IMS6 Series Data Sheet, 6-Watt DC-DC Converters Input to output electric strength test up to 2 kVDC Input voltage ranges: 18 to 36 and 36 to 75 VDC Single and dual outputs of 5, 12, & 15 VDC Features * RoHS lead-solder-exempt compliant * Wide input voltage ranges * Rated to Basic Isolation * Electrical isolation, single and dual outputs * Immunity to IEC/EN 61000-4-2, -3, -4, and -6 * High efficiency (typ. 84%) * Flex power: flexible load distribution * No load and short-circuit proof * High reliability and no derating * Operating ambient temperature -40 to +71 C 20 0.8" 8.5 0.34" * Industrial and alternative pinouts * DIL 24 case with 8.5 mm profile 32 1.25" Safety according to IEC/EN 60950, UL 1950 Description The IMS6 Series of board-mountable 6 Watt DC-DC converters has been designed according to the latest industry requirements and standards. The converters are particularly suitable for use in mobile or stationary applications in transport, industry or telecommunications where variable input voltages or high transient voltages are prevalent. Covering a total input voltage range from 18 VDC up to 75 VDC, with single and dual outputs from 5 VDC up to 15 VDC with flexible load distribution on dual outputs. The converters are designed and built according to the international safety standards IEC/EN 60950, UL 1950, CAN/CSA C22.2 No.950-95 and are UL marked. Table of Contents A special feature is their small case size, DIL 24 with only an 8.5 mm profile. The circuit comprises integrated planar magnetics and all components are automatically assembled and solidly soldered onto a single PCB without any wire connections. Thanks to the rigid mechanical design, the converters withstand an extremely high level of shock and vibrations. Careful considerations of possible thermal stresses ensure the absence of hot spots providing long life in environments where temperature cycles are a reality. The thermal design allows operation at full load up to an ambient temperature of 71 C in free air without using any potting material. Option:- K-pinout, an alternative to the standard industrial pinout, provides a high level of application specific engineering and design-in flexibility. Page Page Description ....................................................................... 1 Model Selection ............................................................... 2 Part Number Description .................................................. 2 Functional Description ..................................................... 3 Electrical Input Data ......................................................... 4 Electrical Output Data ...................................................... 5 Thermal considerations .................................................... 6 Mechanical Data .............................................................. 7 Electromagnetic Compatibility (EMC) .............................. 7 Immunity to Environmental Conditions ............................. 8 Safety and Installation Instructions .................................. 9 Description of Options .................................................... 10 MCD10106 Rev. 1.0, 27-FEB-09 Page 1 of 10 www.power-one.com IMS6 Series Data Sheet, 6-Watt DC-DC Converters Model Selection Table 1: Model Selection Output 1 Uo1 nom Io1 nom [VDC] [A] 1 1 2 Output 2 Uo2 nom Io2 nom [VDC] [A] 1 Output Power Po nom [W] Input voltage range [VDC] Efficiency typ Options2 Type designation [%] 5 5 12 12 15 15 1000 1000 500 500 400 400 - - 5.0 5.0 6.0 6.0 6.0 6.0 18...36 36...75 18...36 36...75 18...36 36...75 82 82 83 83 84 84 24IMS6-05-9 48IMS6-05-9 24IMS6-12-9 48IMS6-12-9 24IMS6-15-9 48IMS6-15-9 +5 +5 500 500 -5 -5 500 500 5.0 5.0 18...36 36...75 82 82 24IMS6-0505-9 48IMS6-0505-9 +12 +12 250 250 -12 -12 250 250 6.0 6.0 18...36 36...75 83 83 24IMS6-1212-9 48IMS6-1212-9 +15 +15 200 200 -15 -15 200 200 6.0 6.0 18...36 36...75 84 84 24IMS6-1515-9 48IMS6-1515-9 Z Z Flexible load distribution on double outputs possible. Not all -K/-Z options exist, to check if option exists and/orfor minimum quantity and lead time contact Power-One. Part Number Description 24 IMS 6 - 12 12 -9 K Z Input voltage range Vi 18 to 36 VDC ............................................. 