Thermal Automotive Circuit Breaker 1170-... Description Compact single pole thermal circuit breaker with push-to-reset, tease free, trip free, snap action mechanism and separate (colour coded) manual release. Combining full feature circuit breaker protection and convenience with low cost of ownership benefits. Fitted with blade terminals for plug-in mounting. Type III to SAE J 553. 1 Typical applications Extra low voltage wiring systems on all types of vehicles and marine craft. 1170-... Ordering information Technical data Type No. 1170 plug-in Design standard 01 blade terminals for automotive fuse blocks (standard) with retaining clips 02 blade terminals for automotive fuse blocks, without retaining clips 21 as design 01 but with higher interrupting capacity 22 as design 02 but with higher interrupting capacity Current ratings 3...25 A 1170 - 01 - 15 A Voltage rating Current ratings Typical life Ambient temperature Interrupting capacity Icn Ultimate short-circuit breaking capacity Degree of protection (IEC 60529/DIN 40050) Vibration 3 or 4 A: 5...25 A: ordering example Standard current ratings, typical voltage drop values and actuator colours (manual release) Current rating (A) 3 4 5 6 7.5 8 10 15 20 25 06/07 Voltage drop (mV) < 300 < 300 < 150 < 150 < 150 < 150 < 150 < 150 < 150 < 150 Shock Actuator colour violet pink orange-brown mossy-green hazel honey red blue yellow pearl (approximating (approximating (approximating (approximating (approximating (approximating (approximating (approximating (approximating (approximating RAL RAL RAL RAL RAL RAL RAL RAL RAL RAL DC 28 V 3...25 A (30 A upon request) 6,000 operations at IN 3,000 operations at 2 x IN 20 A 1,000 operations at 2 x IN 25 A -30...+60 C (-22...+140 F) 3...15 A 200 A (1170-01/-02) 3...15 A 400 A (1170-21/-22) 20...25 A 400 A 4008) 3015) 8023) 6005) 8011) 1005) 3020) 5012) 1018) 1013) Corrosion Humidity Mass www.e-t-a.com 1 break operation at 2000 A operating area IP40 terminal area IP00 8 g (57-500 Hz) 0.65mm (10-57 Hz) 10 g (57-500 Hz)0.76 mm (10-57 Hz), to IEC 60068-2-6, test Fc, 10 frequency cycles/axis 3 or 4 A: 35 g (11 ms) 5...25 A: 50 g (11 ms) to IEC 60068-2-27, test Ea 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka 240 hours at 95 % RH to IEC 60068-2-3, test Ca approx. 13 g 1 - 37 Thermal Automotive Circuit Breaker 1170-... Dimensions Internal connection diagram 1 ON OFF 1170-01/-21 3 .118 7 .276 o4 .157 2 6.4 .252 7.6 .299 38 1.50 3 .118 1 Typical time/current characteristics at +23C7+73.4F max. 9.8 max .386 5.2 .205 14.5 .571 18.8 .740 3.6 .142 terminal area to DIN 72581 part 3 0.6 .024 4.2 .165 10000 20 +23 C +73.4 F -30 C -22 F 1170-02/-22 ON 3 .118 7 .276 o4 .157 Trip time in seconds 1000 current rating without A OFF +60 C +140 F 22 .866 100 7.6 .299 38 1.50 3 .118 10 6.4 .252 1 max. 9.8 max .386 5.2 .205 14.5 .571 18.8 .740 terminal area to DIN 72581 part 3 20 22 .866 current rating without A 3.6 .142 0.1 0.6 .024 1 2 4 6 8 10 ... times rated current 20 40 4.2 .165 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 - Technical information. Ambient temperature F -22 -4 +14 +32 +73.4 +104 +122 +140 C -30 -20 -10 0 +23 +40 +50 +60 Derating factor 0.8 0.76 0.84 0.92 1 1.08 1.16 1.24 This is a metric design and millimeter dimensions take precedence ( mm ) inch 1 - 38 www.e-t-a.com 06/07 Thermal Automotive Circuit Breaker 1170-... Accessories Ordering information Mounting socket 12 Socket 12-P10 30.3 1.19 25.4 1.00 Weidmuller style label (not supplied) 3.5 .138 47 1.85 43 1.69 blade terminal DIN 46244-A6.3-0.8 (QC .250) 58 2.28 Type No. 12 Mounting socket Terminal design P10 blade terminals A 6.3-0.8 (QC .250) J20 screw terminals 6-32 UNC A10 1 blade terminal A6.3-0.8 (QC .250)/1 screw terminal 6-32 UNC Version (blank) single socket 20 two-way 30 three-way 40 four-way 60 six-way 12 - P10 - 20 ordering example 48.4 1.91 o3.9 .154 12.7 .500 symmetrical hat rail EN 50022-35x7.5 Accessories for mounting socket 12 Socket 12-J20 30.3 1.19 25.4 1.00 Weidmuller style label (not supplied) terminal screw 6-32 UNC Connector bus links -P10 X 210 588 01/ 1.5 mm2 (AWG 16), brown (up to 13 A max. load) X 210 588 02/ 2.5 mm2 (AWG 14), black (up to 20 A max. load) X 210 588 03/ 2.5 mm2 (AWG 14), red (up to 20 A max. load) X 210 588 04/ 2.5 mm2 (AWG 14), blue (up to 20 A max. load) 3.5 .138 47 1.85 43 1.69 spring washer ~70 ~2.76 58 2.28 100 quick-connect tabs 6.3 (.250) DIN 46247 tinned brass, insulated 12.7 .500 symmetrical hat rail EN 50022-35x7.5 Bus bar (supplied as a complete package) (up to 100 A max. load) X 211 157 01 with terminal X 211 157 02 without terminal 30.3 1.19 25.4 1.00 washer A 4.3 DIN 125 nickel plated cylinder head screw ISO1207-M4x4 nickel plated blade terminal DIN 46244-A6.3-0.8 (QC .250) 3.5 .138 7 .276 58 2.28 Cu rail, tin-plated M4 symmetrical hat rail EN 50022-35x7.5 12.8 .504 154.8 6.09 fusible link 1.1mm (.043 in.) thick constriction) 48.4 1.91 o3.9 .154 12.7 .500 spring washer Phoenix terminal AKG 35 max.cross section 35 mm2 (AWG 2) Weidmuller style label (not supplied) 47 1.85 43 1.69 terminal screw 6-32 UNC 2 .079 Socket 12-A10 10 .394 o3.9 .154 48.4 1.91 Dimensions for surface mounting 7 48.4 1.91 .276 13 .512 o4 .157 60 2.36 Other sockets available to special order Labels: Weidmuller, D-33102 Paderborn This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 06/07 www.e-t-a.com 1 - 39 1