3) 1,000 M" min. (at 500 VDC) Dielectric strength t th 1,500 VAC, 50/60 Hz for 1 min Impulse p withstand ith t d voltage Coil and contacts Contacts of different 1,000 VAC, 50/60 Hz for 1 min polarity Contacts of same polarity 750 VAC, 50/60 Hz for 1 min Coil and contacts 1,500 V (10 x 160 !s) 2,500 V (2 x 10 !s), 1,500 V (10 x 160 !s) Contacts of different 1,500 V (10 x 160 !s) polarity Contacts of same polarity Vibration resistance Destruction: 10 to 55 Hz, 5-mm double amplitude and 55 to 500 Hz, 300 m/s2 (approx. 30G) Malfunction: 10 to 55 Hz, 3.3-mm double amplitude and 55 to 500 Hz, 200 m/s2 (approx. 20G) Shock resistance Destruction: 1,000 ms2 (approx. 100G) Malfunction: 750 ms2 (approx. 75G) Life expectancy Mechanical: 50,000,000 operations min. (at 36,000 operations/hour) Electrical: 100,000 operations min. (with a rated load at 1,800 operations/hour) Failure rate (P level) (see note 4) 10 !A at 10 mVDC Ambient temperature Operating: Storage: --40#C to 70#C (with no icing or condensation) --40#C to 70#C (with no icing or condensation) Ambient humidity Operating: 35 to 85% Weight Approx. 0.7 g Note: The above values are initial values. Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method. 2. Values in parentheses are actual values. 3. The insulation resistance was measured with a 500-VDC megger applied to the same parts as those used for checking the dielectric strength. 4. This value was measured at a switching frequency of 120 operations/min. 3 G6K G6K Ambient Temperature vs. Switching Current Switching current (A) AC resistive load DC resistive load Ambient Temperature vs. Maximum Coil Voltage Note: 125 VAC resistive load Ambient temperature: 23#C Switching frequency: 1,800 operations/hour Ambient Temperature vs. Must Operate or Must Release Voltage Ambient Temperature vs. Must Set or Must Reset Voltage G6K-2G (F/P), G6K-2G (F/P)-Y G6KU-2G (F/P)-Y Max. estimated value Must operate voltage Must release voltage Ambient temperature (#C) Switching current (A) Energized Not energized Shock direction Unit: m/s2 Sample: G6K-2G Number of Relays: 10 Conditions: Shock is applied in $X, $Y, and $Z directions three times each with and without energizing the Relays to check the number of contact malfunctions. 4 Electrical Life Expectancy (with Must Operate and Must Release Voltage) (see note) Max. estimated value Ambient temperature (#C) Electrical Life Expectancy (Contact Resistance) (see note) G6K-2G (F/P), G6K-2G (F/P)-Y G6K-2G (F/P), G6K-2G (F/P)-Y On the basis of rated voltage (%) Shock Malfunction On the basis of rated voltage (%) 30 VDC resistive load Ambient temperature: 23#C Switching frequency: 1,800 operations/hour The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. On the basis of rated voltage (%) Switching operations (x104 operations) Life Expectancy Ambient temperature (#C) Ambient temperature (#C) Switching voltage (V) Sample: G6K-2G Number of Relays: 10 Test conditions: 1 A resistive load at 30 VDC with an operation rate of 50% Switching frequency: 1,800 operations/h Must operate Contact resistance (m" ) Switching current (A) Maximum Switching Power Maximum coil voltage (%) Engineering Data Sample: G6K-2G Number of Relays: 10 Test conditions: 1 A resistive load at 30 VDC with an operation rate of 50% Switching frequency: 1,800 operations/h NO contact NC contact Contact resistance Must release Operating frequency (x103 operations) Operating frequency (x103 operations) G6K G6K Contact Reliability Test (see note) Mutual Magnetic Interference Mutual Magnetic Interference G6K-2G (F/P), G6K-2G (F/P)-Y G6K-2G (F/P), G6K-2G (F/P)-Y G6K-2G (F/P), G6K-2G (F/P)-Y Not energized Sample Energized Test Initial stage Sample Not energized Average value Initial stage Change rate on the basis of initial value (%) Sample Initial stage Must operate voltage Must release voltage Test Sample Energized Average value Change rate on the basis of initial value (%) NO contact NC contact Change rate on the basis of initial value (%) Sample: G6K-2G Number of Relays: 10 Test conditions: 10 !A resistive load at 10 mVDC with an operation rate of 50 % Switching frequency: 7,200 operations/h Change rate on the basis of initial value (%) Contact resistance (m" ) Must operate voltage Must release voltage Test Average value Initial stage Test Average value Operating frequency (x103 operations) Note: The test was conducted at an ambient temperature of 23#C. (Average