24 36 to 75 VDC ............................................. 48 Series ......................................................................... IMS6 Output voltage type for output 1 ......................... 05, 12, 15 Output voltage type for output 2 ......................... 05, 12, 15 Operating ambient temperature range TA -40 to 71 C ................................................ -9 Options: Alternative pinout (check availability) .......... K Open frame .................................................. Z Examples: 48IMS6-1212-9Z: DC-DC converter, input voltage range 36 to 75V, 2 outputs providing 12 V, 250 mA, temperature range -40 to 71 C, no case. JUN 14, 2004 revised to JUL 27, 2006 Page 2 of 10 www.power-one.com IMS6 Series Data Sheet, 6-Watt DC-DC Converters Functional Description The IMS6 DC-DC converters are feedback controlled flyback converters using current mode PWM (Pulse Width Modulation). Current limitation is provided by the primary circuit, thus limiting the total output current (Io nom for the single and Io1 nom + Io2 nom for the dual output types). The converter input is protected against transients by means of a suppressor diode. The close magnetic coupling provided by the planar construction ensures very good regulation and allows for flexible load distribution on dual output types. The output voltage is monitored by a separate transformer winding close to the secondary windings and fed back to the control circuit. 03045 03044 Vi+ 22 14 Vo+ Vi+ 22 23 23 14 Vo+ PWM PWM 16 Go 16 Vo- 2 2 Vi- 3 11 Vo- Vi- 3 10 Fig. 1 Block diagram for single output types. Standard industrial pinout. Fig. 2 Block diagram for dual output types. Standard industrial pinout. 03046 Vi+ 1 03047 13 Vo+ 15 Vo+ Vi+ 1 n.c. 2 PWM PWM 10 11 12 Vo- Vi- 24 Fig. 3 Block diagram for single output types. Special pinout (option K). MCD10106 Rev. 1.0, 27-FEB-09 Vi- 24 Go 13 Vo- Fig. 4 Block diagram for dual output types. Special pinout (option K). Page 3 of 10 www.power-one.com IMS6 Series Data Sheet, 6-Watt DC-DC Converters Electrical Input Data General conditions: TA = 25 C, unless TC is specified. Table 2: Input Data Input 1 2 3 24IMS6 Characteristics Conditions min Vi Input voltage range 18 Vi nom Nominal input voltage TC min to TC max Io = 0 to Io nom Vi sur Repetitive surge voltage abs. max input (3 s) t start up Converter start-up t rise Rise time 1 time 1 max min 36 36 typ 24 max Unit 75 V DC 48 40 Worst case condition at Vi min and full load Vi nom Io nom 48IMS6 typ 0.25 100 0.5 0.25 0.5 s ms resistive load 5 5 capacitive load 12 12 Ii o No load input current Io = 0, Vi min to Vi max Ci Input capacitance for surge calculation I inr p Inrush peak current Vi = Vi nom 15 20 3 fs Switching frequency Vi min...Vi max, Io = 0...Io nom I i rr Reflected ripple current Io = 0 to Io nom Vi RFI Input RFI level conducted and radiated EN 55022 2 10 mA 0.54 5 0.3 F 3.7 4.2 A 30 mApp approx. 400 approx. 400 30 B kHz B Measured with a resistive or max. admissible capacitive load. (See fig.: Converter start-up and rise time) External filter required. (See: Filter recommendations for compliance with EN standards) Source impedance according to prETS 300132-2, version 4.3. Vo Vo nom t rise t start up Reverse Polarity Protection at Input The suppressor diode on the input also provides for reverse polarity protection by conducting current in the reverse direction, thus protecting the unit. An external fuse is required to limit this current: 04008 t - For 24IMS6 a fast 1 A (F1A) fuse is recommended - For 48IMS6 a fast 0.63 A (F0.63A) fuse is recommended Fig. 5 Converter start-up and rise time Inrush Current Filter recommendations for compliance with EN 55022 The inrush current has been kept as low as possible by choosing a very small input capacitance. A series resistor may be inserted in the input line to limit this current further. Electromagnetic emission requirements according to table Input data can be achieved by adding an external capacitor as close as possible to the input terminals. 