RHRG1560CC, RHRG1540CC
www.onsemi.com
2
ABSOLUTE MAXIMUM RATINGS (TJ = 25°C, unless otherwise specified) (Per Leg)
Description Symbol RHRG1560CC RHRG1540CC Unit
Peak Repetitive Reverse Voltage VRRM 600 400 V
Working Peak Reverse Voltage VRWM 600 400 V
DC Blocking Voltage VR600 400 V
Average Rectified Forward Current (TC = 140°C) IF(AV) 15 15 A
Repetitive Peak Surge Current (Square Wave, 20 kHz) IFRM 30 30 A
Non−repetitive Peak Surge Current (Halfwave, 1 Phase, 60 Hz) IFSM 200 200 A
Maximum Power Dissipation PD100 100 W
Avalanche Energy (See Figures 10 and 11) EAVL 20 20 mJ
Operating and Storage Temperature TSTG, TJ−65 to 175 −65 to 175 °C
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
PACKAGE MARKING AND ORDERING INFORMATION
Part Number Top Mark Package Shipping
RHRG1560CC RHRG1560C TO−247−3L 450 / Tube
RHRG1540CC RHRG1540C TO−247−3L 450 / Tube
ELECTRICAL SPECIFICATIONS (TJ = 25°C, unless otherwise specified) (Per Leg)
Characteristic Symbol Test Conditions
RHRG1560CC RHRG1540CC Unit
Min Typ Max Min Typ Max Unit
Instantaneous Forward Voltage
(Pulse Width = 300 ms,
Duty Cycle = 2%)
VFIF = 15 A − − 2.1 − − 2.1 V
IF = 15 A, TC = 150°C− − 1.7 − − 1.7 V
Instantaneous Reverse Current IRVR = 400 V − − − − − 100 mA
VR = 600 V − − 100 − − − mA
VR = 400 V, TC = 150°C− − − − − 500 mA
VR = 600 V, TC = 150°C− − 500 − − − mA
Reverse Recovery Time
(See Figure 9),
Summation of ta + tb.
Trr IF = 1 A, dIF/dt = 100 A/ms− − 35 − − 35 ns
IF = 15 A, dIF/dt = 100 A/ms− − 40 − − 40 ns
Time to Reach Peak Reverse
Current (See Figure 9).
taIF = 15 A, dIF/dt = 100 A/ms−20 − − 20 −ns
Time from Peak IRM to Projected
Zero Crossing of IRM Based on
a Straight Line from Peak IRM
through 25% of IRM
(See Figure 9).
tbIF = 15 A, dIF/dt = 100 A/ms−15 − − 15 −ns
Reverse Recovery Charge Qrr IF = 15 A, dIF/dt = 100 A/ms−40 − − 40 −nC
Junction Capacitance CJVR = 10 V, IF = 0 A −60 − − 60 −pF
Thermal Resistance Junction
to Case
RqJC − − 1.5 − − 1.5 °C/W
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.