value) Sample: G6K-2G Number of Relays: 10 Must operate voltage Must release voltage External magnetic field (A/m) (Average value) Sample: G6K-2G Number of Relays: 10 Must operate voltage Must release voltage External magnetic field (A/m) Change rate on the basis of initial value (%) G6K-2G (F/P), G6K-2G (F/P)-Y Change rate on the basis of initial value (%) Change rate on the basis of initial value (%) External Magnetic Interference (Average value) Sample: G6K-2G Number of Relays: 10 Must operate voltage Must release voltage External magnetic field (A/m) High-frequency Characteristics High-frequency Characteristics High-frequency Characteristics (Isolation) G6K-2G (F/P), G6K-2G (F/P)-Y (Insertion Loss) G6K-2G (F/P), G6K-2G (F/P)-Y (Return Loss) G6K-2G (F/P),G6K-2G (F/P)-Y (Average value) (Average value) Return loss (dB) Insertion loss (dB) Isolation (dB) (Average value) Sample: G6K-2G Number of Relays: 10 Sample: G6K-2G Number of Relays: 10 Sample: G6K-2G Number of Relays: 10 Return loss Frequency (MHz) Frequency (MHz) Frequency (MHz) 5 G6K Must Operate and Must Release Vibration Resistance Bounce Time Distribution (see note) G6K-2G (F/P), G6K-2G (F/P)-Y G6K-2G (F/P), G6K-2G (F/P)-Y G6K-2G (F/P) , G6K-2G (F/P)-Y Number of contacts Sample: G6K-2G Number of Relays: 50 Must operate Must release time Must operate bounce time Must release bounce time Sample: G6K-2G Number of Relays: 50 Note: Time (ms) Time (ms) The tests were conducted at an ambient temperature of 23#C. Change rate on the basis of rated value (%) Must Operate and Must Release Time Distribution (see note) Number of contacts G6K Must operate voltage Must release voltage After test Dimensions Note: All units are in millimeters unless otherwise indicated. DPDT Mounting Dimensions (Top View) Tolerance: $0.1 mm G6K-2F Note: Each value has a tolerance of $0.3 mm. Mounting Dimensions (Top View) Tolerance: $0.1 mm G6K-2G Note: Each value has a tolerance of $0.3 mm. Terminal Arrangement/ Internal Connections (Top View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) Orientation mark Mounting Dimensions (Bottom View) Terminal Arrangement/ Tolerance: $0.1 mm Internal Connections Eight, 0.8-dia. holes (Bottom View) G6K-2P Orientation mark Note: 6 Each value has a tolerance of $0.3 mm. G6K G6K Mounting Dimensions (Top View) Tolerance: $0.1 mm G6K-2F-Y Terminal Arrangement/ Internal Connections (Top View) Orientation mark Note: G6K-2G-Y Each value has a tolerance of $0.3 mm. Mounting Dimensions (Top View) Tolerance: $0.1 mm Terminal Arrangement/ Internal Connections (Top View) Orientation mark Note: Each value has a tolerance of $0.3 mm. G6K-2P-Y Mounting Dimensions (Bottom View) Terminal Arrangement/ Tolerance: $0.1 mm Internal Connections Eight, 0.8-dia. holes (Bottom View) Orientation mark Note: Each value has a tolerance of $0.3 mm. G6KU-2F-Y Note: Each value has a tolerance of $0.3 mm. Note: Each value has a tolerance of $0.3 mm. G6KU-2G-Y G6KU-2P-Y Mounting Dimensions (Top View) Tolerance: $0.1 mm Terminal Arrangement/ Internal Connections (Top View) Mounting Dimensions (Top View) Tolerance: $0.1 mm Terminal Arrangement/ Internal Connections (Top View) Orientation mark Orientation mark Mounting Dimensions (Bottom View) Terminal Arrangement/ Tolerance: $0.1 mm Internal Connections Eight, 0.8-dia. holes (Bottom View) Orientation mark Note: Each value has a tolerance of $0.3 mm. 7 G6K G6K Stick Packing and Tape Packing Stick Packing Relays in stick packing are arranged so that the orientation mark of each Relay in on the left side. Fifty Relays are packed on one stick. Be sure not to make mistakes in Relay orientation when mounting the Relay to the PCB. Orientation of Relays Stopper (gray) Stopper (green) Stick length: 520 mm (stopper not included) No. of Relays per stick: 50 Tape Packing (Surface Mounting Terminal Models) When ordering Relays in tape packing, add the prefix "-TR" to the model number, otherwise the Relays in stick packing will be provided. Tape Type: ETX7200 (EIAJ (Electronic Industrial Association of Japan)) Reel type: RPM-16D (EIAJ) Relays per Reel: 900 1. Direction of Relay Insertion Pulling direction 3. Carrier Tape Dimensions G6K-2F, G6K-2F-Y, G6KU-2F-Y Orientation mark Top tape (cover tape) Pulling direction Carrier tape 2. Reel Dimensions 8 Emboss tape G6K-2G, G6K-2G-Y, G6KU-2G-Y G6K G6K Recommended Soldering Method Temperatures indicate the surface temperatures