1 A/Div. 4 Ci 3 2 1 0 Vi- Fig. 7 Input filter arrangement Table 3: Input filter components (EN 55022) Ref. C1 MCD10106 Rev. 1.0, 27-FEB-09 5 s/Div. Page 1 of 10 Fig. 6 Type Typical inrush current at Ui nom, Po nom versus time measured according to prETS 300132-2, version 4.3. MCD10106 Rev. 1.0, 27-FEB-09 04035 Vi+ 04034 Page 4 of 10 24IMS6 48IMS6 4.7 F, 63 V, 85C 2.2 F, 100 V, www.power-one.com 85C ceramic or film www.power-one.com IMS6 Series Data Sheet, 6-Watt DC-DC Converters Electrical Output Data General conditions: TA = 25C, unless TC is specified. Table 4a: Output data for single output units Vo nom Output 5V Characteristics Conditions Vo Vi nom, Io = 0.5 Io nom 4.96 Output voltage min Io nom Output current Vi min to Vi max Io L Vi nom, TC = 25C Current limit 2 typ 12 V max min typ 5.04 11.90 1000 15 V max min 12.10 14.88 500 typ max Unit 15.12 VDC 400 mA 1400 700 600 Vo U Line regulation Vi min...Vi max, Io nom 1 1 1 V Vi nom Io = (0.1...1) Io nom 3 3 3 Load regulation Vo1, 2 Output voltage noise Vo clp Output overvoltage limitation Vi min to Vi max I o = I o nom 80 20 Min. load 1 % Co ext Admissible capacitive load 3 Vo d td Vo Dynamic Voltage deviat. Vi nom load Recovery time Io nom x 1/2 Io nom regulat. Temperature coefficient Vo /TC Vi min to Vi max Io = 0 to Io nom 120 40 40 150 60 50 % mVpp 75 130 130 130 % 680 150 100 F 250 250 250 mV 1 1 1 ms 0.02 0.02 0.02 %/K Table 4b: Output data for dual output units Vo nom Output 5 V Characteristics Conditions Vo1 Vo2 Vi nom 4.96 Io1 = Io2 = 0.5 Io nom 4.95 Output voltage Io nom Output current 1 Po L Power limit 23 min typ 5.04 11.90 5.05 11.88 Vi min...Vi max 2 x 500 Vi nom, TC = 25C 2 x 3.5 12.10 14.88 12.12 14.85 2 x 250 max Unit 15.12 15.15 VDC 2 x 200 2 x 4.0 mA 2 x 4.2 W V Vi nom Io = (0.1...1) Io nom 3 3.5 3 Vo 6 typ 1 td 5 min 1 Vo d 4 max 1 Load regulation 4 Vi min...Vi max 5 I o = I o nom 6 100 40 Min. load 1 % Co ext Admissible capacitive load 3 3 15 V typ Vi min...Vi max, Io nom Vo clp Output over voltage limitation 1 min Vo U Line regulation Vo1, 2 Output voltage noise 2 12 V max 140 60 45 70 150 50 % mVpp 75 130 130 130 % 680 150 100 F Dynamic Voltage deviat. load Recovery time regulat. Vi nom Io nom x 1/2 Io nom 250 600 750 mV 1 1 1 ms Temperature coefficient Uo / TC Vi min to Vi max Io = 0 to Io nom 0.02 0.02 0.02 %/K Each output capable of delivering full output power. The current limit is primary side controlled. Sum of both outputs. Conditions for specified output. Other output loaded with constant current Io = 0.5 Io nom. BW = 20 MHz. Measured with a probe according to EN 61204. MCD10106 Rev. 1.0, 27-FEB-09 Page 5 of 10 www.power-one.com IMS6 Series Data Sheet, 6-Watt DC-DC Converters Thermal Considerations Output overvoltage protection If a converter, mounted on a PCB, is located in free, quasistationary air (convection cooling) at the indicated maximum ambient temperature TA max (see table: Temperature specifications) and is operated at its nominal input voltage and output power, the case temperature TC measured at the: Measuring point of case temperature TC (see: Mechanical Data) will approach the indicated value TC max after the warm-up phase. However, the relationship between TA and TC depends heavily on the conditions of operation and integration into a system. The thermal conditions are influenced by input voltage, output current, airflow, temperature of surrounding components and surfaces and the properties of the printed circuit board. TA max is therefore only an indicative value and under practical operating conditions, the ambient temperature TA may be higher or lower than this value. The outputs of the IMS6 converters are protected against overvoltages by Zener diodes. In