2www.irf.com
IRHNA7160, JANSR2N7432U Pre-Irradiation
Electrical Characteristics @ Tj = 25°C (Unless Otherwise Specified)
Parameter Min Typ Max Units Test Conditions
BVDSS Drain-to-Source Breakdown Voltage 100 — — V VGS =0 V, ID = 1.0mA
∆BVDSS/∆TJTemperature Coefficient of Breakdown — 0.11 — V/°C Reference to 25°C, ID = 1.0mA
Voltage
RDS(on) Static Drain-to-Source — — 0.040 VGS = 12V, ID = 32.5A
On-State Resistance — — 0.045 ΩVGS = 12V, ID = 51A
VGS(th) Gate Threshold Voltage 2.0 — 4.0 V VDS = VGS, ID = 1.0mA
gfs Forward Transconductance 16 — — S ( )V
DS > 15V, IDS = 32.5A
IDSS Zero Gate Voltage Drain Current — — 25 VDS= 80V,VGS=0V
— — 250 VDS = 80V
VGS = 0V, TJ = 125°C
IGSS Gate-to-Source Leakage Forward — — 100 VGS = 20V
IGSS Gate-to-Source Leakage Reverse — — -100 VGS = -20V
QgTotal Gate Charge — — 310 VGS = 12V, ID = 51A
Qgs Gate-to-Source Charge — — 53 nC VDS = 50V
Qgd Gate-to-Drain (‘Miller’) Charge — — 110
td(on) Turn-On Delay Time — — 35 VDD = 50V, ID = 51A,
trRise Time — — 150 VGS = 12V, RG = 2.35Ω
td(off) Turn-Off Delay Time — — 150
tfFall Time — — 130
LS + LDTotal Inductance — 4.0 —
Ciss Input Capacitance — 5300 — VGS = 0V, VDS = 25V
Coss Output Capacitance — 1600 — pF f = 1.0MHz
Crss Reverse Transfer Capacitance — 350 —
nA
Ω
nH
ns
µA
Note: Corresponding Spice and Saber models are available on the International Rectifier Website.
For footnotes refer to the last page
Thermal Resistance
Parameter Min Typ Max Units Test Conditions
RthJC Junction-to-Case — — 0.42
RthJPCB Junction-to-PC Board — 1.6 — Solder to a 1” sq. copper clad PC Board
°C/W
Source-Drain Diode Ratings and Characteristics
Parameter Min Typ Max Units Test Conditions
ISContinuous Source Current (Body Diode) — — 51
ISM Pulse Source Current (Body Diode) À— — 204
VSD Diode Forward Voltage — — 1.8 V Tj = 25°C, IS = 51A, VGS = 0V Ã
trr Reverse Recovery Time — — 520 ns Tj = 25°C, IF = 51A, di/dt ≥ 100A/µs
QRR Reverse Recovery Charge — — 6.5 µC VDD ≤ 50V Ã
ton Forward Turn-On Time Intrinsic turn-on time is negligible. Turn-on speed is substantially controlled by LS + LD.
A
Measured from center of drain
pad to center of source pad