of the PCB. Temperature ( C) IRS Method (for surface mounting terminal models) # Soldering Preheating Time (s) % The thickness of cream solder to be applied should be within a range between 150 and 200 !m on OMRON's recommended PCB pattern. % In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the left-hand side. Correct Soldering Incorrect Soldering Relay Insufficient amount of solder Terminal Solder Land PCB Excessive amount of solder Visually check that the Relay is properly soldered. Approved Standards UL approval: UL1950 (File No. E41515) CSA approval: C22.2 No. 950 (File No. LR24825) Contact form DPDT Coil rating G6K-2G(F/P): 3 to 12 VDC G6K(U)-2G(F/P)-Y: 3 to 24 VDC Contact rating 1 A at 30 VDC 0.5 A at 60 VDC 0.3 A at 125 VAC Number of test operations 6,000 9 G6K G6K Precautions For general precautions, refer to the PCB Relays Catalog (X033). Familiarize yourself with the precautions and glossary before using the G6K. Correct Use Handling Leave the Relay unpacked until mounting it. Soldering Solder: JIS Z3282, H63A Soldering temperature: Approx. 250#C (260#C if the DWS method is used) Soldering time: Approx. 5 s max. (approx. 2 s for the first time and approx. 3 s for the second time if the DWS method is used) Be sure to make a molten solder level adjustment so that the solder will not overflow on the PCB. Claw Securing Force During Automatic Mounting During automatic insertion of Relays, make sure to set the securing force of each claw to the following so that the Relays characteristics will be maintained. Direction A: 1.96 N Direction B: 4.90 N Direction C: 1.96 N Environmental Conditions During Operation, Storage, and Transportation Protect the Relay from direct sunlight and keep the Relay under normal temperature, humidity, and pressure. If the Relay is stored for a long time in an adverse environment with high temperature, high humidity, organic gases, or sulfide gases, sulfide or oxide films will form on the contact surfaces. These films may result in unstable contact, contact problems, or functional problems. Therefore, operate, store, or transport the product under specified environmental conditions. Latching Relay Mounting Make sure that the vibration or shock that is generated from other devices, such as relays in operation, on the same panel and imposed on the Latching Relay does not exceed the rated value, otherwise the Latching Relay that has been set may be reset or vice versa. The Latching Relay is reset before shipping. If excessive vibration or shock is imposed, however, the Latching Relay may be set accidentally. Be sure to apply a reset signal before use. Maximum Allowable Voltage The maximum allowable voltage of the coil can be obtained from the coil temperature increase and the heat-resisting temperature of coil insulating sheath material. (Exceeding the heat-resisting temperature may result in burning or short-circuiting.) The maximum allowable voltage also involves important restrictions which include the following: % Must not cause thermal changes in or deterioration of the insulating material. % Must not cause damage to other control devices. % Must not cause any harmful effect on people. % Must not cause fire. Therefore, be sure to use the maximum allowable voltage beyond the value specified in the catalog. As a rule, the rated voltage must be applied to the coil. A voltage exceeding the rated value, however, can be applied to the coil provided that the voltage is less than the maximum allowable voltage. It must be noted that continuous voltage application to the coil will cause a coil temperature increase thus affecting characteristics such as electrical life and resulting in the deterioration of coil insulation. Coating The Relay mounted on the PCB may be coated or washed but do not apply silicone coating or detergent containing silicone, otherwise the silicone coating or detergent may remain on the surface of the Relay. PCB Mounting If two or more Relays are closely mounted with the long sides of the Relays facing each other and soldering is performed with infrared radiation, the solder may not be properly exposed to the infrared rays. Be sure to keep the proper distance between adjacent Relays as shown below. G6K-2G 2 mm min. G6K-2F 2.7 mm min. Two or more Relays may be closely mounted with the short sides of the Relays facing each other. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K106-E1-3A 10