the event of an overvoltage on the output, the unit will shut down and attempt to restart automatically. The main purpose of this feature is to protect against possible overvoltages which could occur due to a failure in the feedback control circuit. The converters are not designed to withstand external overvoltages applied to the outputs. Caution: The case temperature TC measured at the Measuring point of case temperature TC (see: Mechanical Data) may under no circumstances exceed the specified maximum value. The installer must ensure that under all operating conditions TC remains within the limits stated in the table: Temperature specifications. The outputs of several units with equal nominal output voltage can be connected in parallel. Approximate current sharing between 2 or several units is ensured by their load dependent output characteristic. Typical Performance Curves Vo [V] Connection in series The outputs of single or dual output units can be connected in series without any precautions, taking into consideration that the highest output voltage should remain below 60 V for SELV operation. Connection in parallel Short Circuit Behavior The current limit characteristic shuts down the converter whenever a short circuit is applied to its output. It acts selfprotecting and automatically recovers after removal of the overload condition. Vo1 + Vo2 [V] 05056 5.25 05057 31.5 31 5.0 30.5 4.75 30 4.5 29.5 4.25 4.0 29 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Io [A] Fig. 8 Uo versus Io (typ) of single output units (example for 48IMS6-05-9) 0 20 40 60 80 120 100 140 Io [mA] Fig. 9 Uo versus Io (typ) of dual output units (15 V), with 30 V load connected to Vo+ and Vo-. Vo1 [V] Vo1 , Vo2 [V] 05058 16.5 05059 12.8 16 12.4 15.5 Io2 = 140 mA Io2 = 14 mA 14.5 0 20 40 60 Vo2 Vo1 12 15 14 28.5 11.6 80 100 120 140 Io1 [mA] Fig. 10 Cross load regulation of dual output units. Uo1 versus Io1 (typ) for various Io2 (48IMS6-1515-9). MCD10106 Rev. 1.0, 27-FEB-09 11.2 0 30 60 90 120 150 Io1 [%] Io1 no Fig. 11 Flexible load distribution on dual outputs (2 x 12 V) with load variation from 0 to 150% of Po1 nom on output 1. Output 2 loaded with 25% of Po2 nom. Page 6 of 10 www.power-one.com IMS6 Series Data Sheet, 6-Watt DC-DC Converters [%] 05060 90 Vo [%] overload short circuit condition 100 Vi nom Vi max Vi min 80 05041 70 switch-off 70 60 8.5 60.5 50 t [ms] 60.5 40 Fig. 12 Overload switch-off (hiccup mode). Frequency of pulses: 16.5 Hz, puls duration: 8.5 ms. 50 25 100 75 Fig. 13 Efficiency versus input voltage and load. Typical values (48 IMS 6-1212-9). Po1 [%] Po nom Electromagnetic Emission Conducted RFI noise at input according to EN 55022 [dBV] 90 Radiated RFI noise according to EN 55022. [dBV/m] 50 07033 80 07034 EN 55022 A 70 40 EN 55022 B 60 50 EN 55022 B 30 40 30 20 20 10 10 20 30 1000 500 200 100 0 50 Fig. 14 Typical disturbance voltage (quasi-peak) at the input according to CISPR 11/EN 55011 and CISPR 22/EN 55022, measured at Ui nom and Io nom. Output leads 0.1 m, twisted. External capacitor at the input required (see: Recommendations for compliance with EN 55022) (48IMS6-1515-9). 30 5 10 2 1 0.5 0.1 0.05 MHz 0.02 0.01 0 Frequency [MHz] Fig. 15 Typical radio frequency interference voltage at Ui nom, Io nom, measured with an antenna (distance 10 m). Output leads 0.1 m, twisted (48IMS6-1515-9). Mechanical Data 31 (1.22") 11 x 2.54 (0.1") 13 24 12 1 15.24 (0.6") 33 (1.3") Measuring point of case temperature TC 13 24 12 1 20 (0.79") European Projection 11 x 2.54 (0.1") 20 (0.79") 3 (0.12") 3 (0.12") S90004 8.5 (0.33") S09042 0.5 (0.02") 8.5 (0.33") 15.24 (0.6") Dimensions in mm. Tolerances 0.3 mm unless otherwise indicated. 0.5 (0.02") Fig. 16 Standard or alternative pinout Weight: <10 g MCD10106 Rev. 1.0, 27-FEB-09 Fig. 17 Open frame (Option Z) Weight: <10 g Page 7 of 10 www.power-one.com IMS6 Series Data Sheet, 6-Watt DC-DC Converters Immunity to Environmental Conditions Table 5: Environmental testing Test Method Ca Standard Test Conditions Status 40 2 C Damp heat steady state IEC/DIN IEC 60068-2-3 MIL-STD-810D section 507.2 Temperature: Relative humidity: Duration: 93 +2/-3 % 56 days Unit not operating Ea Shock (half-sinusoidal) IEC/EN/DIN EN 60068-2-27 MIL-STD-810D section 516.3 Acceleration amplitude: Bump duration: Number of bumps: 100 gn = 981 m/s2 6 ms 18 (3 each direction) Unit operating Eb Bump (half-sinusoidal) IEC/EN/DIN EN 60068-2-29 MIL-STD-810D section 516.3 Acceleration amplitude: Bump duration: Number of bumps: 40 gn = 392 m/s2 6 ms 6000 (1000 each direction) Unit operating Fc Vibration (sinusoidal) IEC/EN/DIN EN 60068-2-6 Acceleration amplitude: Unit operating Frequency (1 Oct/min): Test duration: 0.35 mm (10 to 60 Hz) 5 gn = 49 m/s2 (60...2000 Hz) 10 to 2000 Hz 7.5 h (2.5 h each axis) Fh Vibration, broad-band random (digital control) IEC/EN 60068-2-64 DIN 40046 part 23 MIL-STD-810D section 514.3 Acceleration spectral density: Frequency band: Acceleration magnitude: Test duration: 0.05 gn2/Hz 10...500 Hz 4.9 gn rms 3 h (1 h each axis) Unit operating Kb Salt mist, cyclic (sodium chloride NaCl solution) IEC/EN/DIN IEC 60068-2-52 Concentration: Duration: Storage: Storage duration: Number of cycles: 5% (30 C) 2 h per cycle 40 C, 93 % rel. humidity 22 h per cycle 3 Unit not operating Table 6: Temperature specifications, valid for air pressure of 800 to 1200 hPa (800 to 1200 mbar) Temperature 1 2 Standard -9 Characteristics Conditions min max Unit TA Ambient temperature 1 Operational 2 - 40 71 C TC Case temperature - 40 95 TS Storage temperature 1 - 40 100 Non operational MIL-STD-810D section 501.2 and 502.2 See Thermal Considerations Table 7: MTBF and device hours M TBF G r o u n d Be n i g n G r o u n d F i xe d G ro u n d M o b i l e MTBF acc. to MIL-HDBK-217F TC = 40 C TC = 40 C TC = 70 C TC = 50 C 48IMS6-05-9 2'651'000 h 349'000 h 124'000 h 119'000 h MCD10106 Rev. 1.0, 27-FEB-09 Page 8 of 10 www.power-one.com IMS6 Series Data Sheet, 6-Watt DC-DC Converters Safety and Installation Instructions Table 8: Pin allocation for standard industrial pinout Installation Instruction Installation of the DC-DC converters must strictly follow the national safety regulations in compliance with the enclosure, mounting, creepage, clearance, casualty, markings and segregation requirements of the end-use application. Connection to the system shall be made via a printed circuit board according to: Mechanical Data. The units should be connected to a secondary circuit. Check for hazardous voltages before altering any connections. Pin Single output units Dual output units 2 Vi- Vi- 3 Vi- Vi- 10 n.c. - 11 - Vo- 14 Vo + Vo+ 16 Vo - Go 22 Vi+ Vi+ 23 Vi+ Vi+ Do not open the module. Ensure that a unit failure (e.g. by an internal short-circuit) does not result in a hazardous condition. See also: Safety of operator accessible output circuit. 10013 24 13 Bottom view 12 1 Fig. 18 Pin numbering Table 9: Pin allocation for K pinout (option K) Pin Single output units Dual output units 1 Vi+ Vi+ 2 n.c. - 10 - Go 11 - Go 12 Vo - - 13 Vo + Vo- 15 - Vo+ 24 Vi- Vi- Input Fuse Standards and approvals To prevent excessive current flowing through the input supply line in case of a short-circuit across the converter input an external fuse should be installed in a non-earthed input supply line. We recommend a fast acting fuse F1A for 24IMS6 and F0.5A for 48IMS6 models. All DC-DC converters are UL recognized according to UL 1950, UL recognized for Canada to CAN/CSA C22.2 No. 950-95 and LGA approved to IEC/EN 60950 standards. Safety of operator accessible output circuits If the output circuit of a DC-DC converter is operator accessible, it shall be an SELV circuit according to IEC/EN 60950 related safety standards The insulation concept table below shows some possible installation configurations, compliance with which causes the output circuit of the DC-DC converter to be an SELV circuit according to IEC/EN 60950 up to a configured output voltage (sum of nominal voltages if in series or +/- configuration) of 46 V. The units have been evaluated for: * Building in * Basic insulation input to output, based on their maximum input voltage * The use in a pollution degree 2 environment * Connecting the input to a secondary circuit which is subject to a maximum transient rating of 1500 V for IMS 6. The DC-DC converters are subject to manufacturing surveillance in accordance with the above mentioned UL, CSA, EN and ISO 9001 standards. However, it is the sole responsibility of the installer to ensure the compliance with the relevant and applicable safety regulations. More information is given in: Technical Information: Safety. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10106 Rev. 1.0, 27-FEB-09 Page 9 of 10 www.power-one.com IMS6 Series Data Sheet, 6-Watt DC-DC Converters Cleaning Agents Table 10: Electric strength test voltages In order to avoid possible damage, any penetration of cleaning fluids has to be prevented, since the power supplies are not hermetically sealed. Characteristic Input - Output IMS6 Electric strength test voltage 1 s Protection Degree The protection degree of the DC-DC converters is IP 30. 1.2 kVrms 1.5 kV DC 1.2 nF Insulation resist. at 500 V DC >100 M Partial discharge extinction voltage Consult factory kV Coupling capacitance Isolation The electric strength test is performed as factory test in accordance with IEC/EN 60950 and UL 1950 and should not be repeated in the field. Power-One will not honor any warranty claims resulting from electric strength field tests. Unit Table 11: Insulation concept leading to an SELV output circuit Conditions Front end Supply voltage Minimum required grade of isolation, to be provided by the AC-DC front end, inclu din g ma ins sup plie d battery charger Mains Basic <250 V AC Double or reinforced 1 2 3 4 5 DC-DC converter Result Maximum DC output voltage fro m th e front end 1 Minimum required safety status of the front end output circuit Measures to achieve the specified safety status of the output circuit Safety status of the DC-DC converter output c irc uit <60 V Earthed SELV circuit 2 Operational insulation, provided by the DC-DC conver ter SELV circuit ELV circuit Input fuse 3 output suppressor diodes 4, and earthed output circuit 2 Earthed SELV circuit Operational insulation, provided by the DC-DC converter SELV circuit >60 V Hazardous voltage secondary circuit <60 V SELV circuit >60 V TNV-2 circuit Basic insulation, based on the maximum input voltage, proDouble or reinforced insuvided by the DC-DC converter lated unearthed hazardous voltage secondary circuit 5 The front end output voltage should match the specified input voltage range of the DC-DC converter. The earth connection has to be provided by the installer according to the relevant safety standard, e.g. IEC/EN 60950. The installer shall provide an approved fuse (type with the lowest rating suitable for the application) in a non-earthed input line directly at the input of the DC-DC converter (see fig.: Schematic safety concept). For UL's purpose, the fuse needs to be UL-listed. See also: Input Fuse. Each suppressor diode should be dimensioned in such a way, that in the case of an insulation fault the diode is able to limit the output voltage to SELV (<60 V) until the input fuse blows (see fig.: Schematic safety concept). Has to be insulated from earth by double or reinforced insulation according to the relevant safety standard, based on the maximum output voltage from the front end. ~ Mains ~ Fuse AC-DC front end Battery 10004 DC-DC converter Earth connection Description of Options + Suppressor diode SELV - Earth connection Fig. 19 Schematic safety concept. Use fuse, suppressor diode and earth connection as per table: Safety concept leading to an SELV output circuit. Table 12: Survey of options Option Function of option Characteristic K Alternative pinout Contact factory for availability Z Open frame All models are available without case MCD10106 Rev. 1.0, 27-FEB-09 Page 10 of 10 www.power-one.com